A portable non-electronic device intended to mix ambient air with compressed oxygen (O2) to generate a flow of oxygen rich air to a patient with adjustable inspired oxygen concentration (FiO2) [e.g., 28-100%] and adjustable flow rate, for continuous positiv...
An electrically-powered device designed to deliver heated and humidified ambient air or air/oxygen to a patient during both: 1) high-flow (exceeding peak inspiratory flow) respiratory therapy; and 2) bi-level positive airway pressure (BPAP). It consists of ...
An electrically-powered device that is a component of a high-flow respiratory assembly designed to generate a high-flow (exceeding peak inspiratory flow) of ambient air or air/oxygen for delivery to a patient in a peri-anaesthesia environment or experiencin...
A mains electricity (AC-powered) device intended to be used as part of a circulating-air whole-body heating system to filter, and control/regulate the temperature and flow of room air through a connected patient-applied pad (not included), for heating a pat...
A ventilated laboratory enclosure designed to prevent airborne biological contamination of laboratory specimens contained within, and personnel handling the specimen, by creating a barrier with a forced flow of uniform-velocity and parallel-direction air. I...
A mains electricity (AC-powered) device intended to be used as part of a circulating-air whole-body heating/cooling system to filter, and control/regulate the temperature and flow of room air through a connected patient-applied pad (not included), for heati...
An electrically-powered device designed to filter air [usually through a high-efficiency particulate air (HEPA) filter] in surgical theatres by producing a directed, non-turbulent flow of clean air to provide an area free of contaminants and reduce the risk...
An electrically-powered device intended to be used as part of an external circulating-air core temperature regulation system to filter, and control/regulate the temperature and flow of room air through a connected patient-applied pad (not included), to both...
An air-handling unit designed for use in surgical theatres to produce a directed, non-turbulent flow of clean air and thereby provide an area free of contaminants to reduce the possibility of infection to the patient. The air is filtered, usually through a ...
A portable non-electronic device intended to mix ambient air with compressed oxygen (O2) to generate a flow of oxygen rich air to a patient at a pre-set (non-adjustable) inspired oxygen concentration (FiO2) [e.g., pre-set at 28-33%], for continuous positive...
A mains electricity (AC-powered) device designed to deliver high-flow (exceeding peak inspiratory flow) heated and humidified ambient air or air/oxygen to a patient as therapy for a respiratory disorder [e.g., chronic obstructive pulmonary disease (COPD), b...
An electrically-powered device designed to deliver high-flow (exceeding peak inspiratory flow) heated and humidified ambient air or air/oxygen, at a manually set oxygen concentration (FiO2), to a spontaneously breathing patient. It is intended for use by a ...
An electrically-powered device designed to deliver high-flow (exceeding peak inspiratory flow) heated and humidified ambient air or air/oxygen to a patient in a peri-anaesthesia environment or experiencing a respiratory disorder [e.g., chronic obstructive p...
A device intended to regulate the flow of a medical gas [e.g., oxygen (O2), carbon dioxide (CO2), nitrous oxide (N2O), helium/oxygen gas mixture (heliox), medical air] during various procedures (e.g., therapeutic administration, anaesthesia, insufflation du...
An underlay or overlay through which temperature-regulated air is circulated as part of an external circulating-air core temperature regulation system, intended to elevate and/or lower a patient’s core body temperature, typically in surgical and intensive c...
A stationary mains electricity (AC-powered) device designed to concentrate oxygen (O2) from ambient air and deliver the concentrated O2, typically through an attached nasal cannula, to a patient requiring oxygen therapy. It processes the air through an inte...
A mobile/portable mains electricity (AC-powered) device designed to concentrate oxygen (O2) from ambient air and deliver the concentrated O2, typically through an attached nasal cannula, to a patient requiring oxygen therapy. It processes the air through an...
A portable mains electricity (AC-powered) device designed to concentrate oxygen (O2) from ambient air and deliver the concentrated O2, typically through an attached nasal cannula, to a patient requiring oxygen therapy. It processes the air through an intern...
A mains electricity (AC-powered) device designed to deliver high-flow (typically greater than 15 L/min) heated and humidified ambient air or air/oxygen to a patient as therapy for a respiratory disorder [e.g., chronic obstructive pulmonary disease (COPD), b...
A device intended to measure and regulate the flow of a medical gas [e.g., oxygen (O2), carbon dioxide (CO2), nitrous oxide (N2O), helium/oxygen gas mixture (heliox), medical air] during various procedures (e.g., therapeutic administration, anaesthesia, ins...
A hand-held, battery-powered device assembly consisting of a graphical display unit and an attached probe or interchangeable probes, designed to noninvasively locate and assess the extent of vascular flow restriction (e.g., clots, stenosis, mechanical damag...
A mains electricity (AC-powered) device assembly consisting of a desktop unit, a graphical display unit and an attached probe or interchangeable probes, designed to noninvasively locate and assess the extent of vascular flow restriction (e.g., clots, stenos...
A device intended to measure and regulate the flow of a medical gas [e.g., oxygen (O2), carbon dioxide (CO2), nitrous oxide (N2O), helium/oxygen gas mixture (heliox), medical air] during various procedures (e.g., therapeutic administration, anaesthesia, ins...
A non-sterile underlay or overlay through which heated or cooled air is circulated to heat and alternatively cool a patient’s whole-body (i.e., elevate or lower core body temperature) typically in surgical and intensive care settings. Air temperature and fl...
An underlay or overlay through which heated or cooled air is circulated to heat and alternatively cool a patient’s whole body (i.e., elevate or lower core body temperature) typically in surgical and intensive care settings. Air temperature and flow are regu...
A sterile underlay or overlay through which heated or cooled air is circulated to heat and alternatively cool a patient’s whole-body (i.e., elevate or lower core body temperature) typically in surgical and intensive care settings. Air temperature and flow a...
A sterile underlay or overlay through which heated or cooled air is circulated to heat and alternatively cool a patient’s whole body (i.e., elevate or lower core body temperature) typically in surgical and intensive care settings. Air temperature and flow a...
An underlay or overlay through which heated or cooled air is circulated to heat and alternatively cool a patient’s whole-body (i.e., elevate or lower core body temperature) typically in surgical and intensive care settings. Air temperature and flow are regu...
A device designed to graphically record the instantaneous flow (velocity) of air at the mouth or, using an integrated signal, the volume of air per breath during inspiration or expiration. This recorder consists of a resistance attachment (e.g., wire screen...
A mains electricity (AC-powered) device that is typically a module or a component of a high-flow blood/fluid warmer, and that provides an alarm and/or stops the flow of fluid when it detects air or foam in the de-aeration chamber of the blood/fluid warming ...