Search

30 matching records for Data Cable.

GMDN Terms#

Electrical-only medical device connection cable, single-use

939 GUDID devices

A non-patient-contact, insulated, electrical cord with a connector (plug) at both ends designed to transmit electrical power and/or signal (data) between medical devices (e.g., to connect a lead, electrical catheter, handpiece, or monitor to a parent device...

Video-camera epiretinal prosthesis system camera spectacles

12 GUDID devices

An electronic component of a video-camera epiretinal prosthesis system in the form of custom-made spectacles worn by the patient. The device houses a miniature video camera designed to capture video images which are relayed to the system visual processing u...

Noninvasive device battery charger/transceiver/cable

6 GUDID devices

An electrically-powered device designed to supply an electrical charge to the battery of a noninvasive device to recharge it for operation, and to both receive data from and transmit data to noninvasive devices via a direct/wired or wireless connection. It ...

Intracardiac pacemaker programming interface unit

1 GUDID devices

An external, electronic device intended to interface a dedicated patient lead (cable with skin surface electrodes) with a pacemaker programmer (from which it draws its power), to enable noninvasive interrogation and programming of an implanted intracardiac ...

Electrical-only medical device connection cable, reusable

10,765 GUDID devices

A non-patient-contact, insulated, electrical cord with a connector (plug) at both ends designed to transmit electrical power and/or signal (data) between medical devices (e.g., to connect a lead, electrical catheter, handpiece, or monitor to a parent device...

Electrical-only medical device connection cable, reprocessed

452 GUDID devices

A non-patient-contact, insulated, electrical cord with a connector (plug) at both ends designed to transmit electrical power and/or signal (data) between medical devices (e.g., to connect a lead, electrical catheter, handpiece, or monitor to a parent device...

Ambulatory monitoring/recording system transceiver/cable

10 GUDID devices

An electronic component of an ambulatory patient monitoring/recording system (e.g., ocular volume ambulatory recording system) designed to connect a patient-worn antenna to an ambulatory monitor/recorder for receiving and transmitting data between an implan...

Noninvasive device battery charger

1,355 GUDID devices

An electrically-powered device designed to supply an electrical charge, via a direct/wired or wireless connection, to the battery of a noninvasive device to recharge it for operation; it is not intended to receive data from and transmit data to other device...

Central venous catheter navigation system, electrocardiographic

132 GUDID devices

An assembly of noninvasive devices intended to use electrocardiographic (ECG) data to assist guidance and positioning of a central venous catheter [e.g., peripherally-inserted central catheter (PICC), central venous catheter (CVC), haemodialysis catheter]. ...

Central venous catheter navigation system control unit

56 GUDID devices

A portable mains electricity (AC-powered) component of an electrocardiographic central venous catheter navigation system intended to process and display electrocardiographic (ECG) data to assist guidance and positioning of a central venous catheter [e.g., p...

Neuromuscular motion disorder ambulatory recorder/analyser

10 GUDID devices

An assembly of devices intended for 24-hour recording of body movements of a patient affected by a neuromuscular kinetic disorder (e.g., Parkinson’s disease) for analysis. It consists of battery-powered, home-use, externally-worn (e.g., wrist, leg, head) pa...

Urine monitoring system monitor

2 GUDID devices

A battery-powered, portable device that automatically and continuously displays urine output data (urine flow/volume) received via a cable from a urine monitoring system's output sensor to provide optimal renal and fluid management information when this is ...

Cochlear implant system coil

150 GUDID devices

The non-sterile external portion of a cochlear implant system [cochlear implant (CI)] that typically consists of a battery-powered, behind-the-ear (BTE) transmitter designed to transmit direct current (DC) and stimulation data (electrical signals) to the im...

Air/gas pressure transducer

123 GUDID devices

A noninvasive electronic device designed to convert air or gas pressure signals into electrical signals for subsequent display or processing by a parent device (e.g., physiological data recorder, gastrointestinal motility analysis system). It may be a compa...

