Sonoclot® NonActivated Kit 800-0425

GUDID B55880004250

The Non-Activated Clotting Test Kit contains the necessary components for an in vitro diagnostic test for use with the Sonoclot® Coagulation & Platelet Function Analyzer System. It may be used with native whole blood, citrated whole blood, and plasma. The Non-Activated Kit may either be used as a non-activated clotting test or as a general use test with user provided activators. It is intended for customer designed hemostasis monitoring on the Sonoclot Analyzer. The Non-Activated cuvette allows for coagulation monitoring using tissue activation, thrombin activation, and other custom activators. Some of the applications for the Non-Activated test with the addition of customer determined reagents are monitoring of fibrin formation, fibrinolysis, hyperfibrinolysis and clot retraction. When used with the Sonoclot Analyzer System, the Non-Activated test provides quantitative Onset/ACT and Clot Rate results as well as qualitative and quantitative information on the Sonoclot Signature including: fibrin formation, platelet function, and hyperfibrinolysis. Each kit contains 100 lidded plastic cuvettes, 100 probes, and instructions for use. The cuvettes contain a magnetic stir bar.

SIENCO, INC.

Multiple coagulation factor IVD, kit, clotting
Primary Device IDB55880004250
NIH Device Record Key7feb0ebc-3f94-4de7-9261-41e93671ce08
Commercial Distribution StatusIn Commercial Distribution
Brand NameSonoclot® NonActivated Kit
Version Model Number800-0425
Catalog Number800-0425
Company DUNS064039514
Company NameSIENCO, INC.
Device Count100
DM Exemptfalse
Pre-market Exemptfalse
MRI Safety StatusLabeling does not contain MRI Safety Information
Human Cell/Tissue Productfalse
Device Kittrue
Device Combination Productfalse
Single Usetrue
Lot Batchtrue
Serial Numberfalse
Manufacturing Datefalse
Expiration Datefalse
Donation Id Numberfalse
Contains Natural Rubber Latexfalse
Labeled No Natural Rubber Latexfalse
RX Perscriptionfalse
OTC Over-The-Counterfalse

Customer Support Contacts

Phone303-420-1148
Emailinfo@sienco.com
Phone303-420-1148
Emailinfo@sienco.com
Phone303-420-1148
Emailinfo@sienco.com
Phone303-420-1148
Emailinfo@sienco.com
Phone303-420-1148
Emailinfo@sienco.com
Phone303-420-1148
Emailinfo@sienco.com
Phone303-420-1148
Emailinfo@sienco.com

Operating and Storage Conditions

Storage Environment TemperatureBetween 0 Degrees Celsius and 25 Degrees Celsius
Storage Environment TemperatureBetween 0 Degrees Celsius and 25 Degrees Celsius
Storage Environment TemperatureBetween 0 Degrees Celsius and 25 Degrees Celsius
Storage Environment TemperatureBetween 0 Degrees Celsius and 25 Degrees Celsius
Storage Environment TemperatureBetween 0 Degrees Celsius and 25 Degrees Celsius
Storage Environment TemperatureBetween 0 Degrees Celsius and 25 Degrees Celsius
Storage Environment TemperatureBetween 0 Degrees Celsius and 25 Degrees Celsius

Device Identifiers

Device Issuing AgencyDevice ID
HIBCCB55880004250 [Unit of Use]
HIBCCB55880004251 [Primary]

FDA Pre-market Approvals/Notifications & deNovo

FDA Product Code

JPASystem, Multipurpose For In Vitro Coagulation Studies

Sterilization

Steralize Prior To Usefalse
Device Is Sterilefalse

Device Entry Metadata

Public Version StatusNew
Device Record StatusPublished
Public Version Number1
Public Version Date2021-07-27
Device Publish Date2021-07-19

On-Brand Devices [Sonoclot® NonActivated Kit]

B55880004260The Non-Activated Clotting Test Kit contains the necessary components for an in vitro diagnostic
B55880004250The Non-Activated Clotting Test Kit contains the necessary components for an in vitro diagnostic

Trademark Results [Sonoclot]

Mark Image

Registration | Serial
Company
Trademark
Application Date
SONOCLOT
SONOCLOT
85825814 4388109 Live/Registered
Sienco, Incorporated
2013-01-17
SONOCLOT
SONOCLOT
73040018 1039577 Dead/Expired
SIMONS, SANFORD L.
1974-12-20

© 2024 FDA.report
This site is not affiliated with or endorsed by the FDA.