Verifit Skull Simulator

Primary DI
B161VA3000
Brand
Verifit Skull Simulator
Company
Etymonic Design Incorporated
Model
VA-300
Device description
An optional accessory to the Audioscan Verifit VF-2 or Verifit VF-1 hearing aid analyzer or hearing instrument test (HIT) system. The VA-300 Verifit Skull Simulator is a measurement coupler operating in place of a standard acoustic coupler to facilitate measurement of the vibrational output produced by a bone conduction hearing aid. The device is intended as a direct substitute for the acoustic measurement coupler and uses the identical micro-power electrical interface.
Published
2019-05-02
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information

Product Codes#

Code, Name table
CodeName
ETWCalibrator, Hearing Aid / Earphone And Analysis Systems

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
ETWCalibrator, Hearing Aid / Earphone And Analysis SystemsEar, Nose, Throat2

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
B161VA3003PackageHIBCC1In Commercial Distribution
B161VA3000PrimaryHIBCC0

GMDN Terms#

Term, Definition table
TermDefinition
Artificial mastoidAn electrically-powered benchtop device designed to simulate the mechanical impedance of the human mastoid bone to calibrate/test bone conduction hearing aids or for determination of output force of a bone vibrator [specified in standard (IEC 60318-6)]. Also known as a mechanical coupler, it is equipped with a mechano-electric transducer to enable an alternating force level to be determined.

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Atmospheric Pressure81 KiloPascal106 KiloPascal
Handling Environment Humidity20 Percent (%) Relative Humidity50 Percent (%) Relative Humidity
Handling Environment Temperature15 Degrees Celsius30 Degrees Celsius
Storage Environment Humidity5 Percent (%) Relative Humidity95 Percent (%) Relative Humidity
Storage Environment Temperature-20 Degrees Celsius60 Degrees Celsius

Regulatory Flags#

DUNS number
244780581
Device count
1
Premarket exempt
true
Serial number
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
B161AXIOM0AudioscanAxiom2016-09-23
B161RM500SL0AudioscanRM500SL2016-09-23
B161RE3670Audioscan Probe TubeRE367RE367-402020-01-15
B161VERIFITVF20AudioscanVerifit VF-22016-09-23
B161VA3003Verifit Skull SimulatorVA-3002019-05-02
B161AXIOM3AudioscanAxiom2016-09-23
B161RM500SL3AudioscanRM500SL2016-09-23

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
05711781004297Measure by Otometrics - HITAuditdata A/SETW2025-11-14
05711781004372Measure by Otometrics - HITAuditdata A/SETW2025-11-14
05711781004006Unity 3Auditdata A/SETW2024-10-21
05711117244335Sanibel Supply A/SInteracoustics A/SETW2024-10-07
05711117228458Sanibel Supply A/SInteracoustics A/SETW2024-10-07
00810044583182MedRxMEDRX, INC.ETW2024-05-07
EADF03410600217207189audifonaudifon GmbH & Co. KGETW2023-03-31
05711117121742Sanibel Supply A/SInteracoustics A/SETW2022-12-29
05711117094206Sanibel Supply A/SInteracoustics A/SETW2022-12-29
05711117226478Sanibel Supply A/SInteracoustics A/SETW2022-12-29
05711117227550Sanibel Supply A/SInteracoustics A/SETW2022-11-29
05711117227574Sanibel Supply A/SInteracoustics A/SETW2022-11-29
05711117227581Sanibel Supply A/SInteracoustics A/SETW2022-11-29
05711117228557Sanibel Supply A/SInteracoustics A/SETW2022-11-29
05711117228564Sanibel Supply A/SInteracoustics A/SETW2022-11-29
05711117228571Sanibel Supply A/SInteracoustics A/SETW2022-11-29
EADF034106002172068681audifonaudifon GmbH & Co. KGETW2022-10-21
05713315009037NatusNatus Medical Denmark ApSETW2021-04-12
05713315009044NatusNatus Medical Denmark ApSETW2021-04-12
05713315009051NatusNatus Medical Denmark ApSETW2021-04-12
05713315008689NatusNatus Medical Denmark ApSETW2021-01-04
B161RE3670Audioscan Probe TubeEtymonic Design IncorporatedETW2020-01-15
05711117198218InteracousticsInteracoustics A/SETW2019-11-26
B161VA3003Verifit Skull SimulatorEtymonic Design IncorporatedETW2019-05-02
05713315005848GN Otometrics A/SNatus Medical Denmark ApSETW2019-04-24
05713315008184GN Otometrics A/SNatus Medical Denmark ApSETW2019-03-18
05713315005701GN Otometrics A/SNatus Medical Denmark ApSETW2018-11-06
05713315003301GN Otometrics A/SNatus Medical Denmark ApSETW2018-07-31
08054187380730DRUMINVENTIS SRLETW2017-08-24
08054187380617TRUMPETINVENTIS SRLETW2016-11-23