A detachable plastic cap for an endoscope (e.g., duodenoscope) designed to cover the exposed mechanical components at the distal end of the endoscope during a single use. It is intended as an alternative to the common non-detachable distal end-cap of an end...
A device designed to fit over the distal end of a hand-held, non-surgically-invasive device with optical functionality (e.g., laser beam-guide, optical scanning handpiece, endoscope) during use to act as a cover/shield to avoid cross-contamination between p...
A non-sterile device used in pairs that are placed/fitted onto the distal working end (the jaws) of surgical instruments (e.g., vascular clamps, haemostats and forceps) to provide improved atraumatic grip and even pressure distribution when clamping an arte...
A device designed to fit over the distal end of a non-surgically-invasive device with optical functionality (e.g., laser beam-guide, optical scanning handpiece, endoscope) during use, to act as a cover/shield to avoid direct contact to the eye and/or cross-...
A plastic cap/cover designed to be placed onto the distal end of an endoscope to allow white balance and/or 3-D adjustment to be calibrated in the electronic control unit of the endoscope. This is a reusable device.
A composite material cap/cover designed to be placed onto the distal end of an endoscope to allow auto-fluorescence imaging colour balance to be calibrated in the electronic control unit of the endoscope. This is a single-use device.
A sterile rigid tube designed to provide body tissue access through its lumen for a radio-frequency (RF) probe during RF ablation procedures (typically of peripheral nerves to treat chronic pain) and for the injection/aspiration of fluids (e.g., local anaes...
A rigid tube designed to provide percutaneous (through the skin) tissue access through its lumen for an electrosurgical probe during radio-frequency (RF) ablation procedures (typically of peripheral nerves to treat chronic pain) and for the injection/aspira...
A rigid tube designed to provide percutaneous (through the skin) tissue access through its lumen for an electrosurgical probe during radio-frequency (RF) ablation procedures (typically of peripheral nerves to treat chronic pain) and for the injection/aspira...
A rigid tube designed to provide body tissue access through its lumen for a radio-frequency (RF) probe during RF ablation procedures (typically of peripheral nerves to treat chronic pain) and for the injection/aspiration of fluids (e.g., local anaesthetic a...
A surgical instrument used for stretching or enlarging the fascial tissue covering a cavity, tract, or opening typically prior to the introduction of a catheter during an invasive diagnostic or interventional procedure (e.g., femoral artery catheterization)...
A hand-held surgical instrument, usually softly rounded and curved at the working end, used to separate the outermost membrane covering of the brain and spinal cord from the inner membranes. It is usually designed with a handle which continues into a shaft ...
A surgical instrument designed to apply pressure to and/or cut the crescent-shaped disk of fibrocartilage that borders and partly covers the articulating surfaces of the tibia and femur at the knee (meniscus). At the proximal end is a handle, sometimes T-sh...
A sterile cover, used in pairs, fitted onto the distal working end (the jaws) of artery forceps, vascular clamps, or similar surgical instruments, to provide improved grip for delicate sutures. It is typically tube-like with a closed, rounded tip and compos...
A metal or plastic bracket manually applied to a hand-held ultrasound (US) transducer intended to provide a means to attach/hold an electromagnetic (EM) sensor or needle guide to the distal end of the US transducer in a repeatable position (can detach/reatt...
A device used in pairs that are placed/fitted onto the distal working end (the jaws) of a surgical instrument (e.g., vascular clamps, forceps) to improve atraumatic grip and pressure distribution when clamping an artery or a vein. It is typically a long cyl...
A sterile device used in pairs that are placed/fitted onto the distal working end (the jaws) of surgical instruments (e.g., vascular clamps, haemostats and forceps) to provide improved atraumatic grip and even pressure distribution when clamping an artery o...
A surgical instrument used for stretching or enlarging the fascial tissue covering a cavity, tract, or opening typically prior to the introduction of a catheter during an invasive diagnostic or surgical procedure (e.g., femoral artery catheterization). It i...
"A sterile cover, used in pairs, fitted onto the distal working end (the jaws) of artery forceps, vascular clamps, or similar surgical instruments, to provide improved grip for delicate sutures. It is typically tube-like with a closed, rounded tip and compo...
An artificial kneecap (patellar component) covered with metal on its outer surface and implanted during primary or revision bicondylar knee joint replacement. It is a sterile device designed to articulate with a prosthetic distal femoral component and is im...
An implantable device covered with metal on its outer surface intended to fully or partially replace the patella (kneecap) as part of a bicondylar knee joint replacement (primary or revision). It is designed to articulate with a prosthetic distal femoral co...
A non-sterile, smooth, capsule-like device intended to house/cover a tracheoesophageal device (e.g., speech valve, fistula gauge) at the distal end of the introduction assembly, to enable atraumatic insertion of the device into the tracheoesophageal fistula...
An invasive device, typically in the form of a detachable cap, designed to cover the exposed mechanical components at the distal end of an endoscope (e.g., duodenoscope) during an endoscopic procedure to protect the patient from injury. This is a single-use...
A removable attachment to an ultrasonic surgical system handpiece intended to contain the flow of coolant liquid, supplied through the handpiece, over the ultrasonic surgical system handpiece tip; the coolant is intended to prevent overheating of the tip du...
A non-sterile component of an intraoperative/postoperative therapeutic x-ray system designed to be attached to and cover the x-ray source for direct patient contact when the system is used for the treatment of certain clinical conditions (e.g., skin tumours...
A sterile, rigid, laparoscopic device, covered with a sheath of electrical insulation, designed to perform through a compatible laparoscopic instrument (e.g., an access port) and to be connected to an electrosurgical diathermy generator when required to pro...
A non-sterile component of an intraoperative/postoperative therapeutic x-ray system designed to be attached to and cover the x-ray source for direct patient contact when the system is used in the treatment of certain clinical conditions (e.g., breast cancer...
A sterile, noninvasive, flexible sleeve intended to be used during cardiovascular catheterization (e.g., femoral, pulmonary) to cover and protect the exposed proximal end of a cardiovascular catheter to prevent contamination (extending the sterile field of ...
A non-sterile component of an intraoperative/postoperative therapeutic x-ray system designed to be attached to and cover the x-ray source for direct patient contact when the system is used for the treatment of certain clinical conditions (e.g., intra-abdomi...
A component of an intraoperative/postoperative therapeutic x-ray system designed to be attached to and cover the x-ray source for direct patient contact when the system is used in the treatment of certain clinical conditions (e.g., breast cancer). It has a ...