A collection of non-sterile devices intended to be integrated within a breathing circuit to enable interface of gases between the breathing circuit and a respiratory monitoring device for sampling the patient's expired gas for measurements of pressure, flow...
A flexible container intended to be used for the collection of waste fluids during preparation and processing of an extracorporeal circuit (e.g., autotransfusion, haemodialysis, haemofiltration, apheresis, adsorption treatment), including the collection and...
A sterile flexible container intended to be used for the collection of waste fluids during preparation and processing of an extracorporeal circuit (e.g., haemodialysis, haemofiltration, apheresis, adsorption treatment), including the collection and rinsing ...
"A connecting device shaped in the form of a ""Y"" or ""T"" and designed to connect compatible components [e.g., the tubing and face mask or an endotracheal (ET) tube] to create a breathing circuit. In order to function this device will be part of a breathi...
A connecting device shaped in the form of a "Y" and designed to connect compatible components [e.g., the tubing and face mask or an endotracheal (ET) tube] to create a breathing circuit. In order to function this device will be part of a breathing circuit a...
A connecting device shaped in the form of a "Y" and designed to connect compatible components [e.g., the tubing and face mask or an endotracheal (ET) tube] to create a breathing circuit. In order to function this device will be part of a breathing circuit a...
"A connecting device shaped in the form of a ""Y"" and designed to connect compatible components [e.g., the tubing and face mask or an endotracheal (ET) tube] to create a breathing circuit. In order to function this device will be part of a breathing circui...
A connecting device shaped in the form of a "Y" or "T" and designed to connect compatible components [e.g., the tubing and face mask or an endotracheal (ET) tube] to create a breathing circuit. In order to function this device will be part of a breathing ci...
A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blo...
A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blo...
A device designed primarily to hold the breathing circuit tubing that carries gases from a ventilator and/or anaesthesia system to and from the patient. It is typically fixed to the ventilator/anaesthesia system, but can also be fixed to the patient's bed o...
A sterile, semi-rigid tube used in open heart surgery to facilitate the transfer of priming fluids during the priming of the extracorporeal circuit of a cardiopulmonary bypass system. It is a noninvasive product in the form of a tube or tubing used to chann...
A collection of sterile, flexible, plastic tube segments and associated items (e.g., connectors, line clamp, drip chamber) intended to be used in an apheresis system to channel blood from the patient to an appropriate apheresis column before being returned ...
A sterile length of flexible tube, typically made of synthetic polymer material(s), intended to be used in a blood autotransfusion system typically as an extension to channel blood between the bellows and the autotransfusion bag. The tubing may be used to m...
A complete portable assembly of noninvasive, non-powered devices intended to be used as part of an extracorporeal bypass system to provide short-term or prolonged (i.e., extra-surgical) mechanical circulatory life support during extracorporeal membrane oxyg...
A collection of disposable devices intended to be used with a lung donor-organ preservation/evaluation system to house, supply oxygen to, and/or manage preservation solution for, the preserved lung(s). It typically consists of the following components: a lu...
A disposable collection of devices intended to be used in a therapeutic plasma exchange (TPE) or red blood cell exchange system. It typically consists of tubing, solution lines, connection ports, a filter membrane and collection containers (bags) to channel...
A complete portable assembly of noninvasive, non-powered devices intended to be used as part of an extracorporeal bypass system to provide prolonged (i.e., extra-surgical) mechanical circulatory life support during extracorporeal membrane oxygenation (ECMO)...
A sterile, semi-rigid or rigid tube intended to be used during open heart surgery where it is surgically inserted for perfusion of the ascending aorta, serving as a channel for the transport of pumped, oxygenated, blood from a cardiopulmonary bypass system ...
A sterile, semi-rigid or rigid tube intended to be used during open heart surgery where it is surgically inserted, typically into the right atrium and superior/inferior vena cava, to serve as a channel for the transport of blood to a cardiopulmonary bypass ...
A length of flexible noninvasive tube(s) primarily intended to be connected between a tube/mask breathing circuit connector and a respiratory gas measuring instrument [e.g., a carbon dioxide (CO2) or multi-gas analyser, manometer/pressure monitor] for gas p...
A device designed to detect the presence and determine the concentration of oxygen (O2) by paramagnetic, electrochemical, or other technique. The device is typically used as a component of an oxygen monitor or a patient monitoring device/system that determi...
A length of flexible tube(s) primarily intended to be used as an interface between a tube/mask breathing circuit connector and a respiratory gas measuring instrument [e.g., a carbon dioxide (CO2) or multi-gas analyser, manometer/pressure monitor]. It may be...
A length of tube made of durable materials (e.g., rubber, silicone) intended to be used to conduct breathing gases towards or away from a patient during the respiratory cycle, typically during anaesthesia or ventilation [including continuous or bi-level pos...
A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-sh...
A length of tube made of durable materials (e.g., rubber, silicone) intended to be used to conduct breathing gases towards or away from a patient during the respiratory cycle, typically during anaesthesia or ventilation [including continuous or bi-level pos...
A device designed to provide or assist ventilation in a patient who is apnoeic or exhibits inadequate respiration through automatic pneumatic-driven pressure cycle functions. It is connected to a source of compressed oxygen (O2) and, if not entrained, medic...
A non-sterile length of flexible tube(s) primarily intended to be used as an interface between tube/mask breathing circuit connector and a measuring instrument [e.g., a carbon dioxide (C02) or multi-gas analyser, manometer/pressure monitor]. It may be inten...
A collection of sterile devices intended to support and provide continuous physiologic organ perfusion to a donated kidney(s) during its preservation, evaluation, and transport in a kidney donor-organ preservation/transport system from the donor to the rece...
A battery-powered instrument designed to continuously measure the concentration of oxygen (O2) inspired by a patient in a respiratory maintenance/therapy setting (e.g., O2 in an anaesthesia or ventilator breathing circuit, oxygen tent, oxygen therapy device...