GUDID EOBN270082S0

Corona 360 Radial Fiber, core 550µm, clad 578µm, fiber OD 1400µm, white Vestodur Jacket with length marking, customized connector, white bend protection, distal conical tip with silica capillary dome, capillary OD 1800µm, NA 0.22, length 2,6m +/-0,2m, sterile EO, disposable, double packed

OBERON GmbH Fiber Technologies

General/multiple surgical laser system beam guide, reusable
Primary Device IDEOBN270082S0
NIH Device Record Key4e922c89-eedf-4f32-9ebe-8b6bb0642e9e
Commercial Distribution StatusIn Commercial Distribution
Version Model NumberCorona 360 Radial Fiber 600µm
Company DUNS312889060
Company NameOBERON GmbH Fiber Technologies
Device Count1
DM Exemptfalse
Pre-market Exemptfalse
MRI Safety StatusLabeling does not contain MRI Safety Information
Human Cell/Tissue Productfalse
Device Kitfalse
Device Combination Productfalse
Single Usetrue
Lot Batchtrue
Serial Numberfalse
Manufacturing Datetrue
Expiration Datetrue
Donation Id Numberfalse
Contains Natural Rubber Latexfalse
Labeled No Natural Rubber Latexfalse
RX Perscriptiontrue
OTC Over-The-Counterfalse

Device Identifiers

Device Issuing AgencyDevice ID
HIBCCEOBN270082S0 [Primary]

FDA Pre-market Approvals/Notifications & deNovo

FDA Product Code

GEXPowered Laser Surgical Instrument

Sterilization

Steralize Prior To Usefalse
Device Is Steriletrue

Device Entry Metadata

Public Version StatusUpdate
Device Record StatusPublished
Public Version Number4
Public Version Date2018-07-06
Device Publish Date2017-02-18

Devices Manufactured by OBERON GmbH Fiber Technologies

EOBN220105S0 - NA2024-08-01 Laser Surgery Fiber, core 600µm, clad 660µm, fiber OD 890µm, blue Tefzel Jacket, freestanding SMA 905 connector with knurl nu
EOBN210180S0 - NA2024-07-25 Laser Surgery Fiber, core 365µm, clad 400µm, fiber OD 580µm, blue Tefzel Jacket, standard SMA 905 connector with knurl nut, b
EOBN210181S0 - NA2024-07-25 Laser Surgery Fiber, core 365µm, clad 400µm, fiber OD 580µm, blue Tefzel Jacket, standard SMA 905 connector with knurl nut, b
EOBN270190S0 - NA2024-06-19 Radial Emission Fiber, core 400µm, clad 420µm, fiber OD 950µm, white Tefzel Jacket with length marking, standard SMA 905 conn
EOBN270191S0 - NA2024-06-19 Radial Emission Fiber, core 550µm, clad 578µm, fiber OD 1300µm, white Tefzel Jacket with length marking, standard SMA 905 con
EOBN270192S0 - NA2024-06-19 Radial Emission Fiber, core 550µm, clad 578µm, fiber OD 1300µm, white Tefzel Jacket, standard SMA 905 connector with knurl nu
EOBN270518S0 - NA2024-06-19 Proctology - Hemorrhoid Fiber Probe, core 550µm, clad 578µm, fiber OD 1300µm, white Tefzel Jacket, standard SMA 905 connector
EOBN220138S0 - NA2024-02-01 Laser Surgery Fiber, core 600µm, clad 660µm, fiber OD 890µm, blue Tefzel Jacket, freestanding SMA 905 connector with knurl nu