A sterile device(s) used in conjunction with a conduction blood/fluid warmer to heat banked blood, blood products, and intravenous (IV) fluids to a temperature appropriate for infusion into a patient. It typically consists of a pouch(es) or a flexible casse...
A collection of devices used in conjunction with a conduction blood/fluid warmer to heat banked blood, blood products, and intravenous (IV) fluids to a temperature appropriate for infusion into a patient. It consists of a pouch(es) or a flexible cassette th...
A collection of devices used in conjunction with a convection blood/fluid warmer to heat banked blood, blood products, and intravenous (IV) fluids to a temperature appropriate for infusion into a patient. It may consist of coiled tubing, or other design, th...
A sterile device(s) used in conjunction with a convection blood/fluid warmer to heat banked blood, blood products, and intravenous (IV) fluids to a temperature appropriate for infusion into a patient. It may consist of coiled tubing, or other design, throug...
A collection of devices used in conjunction with a radiation blood/fluid warmer to heat banked blood, blood products, and intravenous (IV) fluids to a temperature appropriate for infusion into a patient. It typically consists of a pouch(es) or a flexible ca...
A sterile collection of disposable devices used in conjunction with a cryosurgical unit as well as monitoring and other devices to perform a surgical technique that involves freezing a targeted area of tissue to damage and destroy cancer cells in the unwant...
An electrically-powered device designed for in-line heating of banked blood, blood products, intravenous (IV) solutions, and irrigation fluids, typically from about 4ºC to near body temperature (i.e., 35 to 37ºC) before infusion, through the convection of h...
A mains electricity (AC-powered) device designed for in-line heating of banked blood, blood products, intravenous (IV) solutions, and irrigation fluids, typically from about 4?C to near body temperature (i.e., 35 to 37?C) before infusion, through the convec...
A mains electricity (AC-powered) device that is typically a module or a component of a high-flow blood/fluid warmer, and that provides an alarm and/or stops the flow of fluid when it detects air or foam in the de-aeration chamber of the blood/fluid warming ...
An electrically-powered device designed for in-line heating of banked blood, blood products, intravenous (IV) solutions, and irrigation fluids, typically from about 4ºC to near body temperature (i.e., 35 to 37ºC) before infusion, through the application of ...
A temperature sensing device intended to be placed into a body orifice or on the body surface and used in conjunction with a separate parent device with a display (e.g., electronic patient thermometer, infant warmer) to enable measurement/monitoring of a pa...
A temperature sensing device intended to be placed into a body orifice or on the body surface, and used in conjunction with a separate parent device with a display (e.g., electronic patient thermometer, infant warmer) to enable measurement/monitoring of a p...
A mains electricity (AC-powered) device, which may include rechargeable batteries, designed for in-line heating of banked blood, blood products, intravenous (IV) solutions, and irrigation fluids, typically from about 4ºC to near body temperature (i.e., 35 t...
A collection of sterile devices intended to support and provide continuous physiologic organ perfusion to a donated kidney(s) during its preservation, evaluation, and transport in a kidney donor-organ preservation/transport system from the donor to the rece...
An electrically-powered device designed for in-line heating of banked blood, blood products, intravenous (IV) solutions, and irrigation fluids, typically from about 4ºC to near body temperature (i.e., 35 to 37ºC) before infusion, through the conduction of h...
A mains electricity (AC-powered) mobile device that contains an infrared (IR) heating element(s) designed to emit controlled, evenly distributed overhead heat to the body of a newborn/infant patient requiring supplemental heat. This device is equipped with ...
An electrically-powered heating device intended to warm patient-contact instruments (e.g., rigid endoscopes or trocars) before they are introduced into body orifices or other parts of the body. It typically consists of a tabletop device that has recesses or...
A portable, mains electricity (AC-powered) device intended to be used to prewarm gels (e.g., ultrasonic coupling gels, vaginal exploratory gels) prior to patient application. It is typically a tabletop device that includes a recess or a well for placement o...
A mains electricity (AC-powered) heating device into which tubes containing anaesthetic solutions are placed intended to warm the solution prior to it being administered to a patient for anaesthesia. It typically consists of a tabletop device that has wells...
A sterile heating device intended to warm patient-contact instruments (e.g., rigid endoscopes or trocars) before they are introduced into body orifices or other parts of the body. It typically consists of an envelope that is wrapped around the instrument (e...
A mains electricity (AC-powered) device designed for in-line heating of rapidly-infused (may exceed 1 L/min) banked blood, blood products, and intravenous (IV) solutions (crystalloid and colloid), typically from about 4?C to near body temperature (i.e., 35 ...
A mains electricity (AC-powered) heating device into which a bottle is intended to be placed for the preheating of its contents (e.g., milk for feeding infants, water, or other fluids). It typically consists of a tabletop device that has a well(s) for place...
An electrically-powered device designed for in-line heating of rapidly-infused (may exceed 1 L/min) banked blood, blood products, and intravenous (IV) solutions (crystalloid and colloid), typically from about 4ºC to near body temperature (i.e., 35 to 37ºC),...
A fixed (non-adjustable) device designed with a mattress or cushions containing air, water, gel, or other appropriate material used for the continuous care of newborns, and sick and/or premature babies. It has a size to suit such patients and provide enviro...
A collection of sterile devices intended to support and provide continuous physiologic organ perfusion to a donated liver during its preservation, evaluation, and transport in a liver donor-organ preservation/transport system from the donor to the receiver ...
A mains electricity (AC-powered) device designed to heat factory-sealed prep pads (skin cleansing pads typically containing alcohol or povidone iodine), with a pre-set maximum temperature (e.g., 55?C) for the purpose of warming the pads prior to use on a pa...
A small electrically-powered convection heater intended to be mounted on the armrest or tray of a wheelchair to warm the air around the hands of the wheelchair occupant. It may be powered by a connection to a powered wheelchair and may be supplied with a co...
A collection of sterile devices intended to support and provide continuous physiologic organ perfusion to a donated heart during its preservation, evaluation, and transport in a heart donor-organ preservation/transport system from the donor to the receiver ...
A collection of sterile devices intended to support and provide continuous physiologic organ perfusion to a donated lung(s) during its preservation, evaluation, and transport in a lung donor-organ preservation/transport system from the donor to the receiver...
A device designed to apply heat, by direct contact or from a radiant source, to the surface of the perineum (the area between the vulva and the anus). It is intended to help to soothe the perineum after an episiotomy (a surgical incision into the perineum a...