Saneso

Primary DI
G347SAN1CA0
Brand
Saneso
Company
Saneso Inc.
Model
SAN1C-A
Device description
Single Camera Colonoscope with high definition imaging,140-160 degree FOV, lens wash system, dedicated tissue wash system, LED lighting, select band imaging, a vertical & horizontal bending radius of 180 & 160 degrees.
Published
2022-11-11
Public version status
New
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information

Contact Domains#

Product Codes#

Code, Name table
CodeName
FDFColonoscope And Accessories, Flexible/Rigid

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
FDFColonoscope And Accessories, Flexible/RigidGastroenterology, Urology2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K210052000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K210052000Saneso Colonoscope 360-A (Model: with/without Select Band Imaging (SBI) and with/without Dual Band Imaging(DBI)), Saneso Single Camera Colonoscope-A (Model: with/without Select Band Imaging (SBI)), Saneso Gastroscope 360-A (Model: with/without Select Band Imaging (SBI) and with/without Dual Band Imaging(DBI)), Saneso Single Camera Gastroscope-A (Model: with/without Select Band Imaging (SBI))Saneso, Inc.2022-04-01FDF

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
G347SAN1CA0PrimaryHIBCC0

GMDN Terms#

Term, Definition table
TermDefinition
Flexible video colonoscope, reusableAn endoscope with a flexible inserted portion intended for the visual examination and treatment of the entire colon [lower gastrointestinal (GI) tract]. It is inserted through the anus during colonoscopy. Anatomical images are transmitted to a monitor for viewing by a video system with a charge-coupled device (CCD) chip at the distal end of the endoscope. This device is commonly used to examine the lining of the colon or to evaluate altered bowel habits, colonic cancer, polyps, diverticular disease, occult or frank blood in stools, or unexplained anaemia. This is a reusable device.

Device Sizes#

Type, Value, Unit table
TypeValueUnit
Length1680Millimeter
Outer Diameter11.6Millimeter

Sterilization Methods#

Method table
Method

Contacts#

Phone, Email table
PhoneEmail
6812984613koushik.garapati@saneso.com

Regulatory Flags#

DUNS number
117059270
Device count
1
Serial number
true
Manufacturing date on label
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
G347SAN1GA0SanesoSAN1G-A2022-11-11
G347SBA0SanesoG347SBA2022-11-11
G347SAN360CA0SanesoSAN360C-A2022-11-04
G347SAN360GA0SanesoSAN360G-A2022-11-04

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
06973786293222Disposable Distal End Tape HoodShanghai SeeGen Photoelectric Technology Co.,Ltd. (YinDu Road Factory)FDF2026-06-04
06973786293246Disposable Distal End Tape HoodShanghai SeeGen Photoelectric Technology Co.,Ltd. (YinDu Road Factory)FDF2026-06-04
07290016992113Aer-O-Scope Disposable ColonoscopeG.I. VIEW LTDFDF2026-05-27
00724995246723DEFENDO Air/Water/Suction and Biopsy ValveMEDIVATORS INC.FDF2026-04-06
00724995246730DEFENDO Air/Water and Suction ValvesMEDIVATORS INC.FDF2026-04-06
00724995246747DEFENDO Valve and Connector KitMEDIVATORS INC.FDF2026-04-06
00724995246754Defendo Single Use Valve KitMEDIVATORS INC.FDF2026-04-06
00724995246761Defendo Single Use Valve KitMEDIVATORS INC.FDF2026-04-06
00724995246778Defendo Single Use Valve KitMEDIVATORS INC.FDF2026-04-06
00724995246785Defendo Single Use Valve KitMEDIVATORS INC.FDF2026-04-06
00724995246792DEFENDO Valve and Connector KitMEDIVATORS INC.FDF2026-04-06
00724995246808DEFENDO Air/Water/Suction and Biopsy ValveMEDIVATORS INC.FDF2026-04-06
00724995246815DEFENDO Air/Water and Suction ValvesMEDIVATORS INC.FDF2026-04-06
04547410566253FUJIFILMFUJIFILM CORPORATIONFDF2026-02-27
04547410566291FUJIFILMFUJIFILM CORPORATIONFDF2026-02-27
04547410566338FUJIFILMFUJIFILM CORPORATIONFDF2026-02-27
04547410566376FUJIFILMFUJIFILM CORPORATIONFDF2026-02-27
04547410566413FUJIFILMFUJIFILM CORPORATIONFDF2026-02-27
04547410566451FUJIFILMFUJIFILM CORPORATIONFDF2026-02-27
04547410477245FUJIFILMFUJIFILM CORPORATIONFDF2025-06-30
04547410477276FUJIFILMFUJIFILM CORPORATIONFDF2025-06-30
04547410477306FUJIFILMFUJIFILM CORPORATIONFDF2025-06-30
04953170423628GASTROINTESTINAL VIDEOSCOPEOLYMPUS MEDICAL SYSTEMS CORP.FDF2025-05-26
04953170454356DISPOSABLE DISTAL ATTACHMENTOLYMPUS MEDICAL SYSTEMS CORP.FDF2025-05-13
04953170454271DISPOSABLE DISTAL ATTACHMENTOLYMPUS MEDICAL SYSTEMS CORP.FDF2025-05-12
04953170454288DISPOSABLE DISTAL ATTACHMENTOLYMPUS MEDICAL SYSTEMS CORP.FDF2025-05-12
04953170454295DISPOSABLE DISTAL ATTACHMENTOLYMPUS MEDICAL SYSTEMS CORP.FDF2025-05-12
04953170454301DISPOSABLE DISTAL ATTACHMENTOLYMPUS MEDICAL SYSTEMS CORP.FDF2025-05-12
04953170454325DISPOSABLE DISTAL ATTACHMENTOLYMPUS MEDICAL SYSTEMS CORP.FDF2025-05-12
04953170454349DISPOSABLE DISTAL ATTACHMENTOLYMPUS MEDICAL SYSTEMS CORP.FDF2025-05-12