A flexible tube intended to be used for ureteral access to allow introduction of other instruments (e.g., endoscope, catheter) and/or for guidewire exchange during a urological procedure. It may be intended for ureteral access via transurethral and/or percu...
A collection of sterile devices designed to aspirate and contain a sample of amniotic fluid from the amniotic sac, via a transabdominal approach, for analysis. Components typically include a needle with stylet and syringe, specimen containers/medium, drapes...
An assembly of devices designed to continuously obtain, amplify, and record various signals generated during procedures usually performed in the cardiac catheterization laboratory. It typically consists of a computerized central workstation including a moni...
A sterile woven/knitted or porous material made of non-bioabsorbable synthetic polymer (e.g., polypropylene) intended to be permanently implanted (via transobturator, transvaginal, retropubic or suprapubic approach) to support the urethra for the treatment ...
A collection of sterile devices designed to aspirate and contain a sample of amniotic fluid from the amniotic sac, via a transabdominal approach, for analysis. Components typically include a needle with stylet and syringe, specimen containers/medium, drapes...
A flexible tube intended to be used for ureteral access for the passage of other instruments (e.g., endoscope, catheter) and/or for guidewire exchange during a urological procedure. It may be intended for ureteral access via transurethral and/or percutaneou...
A sterile, implantable flexible wire with an electrode, insulated with non-conductive material except at its ends, which serves as an electrical conductor to transmit pacing impulses from an implanted cardiac resynchronization therapy (CRT) pulse generator ...
A woven/knitted or porous strip of material made of non-bioabsorbable synthetic polymer (e.g., polypropylene) intended to be permanently implanted (via transobturator, transvaginal, retropubic or suprapubic approach) to support the urethra for the treatment...
An implantable flexible wire with an electrode, insulated with non-conductive material except at its ends, which serves as an electrical conductor to transmit pacing impulses from an implanted cardiac resynchronization therapy (CRT) pulse generator to the l...
An assembly of devices intended to be used for the thermal ablation of targeted prostate tissue using water vapour via a transurethral approach under ultrasound guidance. It includes: 1) a water vapour ablation generator/control unit; 2) an invasive water v...
A hand-held manual surgical instrument with a sharp pyramidal or conical point intended to be used to create a percutaneous puncture using the transobturator approach (i.e., insertion points overlie the obturator space and the obturator foramen membrane is ...
An implantable device intended to treat a prolapsed lumbar intervertebral disc by repairing the defect in the annulus fibrosus for the prevention of recurrent herniation of the nucleus pulposus. It consists of a mesh plug used to replace the disrupted segme...
A sterile woven/knitted or porous material made of non-bioabsorbable synthetic polymer (e.g., polypropylene) intended to be permanently implanted (typically via transobturator approach) to support the urethra for the treatment of male stress urinary inconti...
An assembly of devices used to produce 2-dimensional cross-sectional (tomographic) images on x-ray film at a fixed angle and depth in relation to body position by coordinating a prescribed pattern of non-linear x-ray tube motion (elliptical, circular, clove...
A sterile, flexible, probe-like device intended to be connected to a cardiac laser system for the delivery of laser energy directly onto the heart during transmyocardial revascularization surgery (open surgical approach). It includes fibreoptic materials wh...
An electrically-powered, noninvasive unit designed to: 1) generate electrical energy in the radio-frequency (RF) band, for the focal RF ablation of soft tissues (e.g., uterine fibroids) via laparoscopic approach; 2) track the location of an electrosurgical ...
A collection of sterile devices intended to be used to obtain a tissue specimen from within the biliary duct system for histological analysis by a percutaneous approach, typically under fluoroscopic visualization. It typically includes flexible biopsy force...
A collection of devices and materials designed to aspirate and contain a sample of amniotic fluid from the amniotic sac, via a transabdominal approach, for analysis. Components typically include a needle with stylet and syringe, specimen containers/medium, ...
An invasive, hand-held, thin instrument (probe) with a distal electrode intended for preoperative and/or intraoperative delivery of electrical stimulation to the cochlear (auditory) nerve to assess nerve function prior to implantation of a cochlear implant ...
A mains electricity (AC-powered) device assembly in which input energy (e.g., flashlamp, diode laser) is used to excite a glass/crystal rod [typically yttrium-aluminium-garnet doped with holmium (Ho:YAG)] to emit a high-power laser beam intended for transmy...