Integra Flow Regulating Valve Low Flow

Primary DI
M2729OS512P1
Brand
Integra Flow Regulating Valve Low Flow
Company
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
Model
9OS512P
Catalog number
9OS512P
Device description
The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hydrocephalus valve systems for controlled cerebrospinal fluid (CSF) drainage from the ventricles to the peritoneal cavity or other appropriate drainage site such as the heart’s right atrium. Unlike conventional valves, the Integra Flow Regulating Valve Low Flow is a variable resistance valve that maintains drainage at a constant rate, between 8 and 17 ml/hr, within the physiological range of intracranial pressure.
Published
2015-10-01
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
MR Conditional
Rx
true
OTC
false
Sterile
true
Single use
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
JXGShunt, central nervous system and components

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
JXGShunt, Central Nervous System And ComponentsNeurology2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K093968000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K093968000OSV II LOW FLOW LOW PRO VALVEIntegra LifeSciences Corporation2010-01-22JXG

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
10381780036036PrimaryGS10
M2729OS512P1SecondaryHIBCC0

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized table
Source identifierGTIN-14 normalized
1038178003603610381780036036

GMDN Terms#

Term, Definition table
TermDefinition
Ventriculo-peritoneal/atrial shuntAn implantable device intended to divert excessive cerebrospinal fluid (CSF) from the brain ventricles to either the peritoneal cavity or the heart right atrium (i.e., dual-capability), where it can be absorbed into the body, as a treatment for increased intracranial pressure (e.g., caused by hydrocephalus). It consists of: 1) an intracerebral ventricular catheter through which CSF flows; 2) a mechanical shunt valve that typically opens at a pre-set pressure; and 3) a peritoneal/atrial catheter that channels the CSF to the peritoneal cavity or right atrium; some types have a port/reservoir for hypodermic sampling/infusion. Disposable devices associated with implantation may be included.

Device Sizes#

Type, Value, Unit table
TypeValueUnit
Device Size Text, specify0

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Special Storage Condition, Specify00Room temperature

Sterilization Methods#

Method table
Method

Contacts#

Phone, Email table
PhoneEmail
+1(800)654-2873custsvcnj@integralife.com

Regulatory Flags#

DUNS number
531408342
Device count
1
DM exempt
false
Premarket exempt
false
HCT/P
false
Kit
true
Combination product
false
Lot or batch
true
Serial number
false
Manufacturing date on label
true
Expiration date on label
true
Donation ID number
false
Contains natural rubber latex
false
No natural rubber latex
true
Sterilization required before use
false

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
10381780250371Licox ®VK522016-08-04
10381780023715Integra®910110A910110A2015-10-01
10381780034117External Drainage Set9101092016-06-24
10381780034131Drainage Accessory Kit9101229101222015-10-01
10381780034186Integral Drainage Set9104109104102015-10-01
10381780035541External Drainage Set910116A910116A2015-10-01
10381780035558External Drainage Set910116D910116D2015-10-01
10381780035602Integral Drainage Set910410B910410B2015-10-01
10381780034124Lumbar Catheter Accessory Kit9101219101212015-10-01
10381780034193Integral Drainage Set9104129104122015-10-01
10381780034209Integral Drainage Set9104209104202015-10-01
10381780035527External Drainage Set910112A910112A2015-10-01
10381780035565External Drainage Set910120A910120A2015-10-01
10381780035589External Drainage Set910123A910123A2015-10-01
10381780457305Contour-Flex Valve and Shunt System11811118112018-01-12
10381780457312Contour-Flex Valve and Shunt System11812118122018-01-12
10381780457329Contour-Flex Valve and Shunt System11813118132018-01-12
10381780457459Contour-Flex Valve and Shunt System14085140852018-01-12
10381780457466Contour-Flex Valve and Shunt System14086140862018-01-12
10381780457473Contour-Flex Valve and Shunt System14087140872018-01-12

