FUJIFILM

Primary DI
24547410138515
Brand
FUJIFILM
Company
FUJIFILM CORPORATION
Model
CA-601
Device description
This product is exclusively used for manual cleaning and manual disinfection of a FUJIFILM endoscope in medical facilities. Do not use this product for any other purpose.
Published
2022-10-07
Public version status
New
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true
OTC
false
Sterile
false
Single use
false

Contact Domains#

Product Codes#

Code, Name table
CodeName
ITXTransducer, ultrasonic, diagnostic

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
ITXTransducer, Ultrasonic, DiagnosticRadiology2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K120446000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K120446000FUJINON/FUJIFILM ULTRASONIC ENDOSCOPE EG-530UR2 AND EG-530UT2Fujinon, Inc.2012-08-13FDS

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
24547410138515PackageGS11In Commercial Distribution
04547410138511PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, EAN-13 table
Source identifierGTIN-14 normalizedEAN-13
2454741013851524547410138515
04547410138511045474101385114547410138511

GMDN Terms#

Term, Definition table
TermDefinition
Luminal device flushing tubing set, reusableA collection of devices which includes connection tubing intended to be fitted to a luminal device (e.g., catheter, endoscope channel, ophthalmic handpiece) to assist flushing the device lumen during a medical/surgical procedure, and/or to assist the washing, disinfection and/or sterilization of the lumen. In addition to tubing, the set includes connectors/valves to allow appropriate fluids (e.g., sterilant, disinfectant) and gases to flow through the device lumen. It may be used in conjunction with a syringe, device washer/disinfector, and/or water tap. This is a reusable device.

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Atmospheric Pressure70 KiloPascal106 KiloPascal
Handling Environment Humidity30 Percent (%) Relative Humidity85 Percent (%) Relative Humidity
Handling Environment Temperature10 Degrees Celsius40 Degrees Celsius
Special Storage Condition, Specify00There must be no condensation.
Storage Environment Atmospheric Pressure70 KiloPascal106 KiloPascal
Storage Environment Humidity10 Percent (%) Relative Humidity85 Percent (%) Relative Humidity
Storage Environment Temperature-20 Degrees Celsius60 Degrees Celsius

Sterilization Methods#

Method table
Method
Ethylene Oxide;Moist Heat or Steam Sterilization;High-level Disinfectant

Contacts#

Phone, Email table
PhoneEmail
+018002728465xxx@xxx.xxx

Regulatory Flags#

DUNS number
713565195
Device count
1
DM exempt
false
Premarket exempt
true
HCT/P
false
Kit
false
Combination product
false
Lot or batch
true
Serial number
false
Manufacturing date on label
true
Expiration date on label
false
Donation ID number
false
Contains natural rubber latex
false
No natural rubber latex
false
Sterilization required before use
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
04573596201367OASISMR-NVC-120OASIS RAPID NV Coil MR-NVC-1202026-05-29
04573596201398OASISMR-QFC-120OASIS QD Flexible Body Coil(L) MR-QFC-1202026-05-29
04573596201404OASISMR-QFC-120XLOASIS QD Flexible Body Coil(XL) MR-QFC-120XL2026-05-29
04573596201411OASISMR-RFC-120OASIS RAPID Foot Coil MR-RFC-1202026-05-29
04573596201435OASISMR-CTL-120OASIS CTL Coil MR-CTL-1202026-05-29
04573596202159OASISMR-IBC-120OASIS RAPID Breast Coil MR-IBC-1202026-05-29
04547410480269FUJIFILMVS-10002026-05-22
04547410529128FUJIFILMEG-S100XT2026-05-22
04573596200865APERTO LucentMR-JCR-82Joint coil (M) MR-JCR-82 for APERTO Lucent/APEROT 2026-05-22
04573596200889APERTO LucentMR-JC-81Joint coil (S) MRJC-81 for APERTO Lucent/APERTO Et2026-05-22
04573596200896APERTO LucentMR-JCR-83Joint coil (L) MR-JCR-83 for APERTO Lucent/APEROT 2026-05-22
04573596200902APERTO LucentMR-CSC-81C-Spine coil MR-SCS-81 for APERTO Lucent/APERTO Et2026-05-22
04573596200940APERTO LucentMR-QWC-81Wrist coil MR-QWC-81 for APERTO Lucent/Aperto Eter2026-05-22
04573596200964APERTO LucentMR-MSC-81Shoulder coil MR-MSC-81 for APERTO Lucent/APERTO E2026-05-22
04573596200971APERTO LucentMR-QRC-81Head coil (L) MR-QRC-81 for APERTO Lucent/APERTO E2026-05-22
04573596201480APERTO LucentMR-QHC-81RQD Head coil R MR-QHC-81R for APERTO Lucent2026-05-22
04573596201497APERTO LucentMR-QKC-83RQD Knee coil R MR-QKC-83R for APERTO Lucent2026-05-22
04573596201503APERTO LucentMR-IBC-83Open body coil MR-IBC-83 for APERTO Lucent/APERTO 2026-05-22
04573596202210APERTO LucentMR-QFC-82NFlexible Body coil N(M) MR-QFC-82N for APERTO Luce2026-05-22
04573596202227APERTO LucentMR-QFC-83NFlexible Body coil N(L) MR-QFC-83N for APERTO Luce2026-05-22

