NA

Primary DI
30653405003278
Brand
NA
Company
Conmed Corporation
Model
138019
Catalog number
138019
Device description
1/8" BALL ELECTRODE
Published
2016-09-24
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true
OTC
false
Sterile
false
Single use
false

Contact Domains#

Product Codes#

Code, Name table
CodeName
GEIELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
GEIElectrosurgical, Cutting & Coagulation & AccessoriesGeneral, Plastic Surgery2

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
30653405003278Direct MarkingGS10
20653405003271PackageGS15In Commercial Distribution
10653405003274PrimaryGS10
00653405003277Unit of UseGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, UPC-A table
Source identifierGTIN-14 normalizedUPC-AEAN-13
3065340500327830653405003278
2065340500327120653405003271
1065340500327410653405003274
00653405003277006534050032776534050032770653405003277

GMDN Terms#

Term, Definition table
TermDefinition
Electrosurgical handpiece/electrode holder, single-useA device intended to be used to house or fix an active electrosurgical handpiece/pen with its electrode when not being used by the surgeon during the surgical procedure. This is to secure the conducting unit, especially the electrode, within the sterile operating zone and protect it against potential adverse events. The holder will typically be fastened to an object within the sterile field (e.g., a drape, anaesthesia dividing arm, operating table). This is a single-use device.

Device Sizes#

Type, Value, Unit table
TypeValueUnit
Length1.75Inch
Length4.5Centimeter
Outer Diameter0.125Inch
Outer Diameter3.2Millimeter

Sterilization Methods#

Method table
Method
Moist Heat or Steam Sterilization

Contacts#

Phone, Email table
PhoneEmail
+1(800)237-0169CUSTOMER_SERVICE@CONMED.COM

Regulatory Flags#

DUNS number
071595540
Device count
5
DM exempt
false
Premarket exempt
false
HCT/P
false
Kit
false
Combination product
false
Lot or batch
true
Serial number
false
Manufacturing date on label
true
Expiration date on label
false
Donation ID number
false
Contains natural rubber latex
false
No natural rubber latex
false
Sterilization required before use
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
10845854051399AirSealiAS8-dViAS8-dV2021-08-22
10845854084137AirSeal®iAS8-dVLiAS8-dVL2023-01-06
10845854013137QUICKLATCHQL4300QL43002020-12-10
10845854031841CONMEDT2531T25312020-12-10
10845854036204POWERPROPRO6185PRO61852023-09-01
20845854061807SnapEvacSNAPEVAC20SNAPEVAC202020-06-06
30653405011907EXCEL60-6050-00160-6050-0012016-09-24
30653405988346Argo KnotlessK55RTAPK55RTAP2023-01-13
30653405988360Argo KnotlessK475RTAPK475RTAP2023-01-13
10845854032619CROSSFTTFT-45MTFT-45M2021-01-19
10845854032633CROSSFTTFT-55MTFT-55M2021-01-19
10845854032657CROSSFTTFT-65MTFT-65M2021-01-19
10653405004646ELECTROLASE HYFRECATOR7-100-8BX7-100-8BX2016-09-24
10653405013785THERMOGARD7-3847-3842016-09-24
10845854650134THERMOGARD7-3827-3822022-09-21
20653405051906Precisor0008520008522016-09-24
20653405051920Precisor0008540008542016-09-24
30653405046800BiCap SuperconductorBP-10300ABP-10300A2016-09-24
30653405046992BiCap SuperconductorBP-7300ABP-7300A2016-09-24
30653405047005BiCap SuperconductorBP-5200ABP-5200A2016-09-24

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
07613327693287MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693294MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693362MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693379MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693386MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693393MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693409MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693416MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693423MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693430MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693447MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693454MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693461MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693478MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693485MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693492MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693508MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693515MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693522MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693539MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693546MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693553MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693560MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693577MalisSTRYKER CORPORATIONGEI2026-02-25
07613327556469NeptuneSTRYKER CORPORATIONGEI2025-01-30
07613327548204Neptune SafeAirSTRYKER CORPORATIONGEI2025-01-06
07613327556650NeptuneSTRYKER CORPORATIONGEI2024-12-13
07613327548129NeptuneSTRYKER CORPORATIONGEI2024-12-10
07613327548143NeptuneSTRYKER CORPORATIONGEI2024-12-10
07613327548167NeptuneSTRYKER CORPORATIONGEI2024-12-10