ISO 14243-1 Second edition 2009-11-15

Standard Organization:

ISO 14243-1 Second edition 2009-11-15
Implants for surgery - Wear of total knee-joint prostheses - Part 1: Loading and displacement parameters for wear-testing machines with load control and corresponding environmental conditions for test

Recognition Date2014-01-30
Recognition List034
Recognition Number11-222
Extent Complete standard
Standards Orgs ISO International Organization for Standardization https://www.iso.org/
STG Orthopedic
FDA Tech .stds { color: #000000; float: center; width: 950px; margin: 0px 25px 0px 0px; } .stds-middle { color: #000000; float: center; width: 575px; margin: 0px 50px 50px 50px; } /* .stds-left { float: left; margin: 9px 30px 0px 0; } */ .stds-left { color: #000000; float: left; width: 700px; margin: 9px 0px 0px 0px; } .stds-search-left { float: left; width: 610px; margin: 9px 30px 0px 0; } .stds-search-right { float: right; width: 190px; margin: 9px 18px 0 0; padding: 8px 12px 10px 12px; background-color: #f9f9f3; border: 1px solid #b0b0b0; -webkit-border-radius: 6px; -moz-border-radius: 6px; border-radius: 6px; } .stds-right { color: #000000; float: right; width: 170px; margin: 9px 18px 0 0; padding: 8px 12px 10px 12px; background-color: #f3f3f3; border: 1px solid #b0b0b0; border-radius: 6px; } .stds-intro { margin: 0px 0px 18px 0px; padding: 5px 12px 12px 12px; background-color: #e8eff5; border: 1px solid #b0b0b0; border-radius: 6px; } #stds_nr-form { margin-top: 18px; padding-top: 12px; border-top: 1px dashed #b0b0b0; } #stds-form { table-layout:fixed; width: 700px; font-size: 11px; border: 1px solid #b0b0b0; background-color: #f9f9f3; } #stds-form-title{ padding: 3px 3px 3px 3px; width: 100%; background-color: #e8eff5; border-bottom: 1px solid #b0b0b0; margin-top: 0px; } #stds-form-title-left { font-size: 13px; font-weight:normal; } #stds-form-title-right { /*float: right;*/ font-size: 11px; padding: 0px 0px 0px 500px; } #stds-form-results-right { /*float: right;*/ font-size: 11px; padding: 0px 0px 0px 600px; } #stds-search { height: 18px; margin: 0px; padding: 3px 10px; border: 1px solid #b0b0b0; font-size: 12px; color: #484138; } #stds-search:focus, #stds-search:hover { -webkit-box-shadow: 0 0px 6px rgba(0,0,0,.1); -moz-box-shadow: 0 0px 6px rgba(0,0,0,.1); box-shadow: 0 0px 6px rgba(0,0,0,.1); } #stds-results-number { margin-bottom: 12px; font-size: 10px; font-weight: bold; } #stds-results-table { margin-left:auto; margin-right:auto; text-align:left; padding: 0; border-collapse:collapse; table-layout:fixed; background-color: #f9f9f3; border-color: #b0b0b0; border-width: 0 0 1px 1px; border-style: solid; } #stds-results-table th { padding: 6px 12px; background-color: #f9f9f3; border-color: #b0b0b0; border-width: 1px 1px 0 0; border-style: solid; font-size: 12px; } #stds-results-table td { padding: 6px 12px; border-color: #b0b0b0; border-width: 1px 1px 0 0; border-style: solid; text-transform: capitalize; } #stds-results-table tr:nth-child(odd) { /* background-color: #f3f3f3; */ } .sort { float: right; margin: 0px 10px 0px 0px; padding: 0px 5px 5px 5px; } /* .sort { float: right; margin-top: 5px;} */ .sort a { color: #484138; } .sort a:hover { color: #0f2a8c; } Recognized Consensus Standards // Quick Links: Skip to main page content Skip to Search Skip to Topics Menu Skip to Common Links U.S. Food & Drug Administration   Follow FDA En Español Search FDA   Home Food Drugs Medical Devices Radiation-Emitting Products Vaccines, Blood & Biologics Animal & Veterinary Cosmetics Tobacco Products   Recognized Consensus Standards var MP = { Version: '1.0.22', Domains: {'es':'esp.fda.gov'}, SrcLang: 'en', UrlLang: 'mp_js_current_lang', SrcUrl: unescape('mp_js_orgin_url'), init: function(){ if (MP.UrlLang.indexOf('p_js_')==1) { MP.SrcUrl=window.top.document.location.href; MP.UrlLang=MP.SrcLang; } }, getCookie: function(name){ var start=document.cookie.indexOf(name+'='); if(start < 0) return null; start=start+name.length+1; var end=document.cookie.indexOf(';', start); if(end < 0) end=document.cookie.length; while (document.cookie.charAt(start)==' '){ start++; } return unescape(document.cookie.substring(start,end)); }, setCookie: function(name,value,path,domain){ var cookie=name+'='+escape(value); if(path)cookie+='; path='+path; if(domain)cookie+='; domain='+domain; var now=new Date(); now.setTime(now.getTime()+1000*60*60*24*365); cookie+='; expires='+now.toUTCString(); document.cookie=cookie; }, switchLanguage: function(lang){ if(lang!=MP.SrcLang){ var script=document.createElement('SCRIPT'); script.src=location.protocol+'//'+MP.Domains[lang]+'/'+MP.SrcLang+lang+'/?1023749632;'+encodeURIComponent(MP.SrcUrl); document.body.appendChild(script); } else if(lang==MP.SrcLang && MP.UrlLang!=MP.SrcLang){ var script=document.createElement('SCRIPT'); script.src=location.protocol+'//'+MP.Domains[MP.UrlLang]+'/'+MP.SrcLang+MP.UrlLang+'/?1023749634;'+encodeURIComponent(location.href); document.body.appendChild(script); } return false; }, switchToLang: function(url) { window.top.location.href=url; } }; var addthis_config = {data_track_clickback: true, ui_508_compliant: true, services_compact: 'facebook, twitter, linkedin, pinterest_share, email', services_exclude: 'print', image_container: "#user_provided" } ; FDA Home Medical Devices Databases -