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00850050934233EndoSound® EVS ProbeEndosound, Inc.ITX2026-06-01
04987670105937DIAGNOSTIC ULTRASOUND SYSTEMCANON INC.ITX2026-06-01
04987670106194DIAGNOSTIC ULTRASOUND SYSTEMCANON INC.ITX2026-06-01
08800013510112L8-17HAlpinion Medical Systems Co., Ltd.ITX2026-05-29
00198953121382VolusonGE Ultrasound Korea Ltd.ITX2026-05-28
08800290027266PA2-9SSAMSUNG MEDISON CO., LTD.ITX2026-04-03
08800290027419LA2-9SDSAMSUNG MEDISON CO., LTD.ITX2026-04-03
08800290028638CA2-8ADSAMSUNG MEDISON CO., LTD.ITX2026-04-03
08800290029390EV2-10ASAMSUNG MEDISON CO., LTD.ITX2026-04-03
08800290029420CV1-8AESAMSUNG MEDISON CO., LTD.ITX2026-04-03
08800290027471EV2-12SAMSUNG MEDISON CO., LTD.ITX2026-01-28
08800289975974R30 Diagnostic Ultrasound SystemSAMSUNG MEDISON CO., LTD.ITX2026-01-20
08800289976025R20 Diagnostic Ultrasound SystemSAMSUNG MEDISON CO., LTD.ITX2026-01-20
08800289979224EA2-11ARnSAMSUNG MEDISON CO., LTD.ITX2026-01-20
08800289979262CA1-7SnSAMSUNG MEDISON CO., LTD.ITX2026-01-20
08800290027297PA2-9SSAMSUNG MEDISON CO., LTD.ITX2026-01-20
08800290027334LA2-9SnSAMSUNG MEDISON CO., LTD.ITX2026-01-20
08800290027365CA3-10AnSAMSUNG MEDISON CO., LTD.ITX2026-01-20
08056304455826MyLabC25ESAOTE SPAITX2025-12-10
08056304455833MyLabC30ESAOTE SPAITX2025-12-10
08800289979132cV4 Diagnostic Ultrasound SystemSAMSUNG MEDISON CO., LTD.ITX2025-09-03
08800289981883cV5 Diagnostic Ultrasound SystemSAMSUNG MEDISON CO., LTD.ITX2025-09-03
08056304455017MyLabA50ESAOTE SPAITX2025-07-07
08056304455215MyLabE85ESAOTE SPAITX2025-07-07
08056304455307MyLabA70ESAOTE SPAITX2025-07-07
08056304455437MyLabA50ESAOTE SPAITX2025-07-07
08056304455451MyLabA70ESAOTE SPAITX2025-07-07
08056304455635MyLabE80ESAOTE SPAITX2025-07-07
08056304455642MyLabE85ESAOTE SPAITX2025-07-07
08800289970351cV8 Diagnostic Ultrasound SystemSAMSUNG MEDISON CO., LTD.ITX2025-02-27