Looking Glass

Primary DI
30845854050693
Brand
Looking Glass
Company
Conmed Corporation
Model
AV4132
Catalog number
AV4132
Device description
Looking Glass 4K Integrated Visualization System
Published
2020-07-20
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
GCJLaparoscope, general & plastic surgery

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
GCJLaparoscope, General & Plastic SurgeryGastroenterology, Urology2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K201593000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K201593000Looking Glass 4K Integrated Visualization SystemConmed Corporation2020-07-08GCJ

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
10845854050699Direct MarkingGS10
30845854050693PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized table
Source identifierGTIN-14 normalized
1084585405069910845854050699
3084585405069330845854050693

GMDN Terms#

Term, Definition table
TermDefinition
Endoscopic video image processing unitAn electrically-powered device designed to receive and process the electronic signals sent from a video endoscope or endoscopic video camera; it does not include the endoscope nor light source and is not designed to control the endoscope. It may have additional features which compensate for/enhance the colour and light qualities provided. The resulting picture images are sent to and shown on a visual display unit (VDU), typically to assist the endoscope operator with an ongoing intervention and often to allow the patient visualization of the process; the images can be recorded on a video recorder or stored on computerized media.

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Storage Environment Atmospheric Pressure70 KiloPascal106 KiloPascal
Storage Environment Humidity10 Percent (%) Relative Humidity90 Percent (%) Relative Humidity
Storage Environment Temperature-20 Degrees Celsius60 Degrees Celsius
Storage Environment Temperature-4 Degrees Fahrenheit140 Degrees Fahrenheit

Contacts#

Phone, Email table
PhoneEmail
+1(866)426-6633CustomerExperience@conmed.com

Regulatory Flags#

DUNS number
071595540
Device count
1
Serial number
true
Manufacturing date on label
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
20845854042004Y-KNOTYH01YH012015-10-24
20845854042028Y-KNOTYH02YH022015-10-24
10845854087534Infinity™QTSLQTSL2026-06-10
10845854087541Infinity™QTSRQTSR2026-06-10
10845854087558Infinity™RDBHRDBH2026-06-10
20653405990328Infinity™QTCRQTCR2026-06-10
20653405990366Infinity™ADB-0808ADB-08082026-06-10
20653405990373Infinity™ADB-0609ADB-06092026-06-10
20653405990380Infinity™ADB-0809ADB-08092026-06-10
20653405990397Infinity™ADB-0610ADB-06102026-06-10
20653405990403Infinity™ADB-0810ADB-08102026-06-10
20653405990410Infinity™ADB-0611ADB-06112026-06-10
20653405990427Infinity™DB-0808DB-08082026-06-10
20653405990434Infinity™DB-0609DB-06092026-06-10
20653405990441Infinity™DB-0809DB-08092026-06-10
20653405990458Infinity™DB-0610DB-06102026-06-10
20653405990465Infinity™DB-0810DB-08102026-06-10
20653405990472Infinity™DB-0611DB-06112026-06-10
10653405002765ABC® Bend-A-Beam®1340091340092016-09-24
10845854015506CONMEDC2630C26302015-12-10

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00198506092176ELMED INCORPORATEDELMED INCORPORATEDGCJ2026-07-17
00888867561793Arthrex®ARTHREX, INC.GCJ2026-07-17
B382SD90781001000Surgical DirectSurgical Direct, Inc.GCJ2026-07-17
B382SD9918100Surgical DirectSurgical Direct, Inc.GCJ2026-07-17
B382SD1184590Surgical DirectSurgical Direct, Inc.GCJ2026-07-14
B382SD12711090Surgical DirectSurgical Direct, Inc.GCJ2026-07-14
B382SD1271390Surgical DirectSurgical Direct, Inc.GCJ2026-07-14
B382SD1271590Surgical DirectSurgical Direct, Inc.GCJ2026-07-14
B382SD13018770Surgical DirectSurgical Direct, Inc.GCJ2026-07-14
B382SD13168350Surgical DirectSurgical Direct, Inc.GCJ2026-07-14
B382SD23373490Surgical DirectSurgical Direct, Inc.GCJ2026-07-14
B382SD770561050Surgical DirectSurgical Direct, Inc.GCJ2026-07-14
B382SD775011530Surgical DirectSurgical Direct, Inc.GCJ2026-07-14
B382SD775021630Surgical DirectSurgical Direct, Inc.GCJ2026-07-14
B382SD77505650Surgical DirectSurgical Direct, Inc.GCJ2026-07-14
B382SD7751586C0Surgical DirectSurgical Direct, Inc.GCJ2026-07-14
B382SD7751587C0Surgical DirectSurgical Direct, Inc.GCJ2026-07-14
00850045863012ArthroFree® 2 ReceiverLazurite Holdings LLCGCJ2026-07-10
00850045863029ArthroFree® 2 Wireless Camera HeadLazurite Holdings LLCGCJ2026-07-10
00850045863036ArthroFree® 2 Operating Room KitLazurite Holdings LLCGCJ2026-07-10
00850045863043ArthroFree® 2 Single Camera Head SetLazurite Holdings LLCGCJ2026-07-10
B382SD883110450Surgical DirectSurgical Direct, Inc.GCJ2026-07-10
B382SD88324450Surgical DirectSurgical Direct, Inc.GCJ2026-07-10
00190776421731MillenniumAvalign Technologies, Inc.GCJ2026-06-24
00190776421663MillenniumAvalign Technologies, Inc.GCJ2026-06-23
00190776421687MillenniumAvalign Technologies, Inc.GCJ2026-06-23
00198506091506ELMED INCORPORATEDELMED INCORPORATEDGCJ2026-06-10
00198506044366ELMEDELMED INCORPORATEDGCJ2026-06-09
00812231033906PixaSANTA BARBARA IMAGING SYSTEMS, INC.GCJ2026-06-08
00812231033913PixaSANTA BARBARA IMAGING SYSTEMS, INC.GCJ2026-06-08