New Wave Cleaning Solutions Foaming Hand Sanitizer
BENZALKONIUM CHLORIDE
129 matching records for E-Wave.
BENZALKONIUM CHLORIDE
ALUMINUM ZIRCONIUM OCTACHLOROHYDREX GLY
ALUMINUM ZIRCONIUM OCTACHLOROHYDREX GLY
ALCOHOL HAND SANITIZER
ETHYL ALCOHOL
ALCOHOL
ALUMINUM ZIRCONIUM OCTACHLOROHYDREX GLY
ALCOHOL HAND SANITIZER
ALUMINUM CHLOROHYDRATE
AVOBENZONE, HOMOSALATE, OCTISALATE
ALUMINUM ZIRCONIUM OCTACHLOROHYDREX GLY
ALUMINUM ZIRCONIUM OCTACHLOROHYDREX GLY
BENZALKONIUM CHLORIDE
AVOBENZONE, HOMOSALATE, OCTISALATE
alcohol
AVOBENZONE, HOMOSALATE, OCTISALATE, OCTOCRYLENE
Aluminum Zirconium Octachlorohydrex Gly
Aluminum Zirconium Octachlorohydrex Gly
Ethyl Alcohol
Alcohol Hand Sanitizer
Aluminum chlorohydrate
Aluminum Zirconium Octachlorohydrex Gly
Aluminum Zirconium Octachlorohydrex Gly
Aluminum Zirconium Octachlorohydrex Gly
Alcohol Hand Sanitizer
Isopropyl Alcohol
BENZALKONIUM CHLORIDE
BENZALKONIUM CHLORIDE
Aluminum Zirconium Octachlorohydrex Gly
Aluminum Zirconium Octachlorohydrex Gly
Aluminum Zirconium Tetrachlorohydrex Gly
OCTINOXATE, OXYBENZONE, PADIMATE O
OCTINOXATE, OXYBENZONE
BENZALKONIUM CHLORIDE
ALCOHOL
Aluminum chlorohydrate
Aluminum Zirconium Octachlorohydrex Gly
Aluminum Zirconium Octachlorohydrex Gly
Aluminum Zirconium Octachlorohydrex Gly
Aluminum Zirconium Octachlorohydrex Gly
Aluminum Zirconium Tetrachlorohydrex Gly
ISOPROPYL ALCOHOL
ISOPROPYL ALCOHOL
DENATURED DT ETHYL ALCOHOL
DENATURED DT ETHYL ALCOHOL
Alcohol
Alcohol
Alcohol
Alcohol
Alcohol
Alcohol
Alcohol
Alcohol
Alcohol
Alcohol
Alcohol
ALCOHOL
Ethyl Alcohol
ALCOHOL
ALCOHOL
ALCOHOL
ALCOHOL
ALCOHOL
Alcohol hand Sanitizer
20260625
20260624
20260624
20260410
20260409
20260114
20251231
20250922
20250306
20250225
20241127
20241106
20240104
20231023
20230616
20220127
20220118
20210202
20210115
20200902
20200902
20200831
20200830
20200730
20200708
20200626
20200618
20200604
20200528
20180226
20121016
20120906
2020-04-30
2026-02-27
2026-01-26
An assembly of devices designed to provide electromechanical orthopaedic extracorporeal shock wave therapy (OEST) and pneumatic pressure wave therapy to treat musculoskeletal disorders. It is typically mobile and includes a control unit that uses both an el...
An assembly of devices designed to provide spark-gap-generated extracorporeal shock wave therapy (ESWT) intended to treat acute and chronic conditions of the skin and subcutaneous soft tissues (e.g., arterial, venous, diabetic or pressure ulcers; burns; pos...
An assembly of devices designed to provide spark-gap-generated extracorporeal shock wave therapy (ESWT) intended to treat acute and chronic conditions of the skin and subcutaneous soft tissues (e.g., arterial, venous, diabetic or pressure ulcers; burns; pos...
An instrument with an integrated ultrasound transducer used for the detection and temporary occlusion of blood vessels during a surgical procedure. It is typically a held-hand device that is placed on the vasculature to be affected. It is connected to an ap...
A hand-operated electrical conductor that is a component of a medium-wave diathermy treatment system and designed to be moved over the skin surface of a patient by an operator to deliver an electrical current at a pre-set frequency to develop heat in subcut...
An assembly of devices designed to provide pneumatic orthopaedic extracorporeal shock wave therapy (OEST) to treat musculoskeletal disorders. It typically consists of a control unit that produces pneumatically-generated shock waves at selected impulse frequ...
An assembly of devices designed to provide electromechanical orthopaedic extracorporeal shock wave therapy (OEST) to treat musculoskeletal disorders. It is typically portable and includes a control unit that uses an electrical current to create kinetic ener...
A component of a medium-wave diathermy treatment system that generates electromagnetic (EM) energy, in the radio-frequency (RF) bands of 0.5 megahertz (MHz) to 1 MHz, applied transcutaneously to provide a deep heat within specific volumes of a patient's bod...
