212 GUDID devices
A collection of sterile devices intended to be fitted to multiple endoscope working channels/ports to enable an endoscope operator control the function of the working channels/ports and prevent retrograde flow of fluids, gases, and other materials. It typic...
13 GUDID devices
A mains electricity (AC-powered) instrument designed to test a flexible endoscope for leaks from its internal channels. It is connected to the endoscope using tubing with appropriate connectors to irrigate the channels of the endoscope with air and/or water...
12 GUDID devices
A hand-operated device used to test a flexible endoscope for leaks from its internal channels. It is connected to the endoscope using tubing with connectors to subject the channels to a build-up of air pressure that is created with a hand pump (a bulb). Its...
12,599 GUDID devices
A shaft of metal intended to be used in dental surgery to create channels of appropriate depth and diameter in bone (osteotomy) of the oral cavity to facilitate the implantation of a dental fixture/appliance. The device is typically available in a set of gr...
2,495 GUDID devices
A component of a rigid or flexible endoscope assembly designed as a tube through which an endoscope (e.g., hysteroscope) and endoscopic elements are introduced and assembled to create a complete operative endoscopic unit; it is also designed to function as ...
1,194 GUDID devices
A hand-held, sterile surgical instrument used to scrape and score the cancellous vertebral bone of the spine, typically during a percutanous, minimally-invasive procedure. It consists of a long, thin, metal shaft that terminates distally in a mushroom-like ...
703 GUDID devices
A sterile shaft of metal intended to be used in dental surgery to create channels of appropriate depth and diameter in bone (osteotomy) of the oral cavity to facilitate the implantation of a dental fixture/appliance. The device is typically available in a s...
596 GUDID devices
A sterile implantable device intended to divert excessive cerebrospinal fluid (CSF) from the ventricles (fluid-filled cavities) of the brain to the peritoneal cavity, where it can be absorbed into the body. It typically consists of three main parts: 1) a ve...
566 GUDID devices
A shaft of metal intended to be used in dental surgery to create channels of appropriate depth and diameter in bone (osteotomy) of the oral cavity to facilitate the implantation of a dental fixture/appliance. The device is typically available in a set of gr...
559 GUDID devices
A hand-held manual surgical instrument intended to be used to scrape and debride tissue from a bone surface (e.g., cancellous vertebral bone of the spine) or a cavity wall during a neurosurgical procedure. It consists of a long, thin, metal shaft that termi...
510 GUDID devices
A sterile implantable device intended to divert excessive cerebrospinal fluid (CSF) from the ventricles (fluid-filled cavities) of the brain to either the peritoneal cavity or the right atrium (i.e., dual-capability) where it can be absorbed into the body. ...
443 GUDID devices
A hand-held manual surgical instrument intended to be used to scrape and debride tissue from a bone surface (e.g., cancellous vertebral bone of the spine) or a cavity wall during a neurosurgical procedure. It consists of a long, thin, metal shaft that termi...
389 GUDID devices
A non-sterile device designed for mixing inactive compounds during a dental procedure to produce a functional dental restorative/impression material which may be applied directly to the oral cavity/teeth of the patient or used for some other dental applicat...
328 GUDID devices
An implantable device intended to divert excessive cerebrospinal fluid (CSF) from the brain ventricles to either the peritoneal cavity or the heart right atrium (i.e., dual-capability), where it can be absorbed into the body, as a treatment for increased in...
222 GUDID devices
A collection of devices, or a preassembled device, intended to allow connection between the appropriate port(s) of a sterilizer/disinfector and the channels, ports or distal end of an endoscope or endoscopic device (e.g., ultrasound transducer) during devic...
192 GUDID devices
A component of a rigid or flexible endoscope assembly designed as a tube through which an endoscope (e.g., hysteroscope) and endoscopic elements are introduced and assembled to create a complete operative endoscopic unit; it is also designed to function as ...
144 GUDID devices
A device designed for mixing inactive compounds during a dental procedure to produce a functional dental restorative/impression material which may be applied directly to the oral cavity/teeth of the patient or used for some other dental application. It is n...
105 GUDID devices
A sterile device intended to be used for the in situ removal of fog/blood/debris from the lens of an endoscope (e.g., laparoscope), by directing gas and/or liquid to the edge of the lens. It is typically a multichannel sleeve with connection tubing. Gases/f...
105 GUDID devices
An endoscope with a flexible inserted portion intended for endoscopic procedures of the airways and tracheobronchial tree (i.e., bronchoscopy). It typically consists of a handle portion and an insertion tube which includes working channels and a distal came...
72 GUDID devices
A steerable wire with a filter at its distal end intended to be used to facilitate the placement of diagnostic/interventional vascular devices (e.g., angioplasty balloons, intravascular stents) in the lumen of a blood vessel (coronary, carotid, peripheral),...
66 GUDID devices
A sterile endoscope with a flexible inserted portion intended for endoscopic procedures of the airways and tracheobronchial tree (i.e., bronchoscopy). It typically consists of a handle portion and an insertion tube which includes working channels and a dist...
61 GUDID devices
A device used for the automatic internal cleaning, lubrication and maintenance of dental handpieces used in dentistry (e.g., pneumatically or electrically driven scalers, motors, or turbines). This device will automatically run programs for, e.g., the clean...
61 GUDID devices
An assembly of mains electricity (AC-powered) devices intended to reduce scalp hair loss associated with intravenous chemotherapy treatment by cooling the scalp to cause vasoconstriction and reduction of chemotherapy drug uptake by the follicular cells. It ...
59 GUDID devices
A foot-worn device designed to space the toes of the foot to relieve pain, pressure/friction between toes, and/or to facilitate realignment of the toes to a natural position. It is made of soft materials (e.g., silicone, polymer gel) and may be available in...
58 GUDID devices
A sterile surgical device intended to be inserted across a surgical incision to separate the margins of the incision to create a conduit to the underlying organs/tissues during hand-assisted minimally-invasive and open surgery. It consists of an external an...
47 GUDID devices
A sterile device intended to be connected to a drive unit (not included) to circulate blood through the extracorporeal circuit of a non-roller type cardiopulmonary bypass system, via a centrifugal force mechanism, for gas exchange and reinfusion. It include...
32 GUDID devices
An electrically-powered device intended to test an invasive medical device (e.g., flexible endoscope, ultrasound transducer) for leaks of air and/or fluid from its internal channels and/or housing by introducing air at increased pressures. It typically inco...
25 GUDID devices
A device intended to be connected to a drive unit (not included) to circulate blood through the extracorporeal circuit of a non-roller type cardiopulmonary bypass system, via a centrifugal force mechanism, for gas exchange and reinfusion; it may in addition...
25 GUDID devices
A mains electricity (AC-powered) laboratory instrument intended to be used for the qualitative and/or quantitative in vitro determination of multiple clinical chemistry analytes in a clinical specimen. Analytes detected may include electrolytes, specific pr...
22 GUDID devices
A device designed specifically for use in diagnostic nuclear medicine imaging applications operating with an energy range of less than 500 kilo-electronvolt (keV). It consists of an array of small openings drilled or cast into a flat sheet or plate of lead ...