MR Diffusion Perfusion Mismatch

Primary DI
EOLEMRDPMV1P00
Brand
MR Diffusion Perfusion Mismatch
Company
Olea Medical USA
Model
V1.0
Device description
MR Diffusion Perfusion Mismatch V1.0 is an automatic calculation tool indicated for use in radiology. The device is an image processing software allowing computation of parametric maps from (1) MR Diffusion-weighted imaging (DWI) and (2) MR Perfusion-weighted imaging (PWI) and extraction of volumes of interest based on numerical thresholds applied to the aforementioned maps. Computation of mismatch between extracted volumes is automatically provided.The device is intended to assist trained radiologists and surgeons in the imaging assessment workflow by extraction and communication of metrics from MR Diffusion-weighted imaging (DWI) and MR Perfusion-weighted imaging (PWI).The results of MR Diffusion Perfusion Mismatch V1.0 are intended to be used in conjunction with other patient information and, based on professional judgment, to assist the clinician in the medical imaging assessment.MR Diffusion Perfusion Mismatch V1.0 can be integrated and deployed through technical platforms.
Published
2023-03-08
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
LLZSystem, Image Processing, Radiological

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
LLZSystem, Image Processing, RadiologicalRadiology2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K223502000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K223502000MR Diffusion Perfusion Mismatch V1.0Olea Medical2023-01-13LLZ

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
EOLEMRDPMV1P00PrimaryHIBCC0

GMDN Terms#

Term, Definition table
TermDefinition
Radiology PACS softwareAn individual software application intended to be installed on a central server as part of a picture archiving and communication system (PACS) to allow storage, retrieval, analysis, and management of radiological images. It is designed specifically for use within radiology.

Sterilization Methods#

Method table
Method

Contacts#

Phone, Email table
PhoneEmail
+33442712420contact@olea-medical.com

Regulatory Flags#

DUNS number
047358761
Device count
1
Lot or batch
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
EOLENEUROINSIGHTV1P00Neuro InsightV1.0AP-NI-MR or AP-NI-NP-MR or AP-NI-NS-MR2026-04-13
EOLENEUROVASIV1P00Neurovascular InsightV1.0AP-NVI-CT or AP-NVI-MR2026-04-13
EOLECTPERFUSIONV1P00CT PerfusionV1.02023-07-31
EOLENEUROVASV1P00Olea S.I.A. NeurovascularV1.02023-07-31
EOLEMRDFMV1P00MR DWI/FLAIR MeasurementV1.02023-05-04
EOLEAUTOMATIONV1P50Automation Platform V1.51.52022-11-22
EOLEOLEASIAV1P00Olea S.I.A V1.01.02022-11-22
EOLEFMRIV1P00FUNCTIONAL MRV1.02022-09-22
EOLEBREASTSCAPEV1P00BREASTSCAPEV1.02021-09-14
EOLEAUTOMATIONV1P01Automation Platform1.02019-11-25
EOLEOLEASPHEREV2P31OLEA SPHERE2.32017-05-12
EOLEOLEASPHEREV3P01OLEA SPHERE3.02016-09-22

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
B359OAIIV2026051RamsoftRamsoft IncLLZ2026-06-04
M722CD26127V260970ClearRead CT DockerRiverain Technologies, Inc.LLZ2026-05-28
17540262200096Change Healthcare Stratus Imaging Diagnostic ViewerChange Healthcare Canada CompanyLLZ2026-05-27
75401622522101Synthesis Vision ViewerSynthesis Health Intelligence IncLLZ2026-05-27
08437021722093ADAS 3DADAS3D MEDICAL S.L.LLZ2026-05-12
08800133400003ZeTTA PACSTae Young Soft Co., Ltd.LLZ2026-05-12
08033837938835no brandCEFLA SOCIETA' COOPERATIVALLZ2026-05-11
G725QFR300QFRQFR Solutions B.V.LLZ2026-05-11
G725QFR310QFRQFR Solutions B.V.LLZ2026-05-11
08800130800080Laon OrthoLaon Medi Inc.LLZ2026-05-07
G713ELU0010ElucisRealize Medical Inc.LLZ2026-05-07
08437021468045QP-Brain®QUIBIM SOCIEDAD LIMITADA.LLZ2026-05-06
08437023642016NemoCastSOFTWARE NEMOTEC SLLLZ2026-04-23
08437023642023NemoFABSOFTWARE NEMOTEC SLLLZ2026-04-23
M722C26103V260970ClearRead CT ServerRiverain Technologies, Inc.LLZ2026-04-20
M722CC26103V260970ClearRead CT ConsoleRiverain Technologies, Inc.LLZ2026-04-20
M722CD26103V260970ClearRead CT DockerRiverain Technologies, Inc.LLZ2026-04-20
M722CP26104V261040ClearRead CT Platform DockerRiverain Technologies, Inc.LLZ2026-04-20
EOLENEUROINSIGHTV1P00Neuro InsightOlea Medical USALLZ2026-04-13
EOLENEUROVASIV1P00Neurovascular InsightOlea Medical USALLZ2026-04-13
08056304455864Caas QardiaPie Medical Imaging B.V.LLZ2026-04-03
08800290066784EVO Q10 Diagnostic Ultrasound SystemSAMSUNG MEDISON CO., LTD.LLZ2026-04-03
08800340506147EVO QH10 Diagnostic Ultrasound SystemSAMSUNG MEDISON CO., LTD.LLZ2026-04-03
08800340509988EVO XQ10 Diagnostic Ultrasound SystemSAMSUNG MEDISON CO., LTD.LLZ2026-04-03
08800066200619JLK-AILINKJLK, Inc.LLZ2026-03-25
08800066200787JLK-CTPJLK, Inc.LLZ2026-03-25
08800066200794JLK-PWIJLK, Inc.LLZ2026-03-25
08800130400303Neurophet AQUA AD PlusNEUROPHET Inc.LLZ2026-02-24
08800290027471EV2-12SAMSUNG MEDISON CO., LTD.LLZ2026-01-28
08800290041767EA2-11AVSAMSUNG MEDISON CO., LTD.LLZ2026-01-28