Search

65 matching records for CONTOUR.

NDC#

DailyMed#

Propel

Intersect ENT, INC.

20241231

GMDN Terms#

Radio-frequency skin contouring system applicator tip

66 GUDID devices

A removable endpiece that is attached to a radio-frequency (RF) skin contouring system applicator (handpiece), used to regulate the delivery of RF energy to the patient during treatment. As a procedural safety measure, the device may permit the transfer of ...

Cryolipolysis body contouring system program card

56 GUDID devices

A portable electronic device designed to connect to the data port of a cryolipolysis body contouring system to provide its control unit with a selected treatment profile. It contains data such as cooling intensity factor (CIF), cycle time and other relevant...

Cryolipolysis body contouring system applicator

35 GUDID devices

A component of a cryolipolysis body contouring system designed to convey controlled cold from the system's control unit to the skin and subcutaneous tissues for cold-assisted lipolysis (coolsculpting). It is typically in the form of an articulated arm desig...

Radio-frequency skin contouring system applicator, monopolar

23 GUDID devices

A monopolar handpiece that is part of a skin contouring system that uses radio-frequency (RF) energy to provide a capacitively coupled electrical connection for the transfer of radiated energy through a patient's skin in deep heat-mediated skin modification...

Radio-frequency skin contouring system applicator, bipolar

20 GUDID devices

A bipolar handpiece that is part of a skin contouring system that uses radio-frequency (RF) energy to provide a capacitively coupled electrical connection for the transfer of radiated energy through a patient's skin in deep heat-mediated skin modification. ...

Mechanical skin contouring system injection/transection set

14 GUDID devices

A collection of sterile components of a mechanical skin contouring system intended to temporarily minimize the manifestation of cellulite by transection of the cellulite-tethering fibrous tissue by motorized mechanical means. It consists of template plates,...

Cryolipolysis body contouring system control unit

7 GUDID devices

A mains electricity (AC-powered) component of a cryolipolysis body contouring system designed to allow the operator to adjust and control the operating functions of the system during cold-assisted lipolysis treatment (coolsculpting) to regulate the cooling ...

Mechanical skin contouring system motor

5 GUDID devices

A non-sterile, mains electricity (AC-powered) motor component of a mechanical skin contouring system intended to temporarily minimize the manifestation of cellulite by transection of the cellulite-tethering fibrous tissue by motorized mechanical means. It i...

Cryolipolysis body contouring system gel pad

4 GUDID devices

A non-sterile component of a cryolipolysis body contouring system designed to be applied to the skin of a patient to convey cold energy at the interface between the system’s applicator and the treatment site on the patient during cold-assisted lipolysis tre...

Cryolipolysis body contouring system applicator liner

2 GUDID devices

A non-sterile cover designed to provide a hygienic barrier between the contact surface of a cryolipolysis body contouring system applicator and a dedicated gel pad placed on the surface of a patient's skin during cold-assisted lipolysis treatment (coolsculp...

Radio-frequency skin contouring system electrode, return

2 GUDID devices

A non-active conductor that is part of a skin contouring system that uses radio-frequency (RF) energy and that is placed on a patient's skin to provide a complete electrical circuit for energy transferred to the patient from a monopolar applicator. This dev...

Resective skin contouring/liposuction system depth guide

2 GUDID devices

A sterile component of a resective skin contouring/liposuction system intended to connect the system handpiece to a single coring needle to function as a guide for the insertion depth of the needle. It is one of a set, or a set, of graduated sizes and provi...

Multi-modality skin contouring system applicator, infrared light

1 GUDID devices

A device that is part of a skin contouring system that is used to apply an energy consisting of infrared light to the skin of a patient to temporarily minimize the manifestation of cellulite, loose or wrinkled skin. This device is connected to an energy-pro...

Orthodontic metal band

33,449 GUDID devices

A thin metal ring designed to be fitted around the contours of a tooth and cemented into place to support an orthodontic attachment (e.g., bracket, tube), brazed or soldered onto the ring, intended to be secured to the tooth. This is a single-patient device...

Tibial insert

16,906 GUDID devices

An implantable device designed to articulate the femoral and tibial components of a knee joint prosthesis during primary or revision bicondylar knee joint replacement. It is typically a one-piece contoured polyethylene (PE) insert, or a more complex device ...

