A device designed to facilitate insertion, positioning, and/or removal of a foetal scalp electrode. The applicator is typically a driving tubular device upon which the scalp electrode is positioned; the applicator is advanced against the scalp and the drive...
An electrical conductor intended to be used in pairs to transmit a controlled electrical shock from an external defibrillator to a post-pubescent patient in order to defibrillate the heart (restore a normal rhythm) or slow a rapid heart rate. It usually con...
An electrical conductor used in pairs to transmit a controlled electrical shock from an external defibrillator to a post-pubescent patient in order to defibrillate the heart (restore a normal rhythm) or slow a rapid heart rate. It usually consists of a cabl...
An electrical conductor used in pairs to transmit a controlled electrical shock from an external defibrillator to a pre-pubescent patient in order to defibrillate the heart (restore a normal rhythm) or slow a rapid heart rate. It usually consists of a cable...
An electrical conductor intended to be used in pairs to transmit a controlled electrical shock from an external defibrillator to a pre-pubescent patient in order to defibrillate the heart (restore a normal rhythm) or slow a rapid heart rate. It usually cons...
A sterile electrical conductor designed to transmit electric signals from the foetal scalp to an intrapartum monitor. The device is a spiralled (either single- or double-helix) metallic electrode with a sharp tip that is directly inserted into the foetal sc...
A sterile electrical conductor comprised of an electrode handpiece with cables and an active electrode, intended to be used to cut and coagulate tissue at a surgical site. The electrode is typically non-detachable and provides an electrical connection betwe...
A non-patient-contact, insulated, electrical cord with a connector (plug) at both ends designed to transmit electrical power and/or signal (data) between medical devices (e.g., to connect a lead, electrical catheter, handpiece, or monitor to a parent device...
A hollow, long, tubular electrical conductor with a sharply-pointed distal end intended for percutaneous introduction within soft tissue to deliver short electrical pulses, in a monopolar configuration, to produce irreversible cell membrane electroporation ...
A hollow, long, tubular electrical conductor with a sharply-pointed distal end intended for endoscopic introduction to deliver short electrical pulses, in a monopolar configuration, to produce irreversible cell membrane electroporation for ablation of soft ...
A collection of non-sterile, noninvasive devices intended to be used to conduct electrical signals from a patient's heart, via an electrode attached to the surface of the chest/limbs, to an electrocardiograph (ECG) machine or a patient monitoring system. It...
A collection of noninvasive devices intended to conduct electrical signals from a patient's heart, via an electrode attached to the surface of the chest/limbs, to an electrocardiograph (ECG) machine or a patient monitoring system. It is designed as an insul...
A collection of noninvasive devices intended to conduct electrical signals from a patient's heart, via an electrode attached to the surface of the chest/limbs, to an electrocardiograph (ECG) machine or a patient monitoring system. It is designed as an insul...
A sterile hand-held component of an electrosurgical system intended to provide an electrical connection between the system generator and a detachable electrode at its distal end, enabling the surgeon controlled manipulation of the electrode during surgery; ...
A hand-held component of an electrosurgical system intended to provide an electrical connection between the system generator and a detachable electrode at its distal end, enabling the surgeon controlled manipulation of the electrode during surgery; the elec...
A collection of non-sterile, noninvasive devices intended to be used to conduct electrical signals from a patient's heart, via an electrode attached to the surface of the chest/limbs, to an electrocardiograph (ECG) machine or a patient monitoring system. It...
A sterile electrical conductor designed to transmit electric signals from the foetal scalp to an intrapartum monitor. The device is a metallic clip electrode mounted on a small disk with a cable that may include a transducer. The clip is spring-loaded in a ...
A non-patient-contact, insulated, electrical cord with a connector (plug) at both ends designed to transmit electrical power and/or signal (data) between medical devices (e.g., to connect a lead, electrical catheter, handpiece, or monitor to a parent device...
A non-sterile, noninvasive electrical conductor designed to conduct electrical signals, generated by a patient's heart, from the skin surface to an electrocardiograph (ECG) monitoring device, via an ECG lead wire (not included). It is typically a disk-like ...
A sterile electrical conducting device designed to be inserted percutaneously into muscle or nerve tissue to detect bioelectrical signal activity. It is a needle-like device (a needle electrode with an electrical connector at the proximal end) that is conne...
A sterile electrical conductor comprised of an electrode handpiece with cables and an active electrode, typically non-detachable, intended to provide an electrical connection between the output terminals of an electrosurgical diathermy generator and a patie...
A flexible, invasive, endoscopic device intended to deliver both: 1) a submucosal lifting solution; and 2) an electrosurgical current in a monopolar configuration (i.e., with a return electrode) to tissues for cutting/coagulation. It is typically intended t...
An electrical conductor intended to be inserted percutaneously into interstitial tissue to continuously measure and record interstitial-fluid glucose concentrations, typically for detecting trends and tracking patterns in patients with diabetes mellitus. It...
A slender electrical conductor with a connection cable intended to be inserted within the lumen of an irreversible electroporation system percutaneous probe to deliver short electrical pulses, in a monopolar configuration, from a system generator to the pro...
An array of analytical scalp electrodes preconfigured within a head-worn device designed for the rapid placement and appropriate positioning of the scalp electrodes during electroencephalography (EEG). It typically consists of a cap-like device with integra...
A non-sterile dispersive conductor intended to be fastened to a patient and connected to an electrosurgical/radio-frequency ablation system generator, to allow return of electrical current from the patient to the generator during an electrosurgical procedur...
A sterile dispersive conductor intended to be fastened to a patient and connected to an electrosurgical/radio-frequency ablation system generator, to allow return of electrical current from the patient to the generator during an electrosurgical procedure. I...
An electrical conductor used in pairs to transmit a controlled electrical shock from an external defibrillator to a post-pubescent patient in order to defibrillate the heart (restore a normal rhythm) or slow a rapid heart rate. It typically consists of a ca...
An electrical conductor intended to be used in pairs to transmit a controlled electrical shock from an external defibrillator to a post-pubescent patient to defibrillate the heart (restore normal rhythm) or slow a rapid heart rate. It typically consists of ...
An electrical conductor used in pairs to transmit a controlled electrical shock from an external defibrillator to a pre-pubescent patient in order to defibrillate the heart (restore a normal rhythm) or slow a rapid heart rate. It typically consists of a cab...