An electrically-powered assembly of devices designed to provide noninvasive spark-gap-generated (electrohydraulic) extracorporeal shock wave therapy [ESWT] to treat a variety of conditions (e.g., tendinopathy, plantar fasciitis, acute wounds, pelvic pain) a...
A component of a short-wave therapeutic diathermy system designed to generate electromagnetic (EM) energy in the radio-frequency (RF) bands of 13 megahertz (MHz) to 27.12 MHz applied transcutaneously to provide a deep heat within specific volumes of the bod...
An electrical conductor that is a component of a short-wave diathermy treatment system and designed for the transfer of electromagnetic (EM) energy in the radio-frequency (RF) bands of 13 megahertz (MHz) to 27.12 MHz from the system's generator to the patie...
A mobile assembly of devices designed to provide spark-gap-generated orthopaedic extracorporeal shock wave therapy (OEST) to treat musculoskeletal disorders. It typically consists of a generator with two submerged electrodes that produce spark-gap (electroh...
An assembly of devices that non-invasively disintegrates stones (i.e., calculi) by sending focused shock waves from outside the body produced by a spark-gap generator. The generator delivers shock waves when an electrical discharge between two electrodes su...
A hand-held component of a dermatological extracorporeal shock wave therapy (ESWT) system designed to transmit spark-gap-generated (electrohydraulic) shock waves to treat acute and chronic conditions of the skin and subcutaneous soft tissues (e.g., arterial...
An assembly of devices using extracorporeal pulse activation technology (EPAT) and designed for acoustic wave treatment (AWT) intended primarily to reduce the appearance of cellulite through mobilization of free fatty acids and oxidative agents in tissue. I...
A hand-held, electrically-powered assembly of devices designed to provide noninvasive extracorporeal shock wave therapy [ESWT] (e.g., spark-gap-generated, piezoelectric) to treat a variety of conditions (e.g., tendinopathy, plantar fasciitis, acute wounds, ...
A mains electricity (AC-powered) device assembly in which input energy (e.g., flashlamp, diode laser) is used to excite a glass/crystal rod to emit a high-power laser beam, in which the frequency is doubled, intended to precisely cut, excise/vaporize, and c...
A mains electricity (AC-powered) device assembly in which input energy (e.g., flashlamp, diode laser) is used to excite a glass/crystal rod to emit a high-power laser beam intended to cut, excise, ablate, and vaporize soft tissues in dermatological applicat...
A hand-held, battery-powered device assembly consisting of a graphical display unit and an attached probe or interchangeable probes, designed to noninvasively locate and assess the extent of vascular flow restriction (e.g., clots, stenosis, mechanical damag...
An assembly of devices intended to provide visual and/or auditory signals corresponding to the status of one or more of a patient's physiological functions, e.g., brain wave activity, muscle activity, blood pressure, skin temperature, balance, so that the p...
An electrically-powered device assembly designed to continuously measure the electrical signals produced by a patient's brain and display/record them as an electroencephalogram (EEG) to evaluate brain function, typically in an examination room or intensive ...
An assembly of devices that non-invasively disintegrates stones (i.e., calculi) by sending focused shock waves from outside the body produced by a piezoelectric generator. This generator contains an array of up to 4,000 ceramic elements arranged on a spheri...
A noninvasive, electrically-powered, entirely patient-worn device assembly intended to improve venous and lymphatic return from the leg to help treat/prevent venous disorders/sequelae (e.g., swelling, pain, thrombosis). It consists of an electronic processo...
A mains electricity (AC-powered) device assembly in which input energy (e.g., flashlamp, diode laser) is used to excite a glass/crystal rod to emit a high-power laser beam intended to cut, excise, ablate, and vaporize soft tissues in dermatological applicat...
A mains electricity (AC-powered) device assembly consisting of a desktop unit, a graphical display unit and an attached probe or interchangeable probes, designed to noninvasively locate and assess the extent of vascular flow restriction (e.g., clots, stenos...
An assembly of devices designed to produce a therapeutic deep heat within specific volumes of the body through the transcutaneous transmission of electromagnetic (EM) energy in the radio-frequency (RF) bands of 0.5 megahertz (MHz) to 1 MHz. It typically con...
A mains electricity (AC-powered) device designed to detect, measure, and display foetal heart activity during the perinatal period. Typically foetal heart rate is measured, but heart valve movement can also be assessed. The device operates noninvasively by:...
An assembly of devices that non-invasively disintegrates stones (i.e., calculi) by sending focused shock waves from outside the body produced by an electromechanical generator. This generator contains a coil attached to a thin metallic membrane; a magnetic ...
A mains electricity (AC-powered) device assembly designed to continuously measure the electrical signals produced by a patient's brain and display/record them as an electroencephalogram (EEG) to evaluate brain function. It may be capable of monitoring vario...
A mains electricity (AC-powered) device assembly designed to continuously measure the electrical signals produced by a patient's brain and display/record them as an electroencephalogram (EEG) to evaluate brain function. It may be capable of monitoring vario...