An implantable device intended to divert excessive cerebrospinal fluid (CSF) from the brain ventricles to either the peritoneal cavity or the heart right atrium (i.e., dual-capability), where it can be absorbed into the body, as a treatment for increased in...
A sterile implantable component of a lumboperitoneal shunt designed to regulate the pressure and flow of cerebrospinal fluid (CSF) from the subarachnoid space of the lumbar spine to the peritoneal cavity in the management of raised CSF pressure (e.g., cause...
A sterile implantable device intended to divert excessive cerebrospinal fluid (CSF) from the subarachnoid space of the lumbar spine to the peritoneal cavity, where it can be absorbed into the body, as a treatment for elevated intracranial pressure due to in...
An implantable component of a lumboperitoneal, ventriculoperitoneal or ventriculoatrial shunt designed to be connected to a lumbar, ventricular and/or peritoneal catheter (not included) to permit hypodermic infusion/injection of materials (e.g., chemotherap...
An implantable device intended to divert excessive cerebrospinal fluid (CSF) from the subarachnoid space of the lumbar spine to the peritoneal cavity where it can be absorbed into the body, as a treatment for raised CSF pressure (e.g., caused by hydrocephal...
An implantable device intended to function as part of a lumboperitoneal, ventriculoperitoneal or ventriculoatrial shunt to regulate the pressure and flow level of cerebrospinal fluid (CSF) from the lumbar spine or brain to the peritoneum/heart right atrium ...
A sterile, flexible tube intended to be surgically inserted through the skull for long-term (> 30 days) subdural access to the brain (e.g., cerebral ventricles, cystic tumours) for cerebrospinal fluid (CSF) drainage and/or infusion of materials (e.g., chemo...
A sterile, implantable chamber intended to be connected to an intracerebral catheter for infusion/injection of materials (e.g., chemotherapeutic agents, radioisotopes) into the brain (e.g., cerebral ventricles, cystic tumours, tumour cavities); it may also ...
A flexible tube with a sensor at the distal end intended to be surgically inserted through the skull for short-term (= 30 days) access to the ventricular and/or parenchymal areas of the brain to measure intracranial parameters [e.g., intracranial pressure (...
A sterile flexible tube intended to be surgically inserted through the skull for short-term (= 30 days) subdural access to the brain (e.g., cerebral ventricles, cystic tumours) for cerebrospinal fluid (CSF) drainage and/or infusion of materials (e.g., chemo...
A flexible tube intended to be surgically inserted through the skull for short-term (= 30 days) subdural access to the brain (e.g., cerebral ventricles, cystic tumours) for cerebrospinal fluid (CSF) drainage and/or infusion of materials (e.g., chemotherapeu...
A sterile flexible tube with a sensor at the distal end intended to be surgically inserted through the skull for short-term (= 30 days) access to the ventricular and/or parenchymal areas of the brain to drain cerebrospinal fluid (CSF) and to measure intracr...
A flexible tube with a sensor at the distal end intended to be surgically inserted through the skull for short-term (= 30 days) access to the ventricular and/or parenchymal areas of the brain to measure intracranial parameters [e.g., intracranial pressure (...
A screening receptacle intended to concentrate a fluid clinical specimen [e.g., serum, urine, cerebrospinal fluid (CSF)] by filtration prior to in vitro diagnostic investigation. It is in the form of a container (e.g., tube, multi-well reservoir) with a sem...