FlexTube 4 mm
- Primary DI
- EFIAE0121061
- Brand
- FlexTube 4 mm
- Company
- Fiagon GmbH
- Model
- 1
- Device description
- The products are variants of a navigated suction instrument for image guided surgical proceduresThe instruments are intended as an aid for precisely locating anatomical structures in either open or percutaneousprocedures. They are indicated for use with the Fiagon Navigation system using electromagnetic navigation.The instrument are indicated for any medical condition in which the use of stereotactic surgery may be appropriate,and where reference to a rigid anatomical structure in the field of ENT surgery can be identified relative to a CT orMR based model of the anatomy.
- Published
- 2016-08-08
- Public version status
- Update
- Distribution status
- Not in Commercial Distribution
- MRI safety
- MR Unsafe
- Rx
- true
Contact Domains#
Product Codes#
| Code | Name |
|---|---|
| PGW | Ear, Nose, And Throat Stereotaxic Instrument |
Product Code Classifications#
| Code | Device | Specialty | Class |
|---|---|---|---|
| PGW | Ear, Nose, And Throat Stereotaxic Instrument | Neurology | 2 |
Premarket Submissions#
| Submission | Supplement |
|---|---|
| K141456 | 000 |
Premarket Details#
Identifiers And Packaging#
| Identifier | Type | Agency | Package quantity | Status |
|---|---|---|---|---|
| EFIAE0121060 | Direct Marking | HIBCC | 0 | |
| EFIAE0121061 | Primary | HIBCC | 0 |
GMDN Terms#
| Term | Definition |
|---|---|
| Multi-purpose stereotactic surgery system | An assembly of devices that typically consists of a rigid frame, positioning and alignment components, workstation, and a calibrated guide mechanism for precisely positioning probes, other instruments, or implantable devices during a surgical procedure of more than one discipline [e.g., orthopaedic and ear/nose/throat (ENT)]. The system may include computerized functions to store diagnostic images used for image-guided surgery. |
Storage And Handling#
| Type | Low | High | Condition |
|---|---|---|---|
| Handling Environment Humidity | 30 Percent (%) Relative Humidity | 75 Percent (%) Relative Humidity | |
| Handling Environment Temperature | 15 Degrees Celsius | 35 Degrees Celsius | |
| Storage Environment Atmospheric Pressure | 70 KiloPascal | 106 KiloPascal |
Sterilization Methods#
| Method |
|---|
| Moist Heat or Steam Sterilization |
Contacts#
| Phone | |
|---|---|
| +13364282241 | support@fiagon.com |
Regulatory Flags#
- DUNS number
- 312623008
- Device count
- 1
- Serial number
- true
- Manufacturing date on label
- true
- Sterilization required before use
- true
Other Devices From This Company#
| Primary DI | Brand | Model | Catalog | Published |
|---|---|---|---|---|
| 04260759931314 | Flexarm Universal | E011973 | 2026-09-20 | |
| 04260759931697 | VirtuEye Pro | E011440 | E011440 | 2026-08-17 |
| EFIAE0135061 | VenSure Balloon Sinus Dilation System | 1 | E 01 3506 | 2021-06-11 |
| EFIAE0135161 | VenSure Nav Balloon Sinus Dilation System | 1 | 2021-06-11 | |
| 04260759931246 | VenSure Balloon Dilation System | 1 | E 01 3526 | 2022-11-10 |
| 04260759931680 | VenSure 4D Balloon Dilation System | 1 | E 01 3566 | 2025-09-18 |
| 04260759931260 | VenSure Nav Balloon Dilation System | 1 | E 01 3546 | 2022-11-10 |