Electroencephalographic monitoring system

97 GUDID devices

An electrically-powered device assembly designed to continuously measure the electrical signals produced by a patient's brain and display/record them as an electroencephalogram (EEG) to evaluate brain function, typically in an examination room or intensive ...

Transcutaneous blood gas monitoring system

71 GUDID devices

An assembly of mains electricity (AC-powered) devices designed for the continuous and transcutaneous measurement of a patient's blood gas parameters, typically blood partial pressure of oxygen (pO2), blood partial pressure of carbon dioxide (pCO2), haemoglo...

Breathing circuit gas-flow sensor, reusable

47 GUDID devices

A device that includes a transducer intended to detect the movement of gases in a breathing circuit, and convert this into an electrical signal for relay to a ventilator (e.g., adult/paediatric/neonatal ventilators, anaesthesia system ventilators). It is co...

Tissue saturation oximeter

44 GUDID devices

A mains electricity (AC-powered) photoelectric device that noninvasively calculates the percent oxygen saturation of haemoglobin in a volume of tissue (StO2) to assess the amount of oxygen delivered to that tissue, typically during circulatory or perfusion ...

Home-use sleep apnoea recording system

36 GUDID devices

A battery-powered device assembly intended to continuously measure and record patient physiological parameters (e.g., arterial oxygen saturation level, pulse rate, respiration effort/pattern, airflow waveform) during sleep in the home, to facilitate the dia...

Breathing circuit gas-flow sensor, single-use

7 GUDID devices

A sterile device that includes a transducer intended to detect the movement of gases in a breathing circuit, and convert this into an electrical signal for relay to a ventilator (e.g., adult/paediatric/neonatal ventilators, anaesthesia system ventilators). ...

Video capsule endoscopy monitoring kit

6 GUDID devices

A collection of noninvasive devices intended to assist with the monitoring of image data from an ingested video capsule (not included), as it passes through the gastrointestinal (GI) tract. It typically consists of a monitor, an antenna that receives the wi...

Video capsule endoscopy system antenna

6 GUDID devices

An electrically-powered, noninvasive component of a video capsule endoscopy system designed to be attached to/worn by a patient to receive the image data signals from an ingested video capsule and transmit them to the system monitor. It typically has the fo...

Cochlear implant assessment system

5 GUDID devices

An assembly of non-sterile portable electronic devices designed to perform an integrity test on the implantable portion of a cochlear implant (CI) system in situ; the test is intended to provide objective data on implant function and aid in the assessment o...

Central venous catheter navigation system support kit

4 GUDID devices

A collection of sterile, noninvasive devices intended to assist use of a central venous catheter navigation system during electrocardiographic (ECG) supported guidance and positioning of a central venous catheter. The kit is dedicated to ECG-supported cathe...

Hearing implant implantable-component tester, postoperative

4 GUDID devices

A portable electronic device designed to perform an integrity test on the implantable portion of a hearing implant [e.g., cochlear implant (CI)] system in situ postoperatively (e.g., during routine checks); the test is intended to provide objective data on ...

Video-camera epiretinal prosthesis system visual processing unit

3 GUDID devices

A battery-powered, body-worn component of a video-camera epiretinal prosthesis system designed to convert video images captured by the system spectacles camera into electrical stimulation commands, which are relayed to the system implant via the spectacles....

Transcutaneous blood gas monitoring system

2 GUDID devices

An assembly of electrically-powered devices designed for the continuous and transcutaneous measurement of a patient's blood gas parameters, typically blood partial pressure of oxygen (pO2), blood partial pressure of carbon dioxide (pCO2), haemoglobin oxygen...

Orthopaedic knee-balance analyser, electrically-powered

1 GUDID devices

An electrically-powered orthopaedic device intended for measurement of the forces within the knee joint during a total knee arthroplasty (TKA) to assist with further planning of the procedure. It is typically a hand-held device with prongs to push against t...