A device intended to be placed within a breathing circuit proximal to the patient, to remove and retain microbes whilst capturing the patient's exhaled heat and moisture so that they can be used to heat and humidify the therapeutic gases inspired by the pat...
A one-piece, canister-like device that connects in-line with a patient's artificial airway [e.g., an endotracheal (ET) tube], to capture the patient's exhaled heat and moisture so that they can be used to heat and humidify therapeutic gases inspired by the ...
"A one-piece, canister-like device that connects in-line with a patient's artificial airway [e.g., an endotracheal (ET) tube], to capture the patient's exhaled heat and moisture so that they can be used to heat and humidify therapeutic gases inspired by the...
A non-sterile device intended to be placed within a breathing circuit proximal to the patient, to remove and retain microbes whilst capturing the patient's exhaled heat and moisture so that they can be used to heat and humidify the therapeutic gases inspire...
A dedicated membrane that is inserted into a reusable heat & moisture exchanger (HME) to capture a patient's exhaled heat and moisture, so that they can be used to heat and humidify therapeutic gases inspired by the patient typically during anaesthesia or i...
A sterile device intended to be placed within a breathing circuit proximal to the patient, to remove and retain microbes whilst capturing the patient's exhaled heat and moisture so that they can be used to heat and humidify the therapeutic gases inspired by...
A canister-like device that, when used together with a dedicated humidifying insertable filter, connects in-line with a patient's artificial airway [e.g., an endotracheal (ET) tube] to capture the patient's exhaled heat and moisture so that they can be used...
A collection of noninvasive devices intended to conduct fluids from an intravenous (IV) administration bag/bottle to a peripheral venous cannula (not included) during gravitational or pump administration to a patient's venous system; some types may in addit...
A collection of noninvasive devices designed to conduct fluids from an intravenous (IV) administration bag/bottle to a peripheral venous cannula (not included) during gravitational or pump administration to a patient's venous system; some types may in addit...
A device designed for the extracorporeal diffusion of oxygen into blood across a gas-permeable membrane during a cardiopulmonary bypass or extracorporeal membrane oxygenation procedure. It includes a membrane that separates a thin layer of blood from the ox...
An assembly of devices that provides mechanical circulatory support during open-heart surgery, bypassing the heart to facilitate surgery on the organ. The basic function of the machine is to oxygenate the body's venous supply of blood and then pump it back ...
A non-sterile component of a circulating-fluid thermal/compression therapy system intended to facilitate, through thermal therapy (heating and/or cooling) and compression, the treatment of a variety of adverse conditions resulting from a musculoskeletal inj...
A mains electricity (AC-powered) device, which may include rechargeable batteries, designed for in-line heating of banked blood, blood products, intravenous (IV) solutions, and irrigation fluids, typically from about 4ºC to near body temperature (i.e., 35 t...
A collection of devices intended to be used to infuse cardioplegia solution into the heart to interrupt its contractions during cardiopulmonary bypass surgery. It typically consists of tubing/adaptor, a filter, and a heat exchanger. This is single-use device.
A non-sterile device designed as a filter for protecting a stomal opening in the windpipe (surgically-created artificial opening between the trachea and the body surface through which the patient can breathe) against harmful external influences. It may also...
A collection of sterile devices intended to be used to inject cardioplegia solution into the heart to interrupt its contractions during cardiopulmonary bypass surgery. It typically consists of tubing/adaptor, a filter, and a heat exchanger. This is single-u...
An electrically-powered device designed for in-line heating of banked blood, blood products, intravenous (IV) solutions, and irrigation fluids, typically from about 4ºC to near body temperature (i.e., 35 to 37ºC) before infusion, through the conduction of h...
A device consisting of a heat exchanging system intended to be used in extracorporeal circulation to warm or cool the blood or perfusion fluid flowing through the device for the purposes of cardiopulmonary bypass intervention or treatment. This device will ...
A mains electricity (AC-powered) component of a cardiopulmonary bypass system designed to heat or cool a patient's body by extracorporeal heat exchange with the patient's perfused blood during a cardiopulmonary bypass procedure. It consists of a system to h...
A device consisting of a heat exchanging system intended to be used in extracorporeal circulation to warm or cool the blood or perfusion fluid flowing through the device for the purposes of cardiopulmonary bypass intervention or treatment. This device will ...
A non-sterile component of a circulating-fluid localized thermal/compression therapy system intended to facilitate, through thermal therapy (heating and/or cooling) and compression, the treatment of a variety of adverse conditions resulting from a musculosk...
An assembly of devices that provides mechanical circulatory support during open-heart surgery, bypassing the heart to facilitate surgery on the organ. The basic function of the machine is to oxygenate the body's venous supply of blood and then pump it back ...
A collection of devices intended to be used in conjunction with a non-surgically invasive ultrasound transducer (probe) (e.g., of a therapeutic oncological/gynaecological ultrasound system) to cool the transducer and improve coupling. It typically consists ...
An assembly of devices designed to provide partial extracorporeal respiratory support to treat acute hypercapnic respiratory failure in settings where the patient may be moved while on therapy [e.g., intensive care unit (ICU), emergency room]. It is intende...
An electrically-powered device designed for in-line heating of banked blood, blood products, intravenous (IV) solutions, and irrigation fluids, typically from about 4ºC to near body temperature (i.e., 35 to 37ºC) before infusion, through the convection of h...
A collection of sterile devices designed to be used in the function of an automated peritoneal lavage system (APLS). It typically includes tubing to connect the infusion/extraction pump mechanism of the control unit and the other components of the system [a...
A mains electricity (AC-powered) device designed for in-line heating of rapidly-infused (may exceed 1 L/min) banked blood, blood products, and intravenous (IV) solutions (crystalloid and colloid), typically from about 4?C to near body temperature (i.e., 35 ...
An electronic device that is a module of a cardiopulmonary bypass system and that is used to measure and display the temperatures of the different temperature probes that are connected into the total system in order to monitor the fluid and blood temperatur...
A noninvasive device intended to be used in the home and clinical settings by a person breathing through a tracheostoma to facilitate the connection of a device at the tracheostoma, on the skin side [e.g., heat and moisture exchanger (HME), oxygen administr...
A device intended to facilitate the connection of another device [e.g., hands-free speech valve, heat and moisture exchanger (HME)] to a tracheostomy tube on the tracheostoma skin side. It is typically made of synthetic polymer materials and in the form of ...