Valleylab SM

Primary DI
20884521837185
Brand
Valleylab SM
Company
Covidien LP
Model
VSMP10NSB
Device description
Smoke Management Pencil with Edge Blade Electrode Non-sterile Bulk, 10ft
Published
2024-07-22
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true
Single use
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
GEIElectrosurgical, cutting & coagulation & accessories

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
GEIElectrosurgical, Cutting & Coagulation & AccessoriesGeneral, Plastic Surgery2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K240572000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K240572000Valleylab™ SM Smoke Management Pencil with Edge™ Blade Electrode, 10’ (3m) (VSMP10); Valleylab™ SM Smoke Management Pencil with Edge™ Blade Electrode, 15’ (4.6m) (VSMP15); Valleylab™ SM Smoke Management Pencil with Edge™ Blade Electrode, 10’ (3m), Non-Sterile Bulk (VSMP10NSB); Valleylab™ SM Smoke Management Extended Nozzle (for use with 4” (100mm) electrode) (VSMEN4); Valleylab™ SM Smoke Management Extended Nozzle (for use with 6.5” (165mm) electrode) (VSMEN6)Covidien, LLC2024-07-01GEI

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
20884521837185PrimaryGS10
10884521837188Unit of UseGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized table
Source identifierGTIN-14 normalized
2088452183718520884521837185
1088452183718810884521837188

GMDN Terms#

Term, Definition table
TermDefinition
Surgical plume evacuation system tubeA long, hollow cylinder which, as part of a surgical plume evacuation system, is intended to be used to capture, conduct, and exhaust the plume of smoke generated during open surgical procedures in which there is tissue ablation (e.g., laser surgery, electrocautery, electrosurgical diathermy device). This is a single-use device.

Device Sizes#

Type, Value, Unit table
TypeValueUnit
Length3Meter

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Humidity15 Percent (%) Relative Humidity90 Percent (%) Relative Humidity
Handling Environment Temperature-30 Degrees Celsius60 Degrees Celsius
Special Storage Condition, Specify00Keep Dry
Storage Environment Humidity15 Percent (%) Relative Humidity90 Percent (%) Relative Humidity
Storage Environment Temperature10 Degrees Celsius40 Degrees Celsius

Contacts#

Phone, Email table
PhoneEmail
+1(508)261-8000covidien.udi@covidien.com

Regulatory Flags#

DUNS number
058614483
Device count
30
Lot or batch
true
Manufacturing date on label
true
No natural rubber latex
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
10884521072602V-LocVLOCN204L2015-09-02
20884521126852Sofsilk1700022016-09-24
10884521091986NellcorSC-A-I2026-05-25
10884521758803Vascufil8886470311V-22020-07-19
10884521816312McGRATH MAC350-005-0002021-10-21
10884521816329McGRATH MAC350-013-0002021-08-30
10884521816336McGRATH MAC350-017-0002021-10-18
10884521816343McGRATH MAC350-072-0002022-06-13
10884521824317McGRATH MAC350-005-0002022-09-25
10884521824324McGRATH MAC350-013-0002021-10-30
10884521824331McGRATH MAC350-017-0002021-08-26
10884521824348McGRATH MAC350-072-0002023-06-19
10884521850118McGRATH MAC350-005-0002025-04-27
10884521850125McGRATH MAC350-013-0002025-04-27
10884521850132McGRATH MAC350-017-0002025-04-27
10884521850149McGRATH MAC350-072-0002025-04-27
15060272980310McGRATH MAC350-005-0002021-08-02
15060272980327McGRATH MAC350-013-0002022-01-17
15060272980334McGRATH MAC350-072-0002021-04-18
15060272980341McGRATH MAC350-017-0002021-03-27

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
07613327693287MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693294MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693362MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693379MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693386MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693393MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693409MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693416MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693423MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693430MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693447MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693454MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693461MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693478MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693485MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693492MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693508MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693515MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693522MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693539MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693546MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693553MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693560MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693577MalisSTRYKER CORPORATIONGEI2026-02-25
08886479300306RhinAer+ StylusAerin Medical Inc.GEI2025-09-19
07613327556469NeptuneSTRYKER CORPORATIONGEI2025-01-30
07613327548204Neptune SafeAirSTRYKER CORPORATIONGEI2025-01-06
07613327556650NeptuneSTRYKER CORPORATIONGEI2024-12-13
07613327548129NeptuneSTRYKER CORPORATIONGEI2024-12-10
07613327548143NeptuneSTRYKER CORPORATIONGEI2024-12-10