A sterile electrical conducting device designed to be inserted percutaneously into muscle or nerve tissue to detect bioelectrical signal activity. It is a needle-like device (a needle electrode with an electrical connector at the proximal end) that is conne...
A sterile electrical-conducting strip intended to be attached to an endotracheal tube to conduct the electromyographic (EMG) activity of the laryngeal and vocal cord musculature while the tube is in situ. It is used to assess the status of the nerves supply...
An electrical conducting device designed to be inserted percutaneously into muscle or nerve tissue to detect bioelectrical signal activity. It is a needle-like device (a needle electrode with an electrical connector at the proximal end) that is connected to...
An electrically-powered unit designed for the measurement and recording of the intrinsic electrical potential of skeletal muscle for display in the form of a graph [electromyograph (EMG)], typically for diagnosis of muscle and/or nerve disorders. It is desi...
A sterile hollow cylinder intended to be inserted orally or nasally into the trachea to provide an unobstructed airway to convey gases and vapours to and from the lungs during anaesthesia, resuscitation, and other situations where the patient is not properl...
A portable, electrically-powered device intended to produce electrical impulses for electrical nerve stimulation and to obtain and display electromyography (EMG) readings (visual and/or audio) to locate nerves and muscle, to facilitate accurate intramuscula...
An electrically-powered device designed to continuously measure electrical signals from a patient’s skeletal muscle and display/record the signals as an electromyograph (EMG) to evaluate brain/nerve function, typically during a surgical procedure. It includ...
An insulated metal wire(s) designed to conduct electrical signals between a skin electrode(s) or needle electrode(s) [electrode not included] and a device designed for electrophysiological recording/monitoring [e.g., electromyography (EMG), evoked potential...
An insulated metal wire(s) designed to conduct electrical signals between a skin electrode(s) or needle electrode(s) [electrode not included] and a device designed for electrophysiological recording/monitoring [e.g., electromyography (EMG), evoked potential...
A collection of dedicated electrodes intended to support a variety of electrophysiological measurements [e.g., electrocardiography (ECG), electroencephalography (EEG), electromyography (EMG), intraoperative monitoring (IOM), evoked potentials (EP)]. It incl...
A sterile, multi-purpose electrical conductor inserted beneath the dermal layer of a patient's skin to record/monitor electrical activity (biopotentials) for physiological measurements [typically electroencephalography (EEG), electromyography (EMG), and evo...
A mains electricity (AC-powered) device designed to record physiological signals from a sleeping patient to assess sleep disorders (e.g., insomnia, snoring or sleep apnoea). The device is typically computerized and usually records an electrocardiogram (ECG)...
An assembly of mains electricity (AC-powered) devices designed to monitor and provide electrical stimuli to spinal nerves or other neural pathways (may include the brain) during intraoperative surgery or intensive care, typically to reduce the incidence of ...
An electrical conductor designed to be attached to the skin surface of a patient outside of the hair line (i.e., non-scalp) to conduct electrical signals to/from a parent device for electrophysiological recording/monitoring [e.g., electromyography (EMG), ev...
A non-sterile, electrical conductor designed to be attached to the skin surface of a patient outside of the hair line (i.e., non-scalp) to conduct electrical signals to a parent device for electrophysiological recording/monitoring [e.g., electromyography (E...
An multicomponent assembly of electrically-powered devices designed to locate a nerve by applying an electrical stimulus with a probe and observing muscle responses. Once the pathways are located, their transmission capabilities can be assessed by comparing...
A computerized device assembly designed for analysis and real-time feedback (biofeedback) of a variety of physiological parameters [e.g., heart rate, respiration, skin conductance, skin temperature, range of motion, force output, electroencephalography (EEG...
An electrically-powered device assembly designed to continuously measure the electrical signals produced by a patient's brain and display/record them as an electroencephalogram (EEG) to evaluate brain function, typically in an examination room or intensive ...
A mains electricity (AC-powered) bedside device designed to continuously assess the adequacy of the nerve function of a non-ambulatory patient who requires monitoring (e.g., as a result of trauma, anaesthesia, intervention, evaluation). It typically monitor...
A mains electricity (AC-powered) device assembly designed to continuously measure the electrical signals produced by a patient's brain and display/record them as an electroencephalogram (EEG) to evaluate brain function. It may be capable of monitoring vario...
A mains electricity (AC-powered) device assembly designed to continuously measure the electrical signals produced by a patient's brain and display/record them as an electroencephalogram (EEG) to evaluate brain function. It may be capable of monitoring vario...
A computerized device assembly designed for: 1) analysis of biomechanical/neuromuscular function using dedicated hardware; and 2) neuromuscular rehabilitation therapy at multiple anatomical sites based on patient interaction with dedicated physical-response...
An assembly of devices designed to continuously measure and wirelessly transmit electromyographic (EMG) signals from a patient to a receiving location (e.g., central station, bedside monitor) for viewing. It typically consists of a portable transmitter with...
A body-worn, battery-powered component of an electromyography telemetric monitoring system designed to continuously measure and wirelessly transmit electromyographic (EMG) signals to the system's receiver. The transmitter typically includes an antenna and a...
An electrically-powered unit intended to produce electrical signals for preoperative and/or intraoperative application of electrical stimulation, via a connected hand-held probe with distal electrodes (not included), to a neural tissue site to: 1) locate ne...