Rationale:

This standard is relevant to medical devices and is recognized on its scientific and technical merit and/or because it supports existing regulatory policies.

Scope:

This part of ISO 14243 specifies the flexion/extension relative angular movement between articulating components, the pattern of the applied force, speed and duration of testing, sample configuration and test environment to be used for the wear testing of total knee-joint prostheses in wear-testing machines with load control.

Code of Federal Regulations:

Regulation Number Device Name Device Class Product Code
§888.3565 Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uncemented, Porous, Coated, Polymer/Metal/Polymer Class 2 MBH
§888.3560 Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uhmwpe, Pegged, Cemented, Polymer/Metal/Polymer Class 2 MBV
§888.3560 Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer Class 2 JWH
§888.3550 Prosthesis, Knee, Patello/Femorotibial, Constrained, Cemented, Polymer/Metal/Metal Class 3 KRP
§888.3550 Prosthesis, Knee, Patello/Femorotibial, Constrained, Cemented, Polymer/Metal/Polymer Class 2 KRQ
§888.3530 Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Metal/Polymer Class 2 HRY
§888.3520 Prosthesis, Knee, Femorotibial, Non-Constrained, Cemented, Metal/Polymer Class 2 HSX
§888.3510 Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer Class 2 KRO
§888.3500 Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Metal/Composite Class 2 KYK
§888.3490 Prosthesis, Knee, Femorotibial, Non-Constrained, Metal/Composite Cemented Class 2 KTX
§888.3490 Prosthesis, Knee, Non-Constrained (Metal-Carbon Reinforced Polyethylene) Cemented Class 2 KMB
§888.3480 Metal Cemented Constrained Femorotibial Knee Prosthesis Class 3 KRN
Unclassified Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uncemented, Polymer/Metal/Polymer Class 3 LXY
Unclassified Prosthesis, Knee, Patello/Femorotibial, Unconstrained, Uncemented, Porous, Coated, Polymer/Metal/Polymer Class 3 MBD

FDA Guidance:

Class II Special Controls Guidance Document: Knee Joint Patellofemorotibial and Femorotibial Metal/Polymer Porous-Coated Uncemented Prostheses; Guidance for Industry and FDA, January 16, 2003