A cylindrical rod used preoperatively as a precision guide to align an orthopaedic implant aiming arm with, e.g., an intramedullary bone nail (femoral, humeral, and tibial) that will be implanted. It is inserted through the guiding locking holes of the adju...
A sterile device designed to seal the sheath of a haemostasis valve to maintain sheath patency (i.e., to prevent blood from coagulating in the sheath and blocking access through the haemostasis valve). It is typically a long, thin, rod-like device made of p...
A sterile rod made of metal or other material which, when inserted into the intramedullary canal of the femur, acts to immobilize by holding the ends of a fractured bone in position to promote healing. The device may also be used to support the bone in the ...
A sterile device consisting of a calibrated barrel (cylinder) with plunger intended to be used for injection/withdrawal of fluids/gas (e.g., medication) to/from a medical device or the body (i.e., capable of both); a needle is not included. It is intended f...
A rigid rod made of metal or other material intended to be implanted into the intramedullary canal of the femur to immobilize the ends of a fractured bone in position to promote healing; it is not dedicated to extension beyond the joint to an adjacent bone ...
A sterile rod made of metal or other material which, when inserted into the intramedullary canal of the tibia, acts to immobilize by holding the ends of a fractured bone in position to promote healing. The device may also be used to support the bone in the ...
A non-sterile rod made of metal or other material which, when inserted into the intramedullary canal of the femur, acts to immobilize by holding the ends of a fractured bone in position to promote healing. The device may also be used to support the bone in ...
A rod made of metal or other material intended to be implanted into the intramedullary canal of the femur to immobilize the ends of a fractured bone in position to promote healing; it also be used to support the bone in the presence of a pathological condit...
A self-locking surgical instrument designed to force apart two adjacent ribs to permit examination or intervention in the thoracic cavity. This device will typically have two interchangeable blades at the distal end that hook over the ribs to be parted, and...
A self-locking, surgical instrument, used for separating the edges or drawing aside the margins of a surgical incision to permit excision of the lamina of the vertebral posterior arch; this can be necessary to expose a portion of the spinal cord for removal...
A rigid rod made of metal or other material intended to be implanted into the intramedullary canal of the tibia to immobilize the ends of a fractured bone in position to promote healing; it is not dedicated to extension beyond the joint to an adjacent bone ...
A rod made of metal or other material intended to be implanted into the intramedullary canal of the tibia to immobilize the ends of a fractured bone in position to promote healing. The device may also be used to support the bone in the presence of a patholo...
A device intended to connect to a surgical power tool system motor [it is locked and held in a collet or quick coupling and not simply gripped in a drill chuck (Jacobs chuck)] to convert the non-dedicated mechanical energy provided by the motor to a dedicat...
A sterile rod made of metal or other material which, when inserted into the intramedullary canal of the humerus, acts to immobilize by holding the ends of a fractured bone in position to promote healing. The device may also be used to support the bone in th...
A non-sterile rod made of metal or other material which, when inserted into the intramedullary canal of the tibia, acts to immobilize by holding the ends of a fractured bone in position to promote healing. The device may also be used to support the bone in ...
A connecting device designed as a mechanical coupling to join and lock together a distal tool to the surgical power tool to provide the power when these are incompatible and are of a different manufacture/industry standard. It is typically made from high-gr...
A plastic pouch designed to be attached around a stoma for use as a receptacle for intestinal output following a colostomy or ileostomy (effluent is typically of a fluid consistency). It consists of two or more separate parts including the pouch with a flan...
A strap or tubing intended to be wrapped around a patient's limb (arm or leg) and manually tightened to reduce blood circulation to or from the portion of the limb distal to where the device is applied. It is typically used by emergency medical services (EM...
A hand-held manual surgical instrument designed to hook skin or tissue in order to grasp, apply traction, and lift the skin/tissue during a surgical intervention. It is typically a shaft-like instrument with small double hooks at the distal end and a handle...
A rod-like orthopaedic surgical instrument designed to be inserted (screwed) through the insertion handle of an orthopaedic implant aiming arm to impart a force upon a proximally inserted bone nail locking screw thus creating compression on the proximal sec...
A self-locking surgical instrument designed to force apart the surgically-split sternum (the breastbone) to permit surgical cardiac intervention within the thoracic cavity. This device will typically have two interchangeable profiled, pivoted blades (self-a...
A rigid rod made of metal or other material intended to be implanted into the intramedullary canal of the humerus to immobilize the ends of a fractured bone in position to promote healing; it may also be used to support the bone in the presence of a patholo...
A device that is an interchangeable component of an orthopaedic chisel and functions as the cutting blade which is attached and locked to a dedicated handle. Together, they become a single-blade surgical instrument, bevelled on one side, intended to cut or ...
A sterile, rigid, manual instrument designed to facilitate blunt dissection between tissue planes during laparoscopic procedures, and may additionally be used during open surgical interventions of the abdomen. It is typically made of high-grade stainless st...
A non-sterile device consisting of a calibrated barrel (cylinder) with plunger intended to be used for injection/withdrawal of fluids/gas (e.g., medication) to/from a medical device or the body (i.e., capable of both); it is intended for various medical app...
A non-sterile strap or tubing intended to be wrapped around a patient's limb (arm or leg) and manually tightened to reduce blood circulation to or from the portion of the limb distal to where the device is applied. It is typically used by emergency medical ...
A non-sterile rod made of metal or other material which, when inserted into the intramedullary canal of the humerus, acts to immobilize by holding the ends of a fractured bone in position to promote healing. The device may also be used to support the bone i...
A rod made of metal or other material intended to be implanted into the intramedullary canal of the humerus to immobilize the ends of a fractured bone in position to promote healing. The device may also be used to support the bone in the presence of a patho...
A device intended to connect to a surgical power tool system motor [it is locked and held in a collet or quick coupling and not simply gripped in a drill chuck (Jacobs chuck)] to convert the non-dedicated mechanical energy provided by the motor to a dedicat...
A strap or tubing intended to be wrapped around a patient's limb (arm or leg) and manually tightened to reduce blood circulation to or from the portion of the limb distal to where the device is applied. It is typically used by emergency medical services (EM...