IEC-Innoview GmbH

Primary DI
B192300048000
Brand
IEC-Innoview GmbH
Company
INNOVATIVE ENDOSCOPY COMPONENTS, L.L.C.
Model
30-0048-00
Catalog number
30-0048-00
Device description
10 mm, 70 deg. Laryngoscope, l=190 mm, autoclavable
Published
2023-06-08
Public version status
New
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information

Product Codes#

Code, Name table
CodeName
LRCInstrument, Ent Manual Surgical

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
LRCInstrument, Ent Manual SurgicalEar, Nose, Throat1

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
B192300048000PrimaryHIBCC0

GMDN Terms#

Term, Definition table
TermDefinition
Rigid intubation laryngoscope, reusableA hand-held device intended to be used by anaesthesia/emergency service personnel to manipulate the tongue, preventing it from obstructing the oropharynx and enabling a clear view of the trachea for the insertion of an endotracheal (ET) tube prior to the delivery of inhalation anaesthesia and/or ventilation. It has a handle containing batteries to power its light (a small built-in light bulb or fibreoptic light) for airway illumination, and a curved or straight blade of various designs and lengths that can be hinged/interchanged or integral. Some types can be magnetic resonance imaging (MRI) compatible. This is a reusable device.

Device Sizes#

Type, Value, Unit table
TypeValueUnit
Angle70degree
Length190Millimeter
Outer Diameter10Millimeter

Sterilization Methods#

Method table
Method
Moist Heat or Steam Sterilization

Regulatory Flags#

DUNS number
010741028
Device count
1
DM exempt
true
Premarket exempt
true
Serial number
true
Sterilization required before use
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
B192300003000IEC-Innoview GmbH30-0003-0030-0003-002016-05-31
B192300004000IEC-Innoview GmbH30-0004-0030-0004-002016-05-23
B192300006000IEC-Innoview GmbH30-0006-0030-0006-002016-05-23
B192300008000IEC-Innoview GmbH30-0008-0030-0008-002016-05-23
B192300010000IEC-Innoview GmbH30-0010-0030-0010-002016-05-23
B192300011000IEC-Innoview GmbH30-0011-0030-0011-002016-05-24
B192300012000IEC-Innoview GmbH30-0012-0030-0012-002016-05-24
B192300054000IEC-Innoview GmbH30-0054-0030-0054-002016-06-02
B192300055000IEC-Innoview GmbH30-0055-0030-0055-002016-05-24
B192300057000IEC-Innoview GmbH30-0057-0030-0057-002016-05-24
B192300068000IEC-Innoview GmbH30-0068-0030-0068-002016-07-12
B192300311000IEC-Innoview GmbH30-0311-0030-0311-002016-05-24
B192300346000IEC-Innoview GmbH30-0346-0030-0346-002016-05-24
B192300348000IEC-Innoview GmbH30-0348-0030-0348-002016-05-24
B192300421000IEC-Innoview GmbH30-0421-0030-0421-002016-05-24
B192300514000IEC-Innoview GmbH30-0514-0030-0514-002016-05-26
B192300515000IEC-Innoview GmbH30-0515-0030-0515-002016-05-26
B192300646000IEC-Innoview GmbH30-0646-0030-0646-002016-07-12
B1921091313550Eberle10-91313-5510-91313-552023-06-08
B192300049000IEC-Innoview GmbH30-0049-0030-0049-002023-06-08

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00198506091315ELMED INCORPORATEDELMED INCORPORATEDLRC2026-06-09
00198506091322ELMED INCORPORATEDELMED INCORPORATEDLRC2026-06-09
00198506091346ELMED INCORPORATEDELMED INCORPORATEDLRC2026-06-09
00198506091155ELMED INCORPORATEDELMED INCORPORATEDLRC2026-06-03
00198506091162ELMED INCORPORATEDELMED INCORPORATEDLRC2026-06-03
00198506091186ELMED INCORPORATEDELMED INCORPORATEDLRC2026-06-03
00198506091193ELMED INCORPORATEDELMED INCORPORATEDLRC2026-06-03
00198506091223ELMED INCORPORATEDELMED INCORPORATEDLRC2026-06-03
14250368820892Soft CliP HookHeinz Kurz GmbHLRC2026-05-21
14250368861437Trocar HandleHeinz Kurz GmbHLRC2026-05-21
14250368862007Cartilage PunchHeinz Kurz GmbHLRC2026-05-21
00198506090790ELMED INCORPORATEDELMED INCORPORATEDLRC2026-05-15
00198506090752ELMED INCORPORATEDELMED INCORPORATEDLRC2026-05-13
00198506090769ELMED INCORPORATEDELMED INCORPORATEDLRC2026-05-13
00190776421366MillenniumAvalign Technologies, Inc.LRC2026-05-05
00198506090479ELMED INCORPORATEDELMED INCORPORATEDLRC2026-05-05
00190776420758MillenniumAvalign Technologies, Inc.LRC2026-04-30
00190776420871MillenniumAvalign Technologies, Inc.LRC2026-04-30
00198506090387ELMED INCORPORATEDELMED INCORPORATEDLRC2026-04-30
00198506090394ELMED INCORPORATEDELMED INCORPORATEDLRC2026-04-30
00757770535620Bausch + LombBausch & Lomb IncorporatedLRC2026-04-30
00198506090318ELMED INCORPORATEDELMED INCORPORATEDLRC2026-04-28
00198506090257ELMED INCORPORATEDELMED INCORPORATEDLRC2026-04-21
00198506090288ELMED INCORPORATEDELMED INCORPORATEDLRC2026-04-21
00190776419950MillenniumAvalign Technologies, Inc.LRC2026-04-15
00190776419578MillenniumAvalign Technologies, Inc.LRC2026-04-14
00190776419585MillenniumAvalign Technologies, Inc.LRC2026-04-14
00190776418977MillenniumAvalign Technologies, Inc.LRC2026-04-13
00198506089954ELMED INCORPORATEDELMED INCORPORATEDLRC2026-04-03
00198506089497ELMED INCORPORATEDELMED INCORPORATEDLRC2026-04-02