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
10381780535362CODMAN® CERTAS®Integra LifeSciences Switzerland SàrlJXG2025-06-30
10381780535379CODMAN® CERTAS®Integra LifeSciences Switzerland SàrlJXG2025-06-30
10381780535881CODMAN® CERTAS®Integra LifeSciences Switzerland SàrlJXG2025-06-30
10381780535928CODMAN® CERTAS®Integra LifeSciences Switzerland SàrlJXG2025-06-30
10381780535942CODMAN® CERTAS®Integra LifeSciences Switzerland SàrlJXG2025-06-30
10381780535393CODMAN® CERTAS® PlusIntegra LifeSciences Switzerland SàrlJXG2024-11-20
10381780535430CODMAN® CERTAS® PlusIntegra LifeSciences Switzerland SàrlJXG2024-11-20
10381780535829CODMAN® CERTAS® PlusIntegra LifeSciences Switzerland SàrlJXG2024-11-20
10381780535867CODMAN® CERTAS® PlusIntegra LifeSciences Switzerland SàrlJXG2024-11-20
10381780537014CODMAN® BACTISEAL®INTEGRA LIFESCIENCES PRODUCTION CORPORATIONJXG2024-11-20
10381780537021CODMAN® BACTISEAL®INTEGRA LIFESCIENCES PRODUCTION CORPORATIONJXG2024-11-20
10381780537038CODMAN® BACTISEAL®INTEGRA LIFESCIENCES PRODUCTION CORPORATIONJXG2024-11-20
10381780537045CODMAN® BACTISEAL®INTEGRA LIFESCIENCES PRODUCTION CORPORATIONJXG2024-11-20
10381780537069CODMAN® BACTISEAL®INTEGRA LIFESCIENCES PRODUCTION CORPORATIONJXG2024-11-20
10381780537106CODMAN® BACTISEAL®INTEGRA LIFESCIENCES PRODUCTION CORPORATIONJXG2024-11-20
10381780537144CODMAN® HAKIM® BACTISEAL®INTEGRA LIFESCIENCES PRODUCTION CORPORATIONJXG2024-11-20
10381780537151CODMAN® BACTISEAL®INTEGRA LIFESCIENCES PRODUCTION CORPORATIONJXG2024-11-20
10381780537496Hermetic™Integra Lifesciences CorporationJXG2024-06-28
10381780538325CODMAN® VPV®INTEGRA LIFESCIENCES PRODUCTION CORPORATIONJXG2024-06-28
10381780537489N/AIntegra Lifesciences CorporationJXG2024-06-21
10381780536734CODMAN®INTEGRA LIFESCIENCES PRODUCTION CORPORATIONJXG2024-05-29
10381780536741CODMAN®INTEGRA LIFESCIENCES PRODUCTION CORPORATIONJXG2024-05-29
10381780536758CODMAN® ACCU-FLO®INTEGRA LIFESCIENCES PRODUCTION CORPORATIONJXG2024-05-29
10381780536765CODMAN® ACCU-FLO®INTEGRA LIFESCIENCES PRODUCTION CORPORATIONJXG2024-05-29
10381780536789CODMAN® ACCU-FLO®INTEGRA LIFESCIENCES PRODUCTION CORPORATIONJXG2024-05-29
10381780536819CODMAN® ACCU-FLO®INTEGRA LIFESCIENCES PRODUCTION CORPORATIONJXG2024-05-29
10381780536840CODMAN® ACCU-FLO®INTEGRA LIFESCIENCES PRODUCTION CORPORATIONJXG2024-05-29
10381780536864CODMAN® ACCU-FLO®INTEGRA LIFESCIENCES PRODUCTION CORPORATIONJXG2024-05-29
10381780536901CODMAN® ACCU-FLO®INTEGRA LIFESCIENCES PRODUCTION CORPORATIONJXG2024-05-29
10381780536949CODMAN® ACCU-FLO®INTEGRA LIFESCIENCES PRODUCTION CORPORATIONJXG2024-05-29