1 GUDID devices
A surgical device intended to be used as a platform onto which a donor cornea is placed to allow a precise circular section of the cornea (corneal button) to be cut from the cornea for subsequent transplantation into a prepared patient. It is a small base p...
27 GUDID devices
A non-sterile plate, typically with a waist belt for attachment, intended to be placed over an enteric stoma (surgically-created artificial opening between the intestines and the body surface through which bodily waste is drained) to protect it from harmful...
9 GUDID devices
A non-sterile plate, typically with a waist belt for attachment, intended to be placed over an enteric stoma (surgically-created artificial opening between the intestines and the body surface through which bodily waste is drained) to protect it from harmful...
1 GUDID devices
A plate-like device designed to function as a sturdy support (base) for a self-expanding cardiac valve prosthesis collapsing tool during the procedure where the tool is used to reduce the diameter of a self-expanding cardiac valve prosthesis to facilitate i...
12 GUDID devices
A small, cylindrical container intended to temporarily store venous blood and subsequently placed in a centrifuge to produce platelet rich fibrin (PRF) or platelet rich plasma (PRP) for application to the patient from whom the blood was taken (typically for...
345 GUDID devices
A collection of surgical instruments intended to cut a precise circular section of the cornea (corneal button) from stored cadaveric donor tissue for transplantation into a prepared patient. It typically consists of a small base plate, an extremely sharp an...
292 GUDID devices
A plastic pouch designed to be attached around a faecal stoma for use as a receptacle for faeces following a colostomy [the stool (faeces) being generally well formed]. It consists of two or more separate parts including the pouch with a flange and a base p...
10 GUDID devices
A plastic pouch designed to be attached around a stoma for use as a receptacle for intestinal output following a colostomy or ileostomy (effluent is typically of a fluid consistency). It consists of two or more separate parts including the pouch with a flan...
9 GUDID devices
A collection of non-sterile devices intended to be used for attachment/replacement of a urostomy bag (for collecting urine following a urostomy procedure). It includes the urostomy bag, a base plate, and additional devices (e.g., towels, wipes, scissors) to...
3 GUDID devices
A sterile device intended for the circumferential resection of tissue to treat simple anal fistula. It includes a probe for initial exploration of the fistula, a guide with attachable base plate, and cylindrical cutting tool; the cutting tool is intended to...
3 GUDID devices
An implantable device designed to augment the implantation of a shoulder prosthesis base plate (glenoid base plate) by serving as a space-filler within the prosthesis, typically to replace lost bone and increase bone contact area and aid stability. It is ty...
2 GUDID devices
A non-sterile absorbent device intended to be fitted around the connection between an ostomy base plate and an ostomy bag, to absorb any sweat or bodily fluid/waste associated with a leak between the base plate and the skin, to prevent its spread, absorptio...
1 GUDID devices
A standard, non-motorized, diagnostic x-ray beam-limiting device that has a fixed size opening. It attaches by means of a slot or base plate to a diagnostic x-ray system tube housing and is used to limit the effects of scattered radiation on image quality a...
1 GUDID devices
A collection of non-sterile devices intended to be used for attachment/replacement of a urostomy bag (for collecting urine following a urostomy procedure). It includes the urostomy bag, a base plate, and additional devices (e.g., towels, wipes, scissors) to...
232 GUDID devices
A sterile component of a reverse shoulder prosthesis that consists of a metal plate [e.g., titanium (Ti), cobalt-chrome (Co-Cr), stainless steel] intended to be firmly attached to the scapula with screws. It is intended to serve as the foundation for the re...
86 GUDID devices
A device in the form of a flat plate/bar intended to be attached to an operating/radiological table to function as a supportive foundation to which patient positioning devices can be attached (e.g., arch frame, thermoplastic mask, headrest, head positioner)...
39 GUDID devices
A non-sterile device designed to hold test tubes in an upright and secured position. It is typically made of metal and/or plastic and consists of a base plate upon which it stands and second plate containing a mesh (grid of square slots) or round holes whic...
38 GUDID devices
A device in the form of a non-mirrored flat plate/bar intended to be attached to an operating/radiological table to function as a supportive foundation to which patient positioning devices (not included) can be attached [e.g., arch frame, thermoplastic mask...
1 GUDID devices
A plate with multiple wells, a selectively permeable microfilter membrane and an optically clear base, intended to be used for microfiltration and capture of target molecules (e.g., DNA oligonucleotides) for subsequent analysis and/or imaging during an in v...
1 GUDID devices
A plate-like device intended to be placed on the floor and fixed to a stand-on floor scale to function as a foundation for the attachment of other independent devices, such as a patient-height measure rod or a patient hand rail/standing frame. This is a reu...
205 GUDID devices
A foundation on which an occlusal rim is built or a trial denture set-up. Dental base plates are made of wax, shellac or polymers and formed individually for one patient (custom-made). This is a single-use device.
10 GUDID devices
A computerized device assembly designed for: 1) analysis of biomechanical/neuromuscular function using dedicated hardware; and 2) neuromuscular rehabilitation therapy at multiple anatomical sites based on patient interaction with dedicated physical-response...
9 GUDID devices
A plate-like device intended to function as a sturdy support (base) for the holder/implantation tool of a cardiovascular implant (e.g., biologic-polymer aorta graft, heart valve bioprosthesis). It may be made of plastic and/or metallic material and includes...
12,334 GUDID devices
A copy of a final tibia prosthesis designed to be used during unicompartmental knee replacement surgery or total knee arthroplasty (TKA) to determine the correct alignment, size, and fit of the final prosthesis. It is one of a set, or a set, of graduated si...
8,142 GUDID devices
A copy of a final tibia prosthesis designed to be used during unicompartmental knee replacement surgery or total knee arthroplasty (TKA) to determine the correct alignment, size, and fit of the final prosthesis. It is one of a set, or a set, of graduated si...
1,748 GUDID devices
A hand-held manual surgical instrument designed for the surgical insertion and/or extraction of a non-tissue based (inorganic) orthopaedic implant (e.g., a bone nail, spiral blade, or bone fixation plate). It is an instrument in a one-piece or modular confi...
726 GUDID devices
An assembly of implantable devices designed to treat fractures of the hip. It typically includes a metal plate that is held in position with fasteners such as screws and nails, or bolts, nuts and washers. The assembly is typically intended to treat stable o...
697 GUDID devices
A non-sterile device designed with a flat surface intended to be applied and adhered to peristomal skin (typically of a normal, well-formed stoma) to facilitate the correct positioning and anchorage of the flange of an intestinal ostomy bag (i.e., one-piece...
586 GUDID devices
A noninvasive device designed to fix a percutaneous (excluding intracranial) catheter, tube, and/or drain (e.g., IV, epidural, or drainage catheter, GI tube) to a patient's body; it may additionally be intended for holding a non-surgically-invasive tube (e....
522 GUDID devices
A plastic pouch designed to be attached around a stoma for use as a receptacle for intestinal output following a colostomy or ileostomy (effluent is typically of a fluid consistency). It consists of two or more separate parts including the pouch with a flan...