Canaveral®

Primary DI
B1830112950250
Brand
Canaveral®
Company
FLOSPINE LLC
Model
Canaveral®
Catalog number
01-1295-025
Device description
Reduction Polyaxial Screw Assembly, 9.5mm x 25mm
Published
2016-06-30
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true
Single use
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
KWPAppliance, Fixation, Spinal Interlaminal
MNHOrthosis, Spondylolisthesis Spinal Fixation
MNIOrthosis, Spinal Pedicle Fixation
NKBOrthosis, Spinal Pedicle Fixation, For Degenerative Disc Disease
OSHPedicle Screw Spinal System, Adolescent Idiopathic Scoliosis

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
KWPAppliance, Fixation, Spinal InterlaminalOrthopedic2
MNHOrthosis, Spondylolisthesis Spinal FixationOrthopedic2
MNIOrthosis, Spinal Pedicle FixationOrthopedic2
NKBThoracolumbosacral Pedicle Screw SystemOrthopedic2
OSHPedicle Screw Spinal System, Adolescent Idiopathic ScoliosisOrthopedic2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K141850000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K141850000FLOSPINE PEDICLE SCREW SYSTEMFlospine2014-10-27NKB

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
B1830112950250PrimaryHIBCC0

GMDN Terms#

Term, Definition table
TermDefinition
Spinal bone screw, non-bioabsorbableA small, threaded, implantable rod with a screw head and drive intended for internal spinal fixation by being screwed into the spine to hold a correction/stabilization device (e.g., rod, plate, tether) to bone; it is made of a material that is not chemically degraded or absorbed via natural body processes (e.g., surgical steel, titanium alloy, carbon fibre). It is available in various types (e.g., pedicle or transfacet, with a slotted, cross, star, or polygonal drive), and is typically used to provide immobilization and stabilization of spinal segments in the treatment of spinal instabilities or deformities. A screw head adaptor intended to stabilize a rod may be included with the screw.

Device Sizes#

Type, Value, Unit table
TypeValueUnit
Length25Millimeter
Outer Diameter9.5Millimeter

Sterilization Methods#

Method table
Method
Moist Heat or Steam Sterilization

Contacts#

Phone, Email table
PhoneEmail
(561) 705-3080info@flospine.com

Regulatory Flags#

DUNS number
042993143
Device count
1
Lot or batch
true
Sterilization required before use
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
B1830802450120Panama™Panama™08-0245-0122021-09-01
B1830802450140Panama™Panama™08-0245-0142021-09-01
B1830802450160Panama™Panama™08-0245-0162021-09-01
B1830802450180Panama™Panama™08-0245-0182021-09-01
B1830802450200Panama™Panama™08-0245-0202021-09-01
B1830803400120Panama™Panama™08-0340-0122021-09-01
B1830803400140Panama™Panama™08-0340-0142021-09-01
B1830803400160Panama™Panama™08-0340-0162021-09-01
B1830803400180Panama™Panama™08-0340-0182021-09-01
B1830803400200Panama™Panama™08-0340-0202021-09-01
B1830803450120Panama™Panama™08-0345-0122021-09-01
B1830803450140Panama™Panama™08-0345-0142021-09-01
B1830803450160Panama™Panama™08-0345-0162021-09-01
B1830803450180Panama™Panama™08-0345-0182021-09-01
B1830803450200Panama™Panama™08-0345-0202021-09-01
B1830804400120Panama™Panama™08-0440-0122021-09-01
B1830804400140Panama™Panama™08-0440-0142021-09-01
B1830804400160Panama™Panama™08-0440-0162021-09-01
B1830804400180Panama™Panama™08-0440-0182021-09-01
B1830804400200Panama™Panama™08-0440-0202021-09-01

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00197157059521ZAVATION RODZavation LLCNKB2026-06-04
00197157059538ZAVATION RODZavation LLCNKB2026-06-04
00197157059545ZAVATION RODZavation LLCNKB2026-06-04
00197157059552ZAVATION RODZavation LLCNKB2026-06-04
00197157059569ZAVATION RODZavation LLCNKB2026-06-04
00197157059576ZAVATION RODZavation LLCNKB2026-06-04
00197157059583ZAVATION RODZavation LLCNKB2026-06-04
00197157059590ZAVATION RODZavation LLCNKB2026-06-04
00197157059606ZAVATION RODZavation LLCNKB2026-06-04
00197157059613ZAVATION RODZavation LLCNKB2026-06-04
00197157059620ZAVATION RODZavation LLCNKB2026-06-04
00197157059637ZAVATION RODZavation LLCNKB2026-06-04
00197157059644ZAVATION RODZavation LLCNKB2026-06-04
00197157059651ZAVATION RODZavation LLCNKB2026-06-04
00197157059668ZAVATION RODZavation LLCNKB2026-06-04
00197157081515ZAVATION SCREWZavation LLCKWP2026-06-04
00197157081522ZAVATION SCREWZavation LLCKWP2026-06-04
00197157081539ZAVATION SCREWZavation LLCKWP2026-06-04
00197157081546ZAVATION SCREWZavation LLCKWP2026-06-04
00197157081553ZAVATION SCREWZavation LLCKWP2026-06-04
00197157081560ZAVATION SCREWZavation LLCKWP2026-06-04
00197157081577ZAVATION SCREWZavation LLCKWP2026-06-04
00197157081584ZAVATION SCREWZavation LLCKWP2026-06-04
00197157081591ZAVATION SCREWZavation LLCKWP2026-06-04
00197157081607ZAVATION SCREWZavation LLCKWP2026-06-04
00197157081614ZAVATION SCREWZavation LLCKWP2026-06-04
00197157081621ZAVATION SCREWZavation LLCKWP2026-06-04
00197157081638ZAVATION SCREWZavation LLCKWP2026-06-04
00197157081645ZAVATION SCREWZavation LLCKWP2026-06-04
00197157081652ZAVATION SCREWZavation LLCKWP2026-06-04