CINA-iPE

GUDID B826CINAIPE100

CINA-iPE is a radiological computer-aided triage and notification software indicated for use in patients undergoing contrast-enhanced CT scans (not dedicated CTPA protocol) for other clinical indications than pulmonary embolism suspicion, including at least a part of the lung. The device is intended to assist hospital networks and trained radiologists in workflow triage by flagging and communicating suspected positive findings for incidental Pulmonary Embolism (iPE). The device is indicated for adults and transitional adolescents (18 to 21 years old but treated as adults). CINA-iPE uses an artificial intelligence algorithm to analyze images and highlight cases with detected incidental PE on a standalone application in parallel to the ongoing standard of care image interpretation. The user is presented with notifications for cases with suspected incidental PE findings. The device is not designed to detect PE in subsegmental arteries. Notifications include compressed preview images that are meant for informational purposes only and are not intended for diagnostic use beyond notification. The device does not alter the original medical image, and it is not intended to be used as a diagnostic device. The results of CINA-iPE are intended to be used in conjunction with other patient information and based on professional judgment to assist with the triage/prioritization of medical images. Notified clinicians are ultimately responsible for reviewing full images per the standard of care.

AVICENNA.AI

Radiology DICOM image processing application software
Primary Device IDB826CINAIPE100
NIH Device Record Keyc7290824-1311-43fe-a191-265dd9ec0af4
Commercial Distribution StatusIn Commercial Distribution
Brand NameCINA-iPE
Version Model Number1.0
Company DUNS271198112
Company NameAVICENNA.AI
Device Count1
DM Exemptfalse
Pre-market Exemptfalse
MRI Safety StatusLabeling does not contain MRI Safety Information
Human Cell/Tissue Productfalse
Device Kitfalse
Device Combination Productfalse
Single Usefalse
Lot Batchtrue
Serial Numbertrue
Manufacturing Datefalse
Expiration Datefalse
Donation Id Numberfalse
Contains Natural Rubber Latexfalse
Labeled No Natural Rubber Latexfalse
RX Perscriptiontrue
OTC Over-The-Counterfalse

Device Identifiers

Device Issuing AgencyDevice ID
HIBCCB826CINAIPE100 [Primary]

FDA Pre-market Approvals/Notifications & deNovo

FDA Product Code

QASRadiological Computer-Assisted Triage And Notification Software

Sterilization

Steralize Prior To Usefalse
Device Is Sterilefalse

Device Entry Metadata

Public Version StatusNew
Device Record StatusPublished
Public Version Number1
Public Version Date2024-04-08
Device Publish Date2024-03-29

Devices Manufactured by AVICENNA.AI

B826CINAVCF100 - CINA-VCF2024-06-28 CINA-VCF is a radiological computer aided triage and notification software indicated for use in patients aged 50 years and over
B826CINAASPECTS150 - CINA-ASPECTS2024-04-08 CINA-ASPECTS is a computer-aided diagnosis (CADx) software device used to assist the clinician in the assessment and characteriz
B826CINAIPE100 - CINA-iPE2024-04-08CINA-iPE is a radiological computer-aided triage and notification software indicated for use in patients undergoing contrast-enhanced CT scans (not dedicated CTPA protocol) for other clinical indications than pulmonary embolism suspicion, including at least a part of the lung. The device is intended to assist hospital networks and trained radiologists in workflow triage by flagging and communicating suspected positive findings for incidental Pulmonary Embolism (iPE). The device is indicated for adults and transitional adolescents (18 to 21 years old but treated as adults). CINA-iPE uses an artificial intelligence algorithm to analyze images and highlight cases with detected incidental PE on a standalone application in parallel to the ongoing standard of care image interpretation. The user is presented with notifications for cases with suspected incidental PE findings. The device is not designed to detect PE in subsegmental arteries. Notifications include compressed preview images that are meant for informational purposes only and are not intended for diagnostic use beyond notification. The device does not alter the original medical image, and it is not intended to be used as a diagnostic device. The results of CINA-iPE are intended to be used in conjunction with other patient information and based on professional judgment to assist with the triage/prioritization of medical images. Notified clinicians are ultimately responsible for reviewing full images per the standard of care.
B826CINAIPE100 - CINA-iPE2024-04-08 CINA-iPE is a radiological computer-aided triage and notification software indicated for use in patients undergoing contrast-en
B826CINACHEST100 - CINA CHEST2021-06-10 CINA CHEST is a radiological computer aided triage and notification software indicated for use in the analysis of Chest and Thor
B826CINA100 - CINA2020-12-22 CINA is a radiological computer-assisted triage and notification software device. The software system is based on algorithm-prog