A collection of devices used for the conveyance and collection of liquid/semi-liquid stool (faeces) from the rectum to a collection bag for a patient who is unable to control stool discharge. It typically includes a balloon catheter, a disposable collection...
A collection of devices intended to be used for the conveyance and collection of stool (faeces) from the rectum to a collection bag for a patient who is unable to control stool discharge. It typically includes a (balloon) catheter, disposable collection bag...
A non-bioabsorbable tubular device [bare metal stent (BMS)] intended to be implanted in a coronary artery or saphenous vein graft of the heart to maintain luminal patency and improve luminal diameter typically in a patient with symptomatic atherosclerotic h...
A non-bioabsorbable tubular device intended to be implanted in a renal artery to maintain arterial patency and improve luminal diameter in patients with symptomatic atherosclerotic disease. It is made of metal [e.g., stainless steel, cobalt-chrome (Co-Cr), ...
A sterile, non-bioabsorbable, tubular device intended to be implanted to indefinitely maintain patency/improve luminal diameter of a blood vessel (peripheral artery and/or vein) and, alternatively, the tracheobronchial tree; it may in addition be intended t...
A non-bioabsorbable, tubular device intended to be implanted to indefinitely maintain patency/improve luminal diameter of a blood vessel (peripheral artery and/or vein) and, alternatively, the tracheobronchial tree; it may in addition be intended to be used...
A sterile, flexible tube intended to be used for the percutaneous transluminal passage and placement of a diagnostic/interventional catheter, lead (e.g., pacing lead, balloon dilatation catheter), or guidewire through its lumen(s), within the vascular syste...
A flexible tube intended to be used for the percutaneous transluminal passage and placement of a diagnostic/interventional catheter, lead (e.g., pacing lead, balloon dilatation catheter), needle or guidewire through its lumen(s), within the vascular system....
A flexible tube intended to be used for the percutaneous transluminal passage and placement of a diagnostic/interventional catheter, lead (e.g., pacing lead, balloon dilatation catheter), or guidewire through its lumen(s), within the vascular system. It may...
A sterile, flexible, single-lumen tube intended to be used for the percutaneous transluminal passage and placement of a diagnostic/interventional catheter or lead (e.g., pacing lead, balloon dilatation catheter) through its lumen, within the vascular system...
A non-bioabsorbable tubular device intended to be implanted within the descending thoracic aorta to repair the vessel [includes repair of thoracic aortic aneurysm (TAA), traumatic transsections/dissections, fistulae, penetrating ulcers]. It is typically mad...
A sterile non-bioabsorbable tubular device intended to be implanted in an obstructed biliary duct (e.g., common bile duct) to maintain luminal patency. It may be a mesh structure or a continuous tube and is made entirely of metal [e.g., high-grade stainless...
A sterile non-bioabsorbable tubular device intended to be implanted within the descending thoracic aorta to repair the vessel [includes repair of thoracic aortic aneurysm (TAA), traumatic transsections/dissections, fistulae, penetrating ulcers]. It is typic...
A non-bioabsorbable tubular device intended to be implanted in an obstructed biliary duct (e.g., common bile duct) to maintain luminal patency; it is not intended for vascular implantation. It may be a mesh structure or a continuous tube and is made entirel...
A non-bioabsorbable tubular device intended to be implanted in the common and/or external iliac artery(ies) to maintain arterial patency and luminal diameter in patients with symptomatic atherosclerotic disease. It is made of metal [e.g., stainless steel, n...
A non-bioabsorbable tubular device intended to be implanted into an obstructed or stenosed trachea and/or bronchus/bronchiole to maintain luminal patency. It is made of both metallic and synthetic polymer materials (e.g., metal mesh with a polymeric cover/l...
A non-bioabsorbable tubular device intended to be implanted within the descending thoracic aorta to repair the vessel [includes repair of thoracic aortic aneurysm (TAA), traumatic transsections/dissections, fistulae, penetrating ulcers]; it is not intended ...
A non-bioabsorbable tubular device intended to be implanted in the aorta to maintain aortic patency and improve luminal diameter in patients with symptomatic atherosclerotic disease or recurrent coarctation (narrowing) of the aorta. It is made of metal (e.g...
A sterile non-bioabsorbable tubular device intended to be implanted in the aorta to maintain aortic patency and improve luminal diameter in patients with symptomatic atherosclerotic disease or recurrent coarctation (narrowing) of the aorta. It is made of me...
A sterile non-bioabsorbable tubular device intended to be implanted in the common and/or external iliac artery(ies) to maintain arterial patency and luminal diameter in patients with symptomatic atherosclerotic disease. It is made of metal [e.g., stainless ...
A non-bioabsorbable tubular device intended to be implanted in an obstructed biliary duct (e.g., common bile duct) to maintain luminal patency. It is a mesh structure made of metal which is covered/lined with a synthetic polymer material (e.g., silicone) th...
A sterile non-bioabsorbable tubular device intended to be implanted in an obstructed biliary duct (e.g., common bile duct) to maintain luminal patency. It is a mesh structure made of metal which is covered/lined with a synthetic polymer material (e.g., sili...
A sterile non-bioabsorbable tubular device intended to be implanted in the lumen of the duodenum for the palliative treatment of duodenal strictures caused by malignant neoplasms; it is typically used to help eliminate gastric outlet obstructions. It is typ...
A sterile non-bioabsorbable tubular device intended to be implanted into an obstructed or stenosed trachea and/or bronchus/bronchiole to maintain luminal patency. It is made of both metallic and synthetic polymer materials (e.g., metal mesh with a polymeric...
A non-bioabsorbable tubular device intended to be implanted into an obstructed or stenosed trachea and/or bronchus/bronchiole to maintain luminal patency. It may be a straight or branched mesh structure, or continuous tube, and is made of metal [e.g., high-...
A non-bioabsorbable, expandable, tubular device intended to be implanted into the oesophagus to maintain luminal patency in strictures (e.g., from intrinsic/extrinsic malignant tumours) or to reduce acute bleeding from oesophageal varices. It is typically a...
An expandable device intended to be inflated in the stomach to create a feeling of satiety and reduce the desire for food. The device is inserted via a catheter and may be retained in the stomach where it degrades over a period. Disposable devices dedicated...
A non-bioabsorbable tubular device wrapped in a flexible fine mesh dedicated to implantation in a carotid artery to improve its luminal diameter in patients with atherosclerotic carotid artery disease. It consists of a metal framework with a polymeric mesh ...
A non-bioabsorbable tube intended to be endoscopically implanted transmurally between the gastrointestinal (GI) tract and a pancreatic pseudocyst or the biliary tract for drainage. It is a flanged stent-like structure made of metal which is covered/lined wi...
A non-bioabsorbable tubular or ring-like device intended to be implanted indefinitely/long-term in the urethra to facilitate urethral patency and an unimpeded flow of urine from the bladder; it is typically used to relieve obstructions from bulbar urethral ...