AngioDynamics

Primary DI
H965251840
Brand
AngioDynamics
Company
NAVILYST MEDICAL, INC.
Model
25184
Device description
AngioVac Cannula
Published
2016-09-20
Public version status
Update
Distribution status
Not in Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true
Sterile
true
Single use
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
DWFCATHETER, CANNULA AND TUBING, VASCULAR, CARDIOPULMONARY BYPASS

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
DWFCatheter, Cannula And Tubing, Vascular, Cardiopulmonary BypassCardiovascular2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K133445000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K133445000ANGIOVAC CANNULAVortex Medical, Inc.2014-03-05DWF

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
H965251840PrimaryHIBCC0

GMDN Terms#

Term, Definition table
TermDefinition
Cardiopulmonary bypass cannula, venousA sterile, semi-rigid or rigid tube intended to be used during open heart surgery where it is surgically inserted, typically into the right atrium and superior/inferior vena cava, to serve as a channel for the transport of blood to a cardiopulmonary bypass system (heart-lung machine) tubing circuit where the blood is pumped and oxygenated. It is typically a moulded plastic tube with stainless steel wire reinforcement, to prevent kinking/collapse, and having multiple perforations at the distal end and possibly a non-reinforced clamping site at the proximal end. It is typically inserted using a compatible trocar. This is a single-use device.

Device Sizes#

Type, Value, Unit table
TypeValueUnit
Catheter Gauge22French
Length80Centimeter
Outer Diameter24Millimeter

Sterilization Methods#

Method table
Method

Contacts#

Phone, Email table
PhoneEmail
+1(518)795-1676dgreer@angiodynamics.com

Regulatory Flags#

DUNS number
809699023
Device count
1
Lot or batch
true
Expiration date on label
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
H787LG191005LifeguardLG-19-1002016-09-20
H787LG19755LifeguardLG-19-752016-09-20
H787LG201005LifeguardLG-20-1002016-09-20
H787LG201505LifeguardLG-20-1502016-09-20
H787LG20505LifeguardLG-20-502016-09-20
H787LG20755LifeguardLG-20-752016-09-20
H787LG221005LifeguardLG-22-1002016-09-20
H787LG22505LifeguardLG-22-502016-09-20
H787LG22755LifeguardLG-22-752016-09-20
H787LPS30045LifeportLPS 30042016-09-20
H787LPS30055LifeportLPS 30052016-09-20
H787LPS30065LifeportLPS 30062016-09-20
H787LPS30075LifeportLPS 30072016-09-20
H787LPS30085LifeportLPS 30082016-09-20
H787LPS30095LifeportLPS 30092016-09-20
H787LPS30175LifeportLPS 30172016-09-20
H787LPS30235LifeportLPS 30232016-09-20
H787LPS30255LifeportLPS 30252016-09-20
H787CT50LPBANFVI0BioFlo VortexCT50LPBANFVI2020-05-29
H787CT50LPBAVI0BioFlo VortexCT50LPBAVI2020-05-29

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00199150083855NAMEDTRONIC, INC.DWF2026-06-08
00199150083992NAMEDTRONIC, INC.DWF2026-06-08
00199150084180NAMEDTRONIC, INC.DWF2026-06-08
00824846000020NAMEDTRONIC, INC.DWF2026-06-08
00824846000983NAMEDTRONIC, INC.DWF2026-06-08
00824846001027NAMEDTRONIC, INC.DWF2026-06-08
00824846001041NAMEDTRONIC, INC.DWF2026-06-08
00824846001065NAMEDTRONIC, INC.DWF2026-06-08
00199150083077NAMEDTRONIC, INC.DWF2026-05-30
00199150083121NAMEDTRONIC, INC.DWF2026-05-30
00199150083381NAMEDTRONIC, INC.DWF2026-05-30
00199150083442NAMEDTRONIC, INC.DWF2026-05-30
00199150083534NAMEDTRONIC, INC.DWF2026-05-30
00199150083718NAMEDTRONIC, INC.DWF2026-05-30
00199150083763NAMEDTRONIC, INC.DWF2026-05-30
00199150083794NAMEDTRONIC, INC.DWF2026-05-30
00199150083800NAMEDTRONIC, INC.DWF2026-05-30
00199150083817NAMEDTRONIC, INC.DWF2026-05-30
00199150083893NAMEDTRONIC, INC.DWF2026-05-30
00199150083985NAMEDTRONIC, INC.DWF2026-05-30
18051160302878Quantum SuperPAC Tubing Set - SP05E-BBSPECTRUM MEDICAL SRLDWF2026-05-27
00199150078455NAMEDTRONIC, INC.DWF2026-04-26
08033178017190Cardioplegia CannulaSORIN GROUP ITALIA SRLDWF2026-02-11
08033178017206Cardioplegia CannulaSORIN GROUP ITALIA SRLDWF2026-02-11
08033178017213Cardioplegia CannulaSORIN GROUP ITALIA SRLDWF2026-02-11
08033178017220Cardioplegia CannulaSORIN GROUP ITALIA SRLDWF2026-02-11
08033178017237Cardioplegia CannulaSORIN GROUP ITALIA SRLDWF2026-02-11
08033178017244Cardioplegia CannulaSORIN GROUP ITALIA SRLDWF2026-02-11
08033178017251Cardioplegia CannulaSORIN GROUP ITALIA SRLDWF2026-02-11
08033178017268Cardioplegia CannulaSORIN GROUP ITALIA SRLDWF2026-02-11