A hollow, long, tubular electrical conductor with a sharply-pointed distal end intended for percutaneous introduction within soft tissue to deliver short electrical pulses, in a monopolar configuration, to produce irreversible cell membrane electroporation ...
A hollow, long, tubular electrical conductor with a sharply-pointed distal end intended for endoscopic introduction to deliver short electrical pulses, in a monopolar configuration, to produce irreversible cell membrane electroporation for ablation of soft ...
A male connecting device intended to be used to connect to a medical gas/vacuum pipeline system or other vacuum connection allowing a user to rapidly connect and disconnect vacuum dependent devices to the vacuum source. It has safety features such as a spec...
A device that is a component of a medical gas pipeline system or a medical gas/vacuum pipeline system that has a gas-specific outlet connection for nitrogen (N2). It is designed to be mounted to wall-mounted medical supply units, utility supply systems (cei...
A non-sterile device in the form of a closable housing intended to enclose and secure the connection (e.g., Luer connection) between mating components of a closed infusion system [e.g., closed system drug transfer device (CSTD)] attached to a patient’s IV l...
A male connecting device used to connect to the anaesthetic gas scavenging (AGS) terminal unit of a medical gas pipeline system or a female AGS connector allowing a user to rapidly connect and disconnect an anaesthetic gas scavenging system (AGSS) for the c...
An electronic device intended to be used with an ultrasound (US) imaging system to enable the simultaneous connection of multiple hand-held US transducers so the user can conveniently switch between transducers as required. It is a unit with multiple transd...
An electrically-powered device designed to use a wired or wireless connection to a hearing implant system (e.g., cochlear, bone-conduction, partially-implantable middle ear) sound processor to enhance the functionality and/or sound quality of the system. It...
A slender electrical conductor with a connection cable intended to be inserted within the lumen of an irreversible electroporation system percutaneous probe to deliver short electrical pulses, in a monopolar configuration, from a system generator to the pro...
A slender electrical conductor with a connection cable intended to be inserted within the lumen of an irreversible electroporation system probe (i.e., a percutaneous and/or endoscopic probe) to deliver short electrical pulses, in a monopolar configuration, ...
A sterile hand-held component of an electrosurgical system intended to provide an electrical connection between the system generator and a detachable electrode at its distal end, enabling the surgeon controlled manipulation of the electrode during surgery; ...
A male connecting device used to connect to a medical gas pipeline system or other gas source allowing a user to rapidly connect and disconnect nitrous oxide (N2O) dependent devices to the N2O supply. It has safety features such as a specific mechanical mat...
A hand-held component of an electrosurgical system intended to provide an electrical connection between the system generator and a detachable electrode at its distal end, enabling the surgeon controlled manipulation of the electrode during surgery; the elec...
A collection of sterile and non-sterile devices intended to be used with an insufflation gas conditioning system and/or a laparoscopic gas distention system, or other gas source, to condition the insufflation gas stream [typically carbon dioxide (CO2)] by h...
A hand-held component of an electrosurgical system intended to provide an electrical connection between the system generator and a detachable electrode at its distal end, enabling the surgeon controlled manipulation of the electrode during surgery; the elec...
A hand-held component of an electrosurgical system intended to provide an electrical connection between the system generator and a detachable electrode at its distal end, enabling the surgeon controlled manipulation of the electrode during surgery; the elec...
A male connecting device used to connect to a medical gas pipeline system or other gas source allowing a user to rapidly connect and disconnect oxygen (O2) dependent devices to the O2 supply. It has safety features such as a specific mechanical mating patte...
A male connecting device used to connect to a medical gas pipeline system or other gas source allowing a user to rapidly connect and disconnect medical air dependent devices to the medical air supply. It has safety features such as a specific mechanical mat...
A male connecting device used to connect to a medical gas pipeline system or other gas source allowing a user to rapidly connect and disconnect nitrogen (N2) dependent devices to the nitrogen supply. It has safety features such as a specific mechanical mati...
An electrically-powered device designed to use a wired or wireless connection to a hearing aid (e.g., bone-conduction) or hearing implant system (e.g., cochlear, bone-conduction, partially-implantable middle ear) sound processor to enhance its functionality...
A female connecting device used to accept a male anaesthetic gas scavenging (AGS) connector to connect two devices together to provide a continuous passageway for the controlled evacuation of exhaust anaesthesia gases. It has safety features such as a speci...
A male connecting device used to connect to a medical gas pipeline system or other gas source allowing a user to rapidly connect and disconnect helium/oxygen dependent devices to a mixture of 79% helium (He) and 21% oxygen (O2) supply. It has safety feature...
A female connecting device used to accept a male oxygen (O2) connector to connect two devices together to provide a continuous passageway for the delivery of O2. It has safety features such as a specific mechanical mating pattern, colour coding and a dedica...
A female connecting device used to accept a male nitrogen (N2) connector to connect two devices together to provide a continuous passageway for the delivery of nitrogen. It has safety features such as a specific mechanical mating pattern, colour coding and ...
A female connecting device used to accept a male vacuum connector to connect two devices together to provide a continuous passageway to the vacuum source. It has safety features such as a specific mechanical mating pattern, colour coding and a dedicated tub...
A device collection which includes flexible, noninvasive tubing (typically single or Y-shaped) and associated items (typically connectors, clamps, one-way valve and/or filter) intended to provide a connection between a surgical drain(s)/catheter(s) and a wo...
A device intended to allow electrical connection of incompatible plugs/sockets on related medical devices (e.g., generator and controller) and/or cables. This device will typically be used when the system components are from different manufacturers or using...
A female connecting device used to accept a male nitrous oxide (N2O) connector to connect two devices together to provide a continuous passageway for the delivery of N2O. It has safety features such as a specific mechanical mating pattern, colour coding and...
A female connecting device used to accept a male nitrous oxide/oxygen connector to connect two devices together to provide a continuous passageway for the delivery of a mixture of 50% nitrous oxide (N2O) and 50% oxygen (O2). It has safety features such as a...
A device collection which includes flexible, noninvasive, single-lumen tubing with connectors at each end intended to provide a connection between a surgical drainage catheter(s) and a closed-wound drainage suction pump; it also includes a one-way valve and...