Wi-3 HAL-RAR Unit

Primary DI
EAMITRI20100
Brand
Wi-3 HAL-RAR Unit
Company
AMI Agency for Medical Innovations GmbH
Model
TRI2010
Catalog number
TRI2010
Device description
Electronic unit for identifying the localised haemorrhoidal arteries by means of acoustic signals. Part of the Wi-3 HAL-RAR System.The Wi-3 HAL-RAR System (HAL - Hemorrhoidal Artery Ligation, RAR - Recto Anal Repair) is a Bluetooth-enabled, pulsed Doppler, ultrasound system intended to be used for detecting hemorrhoidal arteries, to manually ligate these arteries (HAL), and subsequently carry out a mucopexy of hemorrhoidal tissue prolapse (RAR) if necessary.
Published
2019-01-09
Public version status
Update
Distribution status
Not in Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Product Codes#

Code, Name table
CodeName
FHNLigator, Hemorrhoidal
IYNSystem, Imaging, Pulsed Doppler, Ultrasonic

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
FHNLigator, HemorrhoidalGastroenterology, Urology2
IYNSystem, Imaging, Pulsed Doppler, UltrasonicRadiology2

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
EAMITRI20100PrimaryHIBCC0

GMDN Terms#

Term, Definition table
TermDefinition
Noninvasive vascular ultrasound system, battery-poweredA hand-held, battery-powered device assembly consisting of a graphical display unit and an attached probe or interchangeable probes, designed to noninvasively locate and assess the extent of vascular flow restriction (e.g., clots, stenosis, mechanical damage) by measuring blood flow rate using ultrasound/Doppler/transit time technology. Clinical applications include venous/arterial flow screening (e.g., assessment of air embolism, atherosclerosis, varicose veins, venous thrombosis, and the vascular states of partially severed extremities), ankle pressure index, and/or blood flow wave form recording.

Device Sizes#

Type, Value, Unit table
TypeValueUnit
Height7Centimeter
Outer Diameter23Centimeter

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Humidity30 Percent (%) Relative Humidity75 Percent (%) Relative Humidity
Handling Environment Temperature10 Degrees Celsius35 Degrees Celsius
Handling Environment Temperature70 KiloPascal106 KiloPascal
Storage Environment Atmospheric Pressure50 KiloPascal106 KiloPascal
Storage Environment Humidity10 Percent (%) Relative Humidity75 Percent (%) Relative Humidity
Storage Environment Temperature-20 Degrees Celsius60 Degrees Celsius

Sterilization Methods#

Method table
Method
Moist Heat or Steam Sterilization

Regulatory Flags#

DUNS number
303655286
Device count
1
Premarket exempt
true
Lot or batch
true
Serial number
true
Manufacturing date on label
true
Expiration date on label
true
Sterilization required before use
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
EAMIRAR20810RAR Flexi ProbeRAR2081RAR20812018-11-28
EAMIICT50100i-Cut Power SupplyICT50102025-05-05
EAMIICT50110i-CutICT5011ICT50112025-05-05
EAMIICT50500i-Cut Power Supply Type AICT50502025-05-05
EAMIECI10310A.M.I. EasyClinch Disposable Tips PremiumECI1031ECI10312019-04-05
EAMIECM10110EasyClinch microECM1011ECM10112019-04-05
EAMIEDI10310A.M.I. EasyDissect Disposable Tips PremiumEDI1031EDI10312019-04-05
EAMIEDI10510A.M.I. EasyHookEDI1051EDI10512019-04-05
EAMIEDM10110EasyDissect microEDM1011EDM10112019-04-05
EAMIESI11310A.M.I. EasyShear Disposable Tips PremiumESI1131ESI11312019-04-05
EAMIESI11510A.M.I. EasyShear Mini Disposable Tips PremiumESI1151ESI11512019-04-05
EAMIESI12100Soft InsertsESI1210ESI12102019-04-05
EAMIESM10110EasyShears microESM1011ESM10112019-04-05
EAMIEVI10110ViperEVI1011EVI10112019-04-05
EAMIEAH10100EasyAct HandleEAH1010EAH10102019-04-05
EAMIEAS13100EasyAct 3 SEAS1310EAS13102019-04-05
EAMIEAS13200EasyAct 3 MEAS1320EAS13202019-04-05
EAMIEAS15100EasyAct 5 SEAS1510EAS15102019-04-05
EAMIEAS15200EasyAct 5 MEAS1520EAS15202019-04-05
EAMIEAS15300EasyAct 5 LEAS1530EAS15302019-04-05

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00198953121382VolusonGE Ultrasound Korea Ltd.IYN2026-05-28
08800290066784EVO Q10 Diagnostic Ultrasound SystemSAMSUNG MEDISON CO., LTD.IYN2026-04-03
08800340506147EVO QH10 Diagnostic Ultrasound SystemSAMSUNG MEDISON CO., LTD.IYN2026-04-03
08800340509988EVO XQ10 Diagnostic Ultrasound SystemSAMSUNG MEDISON CO., LTD.IYN2026-04-03
08033638801710Self-Suction-LEMSAPI MED SPAFHN2026-02-06
08800290041934LA2-9SSAMSUNG MEDISON CO., LTD.IYN2025-12-05
08800290042665CA3-10ASAMSUNG MEDISON CO., LTD.IYN2025-12-05
08800290041699L3-22SAMSUNG MEDISON CO., LTD.IYN2025-10-13
08800290042122LA2-16SSAMSUNG MEDISON CO., LTD.IYN2025-10-13
08800290042788LA2-14ASAMSUNG MEDISON CO., LTD.IYN2025-10-13
08800290042849CA1-7SSAMSUNG MEDISON CO., LTD.IYN2025-10-13
08056304455031MyLabOmega eXPESAOTE SPAIYN2023-12-14
08033638801673LEMSAPI MED SPAFHN2023-07-27
08033638802328LEMSAPI MED SPAFHN2023-07-27
08033638803301Self-Suction-LEMSAPI MED SPAFHN2023-07-27
08056304454676MyLabX9ESAOTE SPAIYN2023-06-13
08800013544001X-CUBE 50Alpinion Medical Systems Co., Ltd.IYN2022-11-01
08800013545008X-CUBE 60Alpinion Medical Systems Co., Ltd.IYN2022-11-01
08800013511171C1-6CAlpinion Medical Systems Co., Ltd.IYN2022-07-15
08800013511164C1-7GTAlpinion Medical Systems Co., Ltd.IYN2022-02-05
08800013542007X-CUBE i8Alpinion Medical Systems Co., Ltd.IYN2022-02-05
08800013543004X-CUBE i9Alpinion Medical Systems Co., Ltd.IYN2022-02-05
08800076600119SC1FCUIYN2021-11-01
08800076600133Sono ChampionFCUIYN2021-11-01
08800076600140Sono ChangerFCUIYN2021-11-01
08800076600157Sono dot AIFCUIYN2021-11-01
08800076600010eZono1000FCUIYN2021-10-29
08800076600027Sonovation1LFCUIYN2021-10-29
08800076600034SOFRA1LFCUIYN2021-10-29
08800076600041SonoInfra1LFCUIYN2021-10-29