482 GUDID devices
A connecting device designed as a mechanical coupling to join and lock together a distal tool to the surgical power tool to provide the power when these are incompatible and are of a different manufacture/industry standard. It is typically made from high-gr...
4 GUDID devices
A syringe transfer device or Luer-system adaptor intended to be used during patient blood collection to facilitate transfer of a clinical blood specimen from the blood access device (e.g., blood collection tube holder with needle) into a syringe that utiliz...
65 GUDID devices
A copy of a final shoulder reverse/standard adaptor prosthesis designed to be used before revision implant surgery to validate the appropriate size of the permanent prosthesis required by the patient, and to ensure its proper orientation and positioning. It...
12 GUDID devices
A non-sterile device intended to enhance the capture of exhaled end-tidal carbon dioxide (EtCO2) for evaluation of a patient's ventilatory, circulatory, or metabolic status, typically during the administration of anaesthesia. It is an adhesive, dome-like ad...
7 GUDID devices
A dedicated adaptor or transfer device intended to be used to facilitate the transfer of a blood specimen from a syringe into an evacuated blood collection tube. This device is intended to reduce the risk of needle stick injury or exposure to an uncontained...
5 GUDID devices
A connecting device designed to allow the attachment of an ophthalmic surgical instrument tip to an ophthalmic surgical instrument handle. It is typically in the form of a small, stainless steel, circular adaptor with a threaded interface that attaches to a...
3 GUDID devices
A sterile, plastic, scoop-like adaptor intended to be connected to a non-evacuated blood collection tube (e.g., it may pierce the tube stopper) to assist with the collection of blood droplets from the surface of skin during a capillary blood collection proc...
25,483 GUDID devices
A small, threaded, implantable rod with a screw head and drive intended for internal spinal fixation by being screwed into the spine to hold a correction/stabilization device (e.g., rod, plate, tether) to bone; it is made of a material that is not chemicall...
4,322 GUDID devices
A copy of a final femur prosthesis designed to be used during unicompartmental knee replacement surgery or total knee arthroplasty (TKA) to determine the correct alignment, size, and fit of the final prosthesis. It is one of a set, or a set, of graduated si...
2,629 GUDID devices
A copy of a final femur prosthesis designed to be used during unicompartmental knee replacement surgery or total knee arthroplasty (TKA) to determine the correct alignment, size, and fit of the final prosthesis. It is one of a set, or a set, of graduated si...
2,624 GUDID devices
A collection of various orthopaedic manual surgical instruments (e.g., screwdriver, trial rod, adaptor, mallet, guide tube, chisel, rasp, awl, burr, tap, drill) intended to be used to perform a bone-screw internal spinal fixation and/or spinal fusion cage i...
2,297 GUDID devices
An assembly of devices designed to conduct medical gases from the fresh gas supply outlet of an anaesthesia unit/workstation to the patient, typically connecting the patient, a ventilator/ventilation bag, carbon dioxide (CO2) absorber, and a monitor. It typ...
1,632 GUDID devices
An implantable artificial substitute for a diseased or injured femoral head that has an outer surface made of metal [e.g., cobalt-chrome (Co-Cr), titanium (Ti), stainless steel]. It is designed to be attached to the trunnion of a prosthetic femoral stem/sha...
1,415 GUDID devices
A collection of various orthopaedic manual surgical instruments (e.g., screwdriver, trial rod, adaptor, mallet, guide tube, chisel, rasp, awl, burr, tap, drill) intended to be used to perform a bone-screw internal spinal fixation and/or spinal fusion cage i...
1,176 GUDID devices
An insulated electrical cord designed with a mains electricity supply plug at one end and single or multiple outlet socket clusters at the other end, intended to enable a connection between a medical device and a mains electricity supply. It is typically us...
876 GUDID devices
A connecting device designed to join an implant to a surgical instrument or a surgical instrument to another instrument particularly to create an extension or to connect two devices where the interfaces of the devices are not compatible. It is typically mad...
873 GUDID devices
A sterile implantable artificial substitute for a diseased or injured femoral head that has an outer surface made of metal (e.g., titanium alloy). It is designed to be attached to the trunnion of a prosthetic femoral stem/shaft or a head/stem adaptor, and t...
755 GUDID devices
A sterile implantable artificial substitute for a diseased or injured femoral head that has an outer surface made of ceramic (e.g., alumina, zirconia). It is designed to be attached to the trunnion of a prosthetic femoral stem/shaft or a head/stem adaptor, ...
666 GUDID devices
A small connecting device designed to permit the connection of the devices that together deliver light to a work field from a light source. This device is used to connect together products of dissimilar manufacture and dimensions, e.g., a fibreoptic light c...
572 GUDID devices
An implantable artificial substitute for a diseased or injured femoral head that has an outer surface made of ceramic (e.g., alumina, zirconia). It is designed to be attached to the trunnion of a prosthetic femoral stem/shaft or a head/stem adaptor, and to ...
540 GUDID devices
A non-absorbent, non-powered, hand-held device in the form of a brush, a wire, strip of metal, or handle intended to clean the exterior and/or interior (lumen) of a surgical instrument (e.g., bur, reamer, bone tap, suturing device, sheath/shaft, ultrasonic ...
519 GUDID devices
A non-absorbent, non-powered, hand-held device in the form of a brush, a wire, strip of metal, or handle intended to clean the exterior and/or interior (lumen) of a surgical instrument (e.g., bur, reamer, bone tap, suturing device, sheath/shaft, ultrasonic ...
516 GUDID devices
A hand-held dental tool intended for the manual application of rotation to tighten/loosen/remove a device [e.g., dental implant, spatial register (localizer/tracker/calibrator)] fitted into or close to the oral cavity, and/or to a surgical instrument, in as...
515 GUDID devices
A device intended to be affixed to a patient's skull to enable precise localization of an area within the brain targeted for radiosurgical procedures (e.g., radiation treatment of a brain tumour). It is typically an assembly that includes a head ring or a h...
491 GUDID devices
An electro-optical device (e.g., a CCD) designed to be attached, either directly or with an adaptor, to a flexible or rigid endoscope to allow real-time viewing of the internal anatomy during an endoscopic surgical procedure and to obtain moving-picture doc...
454 GUDID devices
An electrically-powered one-piece device or modular device collection designed to accept an endpiece(s) [e.g., drill bit, saw blade] for drilling, cutting, polishing, and/or inserting procedures involving bones and tough tissues during a dental surgical pro...
450 GUDID devices
A non-absorbent, non-powered, hand-held device in the form of a brush, a wire, strip of metal, or handle intended to clean the exterior and/or interior (lumen) of a surgical instrument (e.g., bur, reamer, bone tap, suturing device, sheath/shaft, ultrasonic ...
449 GUDID devices
A manual device intended to be used for the administration of oral medication or delivery of enteral nutrition by connection to an enteral administration device. It consists of a calibrated hollow barrel (cylinder) and a moveable plunger intended to be oper...
444 GUDID devices
A connecting device designed to join an orthopaedic implant to a surgical instrument, or a surgical instrument to another instrument, typically to create an extension for removal of the implant (e.g., during a percutaneous interspinous distraction procedure...
404 GUDID devices
A hands-free, self-retaining frame intended to allow a dental professional to retract the lips/cheeks of a patient during an orthodontic or restorative dental procedure for easy access to the field of operation. It is designed to be placed in and around the...