Custom-made orthopaedic/craniofacial surgical guide

4,418 GUDID devices

A custom-made surgical instrument intended to be used in an orthopaedic and/or craniomaxillofacial procedure (e.g., osteotomy, arthroplasty, tumour resection, distraction osteogenesis, cranial vault reconstruction) to assist in the intraoperative orientatio...

Press-fit femoral stem prosthesis

2,829 GUDID devices

A sterile implantable device designed to replace the proximal femoral neck as part of a total hip arthroplasty (THA). The device is contoured to enable fixation by pressing the distal end into the cortex of the remaining natural femur to achieve a mechanica...

Medullary canal orthopaedic reamer, rigid

2,623 GUDID devices

An orthopaedic surgical instrument designed to open and enlarge the medullary canal (e.g., in the femur, tibia, ulnar) for the insertion of various devices during prosthesis implantation or fracture fixation procedures. It is typically designed as a long, c...

Preformed complete denture

2,294 GUDID devices

A prefabricated plastic plate designed to fit over an edentulous maxillary or mandibular alveolar ridge; an entire complement of artificial teeth from one arch is added to create a full denture. It is available in several standard sizes that can be contoure...

Eyelid speculum, reusable

1,840 GUDID devices

A self-retaining, ophthalmic surgical instrument intended to be used to retract the eyelids during an opthalmologic examination or procedure. It is typically composed of two arms joined at a pivot point and that terminate in blunt tips; the arms can be expa...

Nasal speculum, reusable

1,303 GUDID devices

A hand-held surgical instrument inserted into a nostril and manually expanded to maximally open the nostril by stretching the tissue around the nasal orifice, allowing access for examination or ear/nose/throat (ENT) surgical intervention. The device is made...

Polyethylene craniofacial tissue reconstructive material

1,066 GUDID devices

A sterile implantable device intended to support, contour, and provide structure for the craniofacial anatomy (i.e., head and face including the chin, cheeks, nose, eye sockets and ears) during reconstructive and plastic surgery procedures. It is typically ...

Unicondylar knee insert

993 GUDID devices

A sterile implantable device designed to articulate the femoral and tibial components of a knee joint prosthesis during primary or revision unicompartmental knee joint replacement. It is a one-piece contoured device typically made of polyethylene (PE).

Medullary canal orthopaedic reamer, flexible

943 GUDID devices

An orthopaedic surgical instrument designed to open and enlarge the medullary canal (e.g., in the femur, tibia, ulnar) for the insertion of various devices during prosthesis implantation or fracture fixation procedures. It is typically designed as a long cy...

Press-fit hip femur prosthesis, modular

912 GUDID devices

A sterile implantable principal component of a total hip prosthesis (femoral component) designed to replace the femoral head and neck. The device is composed of two or more separate pieces (e.g., head, neck, and stem) designed to be joined, and is contoured...

Press-fit hip femur prosthesis, one-piece

789 GUDID devices

A sterile implantable principal component of a total hip prosthesis (femoral component) designed to replace the femoral head and neck. The device is one-piece and is contoured to enable fixation by pressing the distal end into the cortex of the remaining na...

Universal operating table top

485 GUDID devices

A component of a modular operating table designed as a detachable table top that can be adjusted to support a patient during many types of surgical interventions. It may consists of many articulated sections that can be elevated or lowered for contouring to...

Custom-made orthopaedic surgical guide, non-sterile

475 GUDID devices

A non-sterile, custom-made surgical instrument intended to be used in an orthopaedic and/or craniomaxillofacial procedure (e.g., osteotomy, arthroplasty, tumour resection, distraction osteogenesis, cranial vault reconstruction) to assist in the intraoperati...

Custom-made organ/bone anatomy model/surgical guide kit

431 GUDID devices

A collection of custom-made devices intended to be used to assist anatomical visualization, surgical treatment planning, and intraoperative surgical procedures (e.g., orientation of implant components, guiding of surgical instruments). It consists of an ana...

Rectal speculum

426 GUDID devices

A hand-held manual surgical instrument intended to be used to expand or stretch the rectal orifice/canal after it is inserted and opened. It is comprised of two arms joined at a pivot point and is available in various sizes, shapes, and contours; it is usua...