| 04260759931253 | VenSure Light Balloon Dilation System | 1 | E 01 3536 | 2022-10-14 |
| EFIAE0135921 | Vensure Inflation Device | 1 | E 01 3592 | 2022-01-21 |
| 04260759930003 | Integrated Headrest | E011970 | 2025-06-25 | |
| 04260759930133 | Navigation Unit Cube4D | E011106-HD/8 | E011106-HD/8 | 2025-01-16 |
| 04260759930157 | 4K Navigation Unit Cube4D | E011106-4K/8 | E011106-4K/8 | 2025-01-16 |
| 04260759930249 | Navigation Sensor | A011000 | A011000 | 2025-01-16 |
| 04260759930300 | FlexPointer | E012002 | E012002 | 2025-01-16 |
| 04260759930317 | FlexPointer 1.5 mm | E012004 | E012004 | 2025-01-16 |
| 04260759930324 | FlexTube 3mm | E012104 | E012104 | 2025-01-16 |
| 04260759930331 | FlexTube 4mm | E012106 | E012106 | 2025-01-16 |
| 04260759930348 | PointerTube Keat | E012107 | E012107 | 2025-01-16 |
| 04260759930355 | PointerTube Kennedy | E012108 | E012108 | 2025-01-16 |
| 04260759930447 | Localizer Adhesive Pad C-Type | E012202C | E012202C | 2025-01-16 |
Other Devices Sharing Product Codes#
| Primary DI | Brand | Company | Product code | Published |
|---|---|---|---|---|
| 04260759931314 | Flexarm Universal | Fiagon GmbH | PGW | 2026-09-20 |
| 04260759931697 | VirtuEye Pro | Fiagon GmbH | PGW | 2026-08-17 |
| 00199150054398 | StealthStation S8 | MEDTRONIC NAVIGATION, INC. | PGW | 2026-08-07 |
| 00199150006427 | Stealth AXiS | MEDTRONIC NAVIGATION, INC. | PGW | 2026-04-24 |
| 00763000738358 | AxiEM™ | MEDTRONIC NAVIGATION, INC. | PGW | 2026-02-15 |
| 00763000738365 | AxiEM™ | MEDTRONIC NAVIGATION, INC. | PGW | 2026-02-15 |
| 00763000738372 | AxiEM™ | MEDTRONIC NAVIGATION, INC. | PGW | 2026-02-15 |
| 00763000738389 | AxiEM™ | MEDTRONIC NAVIGATION, INC. | PGW | 2026-02-15 |
| 00763000738396 | AxiEM™ | MEDTRONIC NAVIGATION, INC. | PGW | 2026-02-15 |
| 04056481146702 | Curve Navigation | Brainlab SE | PGW | 2025-10-13 |
| 04260759930003 | Integrated Headrest | Fiagon GmbH | PGW | 2025-06-25 |
| 04260759930133 | Navigation Unit Cube4D | Fiagon GmbH | PGW | 2025-01-16 |
| 04260759930157 | 4K Navigation Unit Cube4D | Fiagon GmbH | PGW | 2025-01-16 |
| 04260759930249 | Navigation Sensor | Fiagon GmbH | PGW | 2025-01-16 |
| 04260759930300 | FlexPointer | Fiagon GmbH | PGW | 2025-01-16 |
| 04260759930317 | FlexPointer 1.5 mm | Fiagon GmbH | PGW | 2025-01-16 |
| 04260759930324 | FlexTube 3mm | Fiagon GmbH | PGW | 2025-01-16 |
| 04260759930331 | FlexTube 4mm | Fiagon GmbH | PGW | 2025-01-16 |
| 04260759930348 | PointerTube Keat | Fiagon GmbH | PGW | 2025-01-16 |
| 04260759930355 | PointerTube Kennedy | Fiagon GmbH | PGW | 2025-01-16 |
| 04260759930447 | Localizer Adhesive Pad C-Type | Fiagon GmbH | PGW | 2025-01-16 |
| 04260759930515 | Adhesive Pad | Fiagon GmbH | PGW | 2024-09-02 |
| 04260759930119 | RegistrationPointer | Fiagon GmbH | PGW | 2024-09-02 |
| 04260759930126 | VirtuEye | Fiagon GmbH | PGW | 2024-09-02 |
| 04260759930256 | Navigation Headrest Universal | Fiagon GmbH | PGW | 2024-09-02 |
| 04260759930362 | PointerShell 4 mm | Fiagon GmbH | PGW | 2024-09-02 |
| 04260759930379 | PointerShell 5 mm | Fiagon GmbH | PGW | 2024-09-02 |
| 04260759930386 | PointerShell 3 mm | Fiagon GmbH | PGW | 2024-09-02 |
| 04260759930393 | PointerShell Universal | Fiagon GmbH | PGW | 2024-09-02 |
| 14260759930512 | Adhesive Pad | Fiagon GmbH | PGW | 2024-09-02 |