A multi-purpose flexible tube with an inflatable balloon at the distal end designed to be introduced into either the gastrointestinal ductal system (i.e., the pancreatic, hepatic, and/or common bile ducts) or tracheobronchial tree (i.e., capable of both) fo...
A flexible, invasive, endoscopic device assembly intended to deliver: 1) a submucosal lifting solution; 2) an electrosurgical current in a bipolar configuration to tissues for cutting; and 3) microwave energy to tissues for coagulation. It is typically inte...
A flexible, invasive, endoscopic device assembly intended to deliver: 1) a submucosal lifting solution; 2) an electrosurgical current in a bipolar configuration to tissues for cutting; and 3) microwave energy to tissues for coagulation. It is typically inte...
A flexible tube designed to be introduced into the tracheobronchial tree for the injection of contrast medium. It typically consists of a single lumen and an irrigation port, and is introduced via the oral cavity with a flexible endoscope. This is a reusabl...
An impervious, flexible, sterile container intended to be used during minimally-invasive, typically keyhole, surgical techniques (e.g., laparoscopic) to extract dissected patient body tissue. The device is inserted into the body through a large bore cannula...
A sterile, flexible tube intended to be surgically inserted through the skull for long-term (> 30 days) subdural access to the brain (e.g., cerebral ventricles, cystic tumours) for cerebrospinal fluid (CSF) drainage and/or infusion of materials (e.g., chemo...
A device designed to connect a respiratory circuit (e.g., an anaesthesia breathing circuit or ventilator breathing circuit) or a resuscitator to an endotracheal (ET) tube, to enable increased mobility at the patient end of the circuit or connections. It mos...
A flexible tube with an inflatable balloon at its distal tip designed to be introduced percutaneously into the venous system via a central vein and advanced to the pulmonary artery, to measure/monitor haematological parameters (e.g., pulmonary arterial pres...
A flexible tube with a sensor at the distal end intended to be surgically inserted through the skull for short-term (= 30 days) access to the ventricular and/or parenchymal areas of the brain to measure intracranial parameters [e.g., intracranial pressure (...
A device designed to connect a respiratory circuit (e.g., an anaesthesia breathing circuit or ventilator breathing circuit) or a resuscitator to an endotracheal (ET) tube, to enable increased mobility at the patient end of the circuit or connections. It mos...
A sterile flexible tube intended to be surgically inserted through the skull for short-term (= 30 days) subdural access to the brain (e.g., cerebral ventricles, cystic tumours) for cerebrospinal fluid (CSF) drainage and/or infusion of materials (e.g., chemo...
A long flexible or rigid tube with an atraumatic tip intended to be used during an endoscopic/laparoscopic procedure to provide access for the administration of a haematological concentrate and/or haemostatic agent (e.g., thrombin, platelet concentrate, pol...
A flexible tube intended to be surgically inserted through the skull for short-term (= 30 days) subdural access to the brain (e.g., cerebral ventricles, cystic tumours) for cerebrospinal fluid (CSF) drainage and/or infusion of materials (e.g., chemotherapeu...
A device used to connect a respiratory circuit (e.g., an anaesthesia breathing circuit or ventilator breathing circuit) or a resuscitator to an endotracheal (ET) tube, to enable increased mobility at the patient end of the circuit or connections. It most co...
A sterile flexible tube with a sensor at the distal end intended to be surgically inserted through the skull for short-term (= 30 days) access to the ventricular and/or parenchymal areas of the brain to drain cerebrospinal fluid (CSF) and to measure intracr...
A flexible tube with an inflatable balloon at its distal tip designed to be introduced percutaneously into the venous system via a central vein and advanced to the pulmonary artery, to measure/monitor haematological parameters (e.g., pulmonary arterial pres...
A flexible tube with a sensor at the distal end intended to be surgically inserted through the skull for short-term (= 30 days) access to the ventricular and/or parenchymal areas of the brain to measure intracranial parameters [e.g., intracranial pressure (...
A flexible, hollow cylinder with an inflatable balloon(s) and aspiration port(s) intended to be non-surgically inserted into the oesophagus and stomach, through the nose or mouth, to tampon bleeding oesophageal varices. The device is also known as a Sengsta...
A device designed to connect a respiratory circuit (e.g., an anaesthesia breathing circuit or ventilator breathing circuit) or a resuscitator to an endotracheal (ET) tube, to enable increased mobility at the patient end of the circuit or connections. It mos...
A long, thin flexible tube containing retractable forceps (grasping arms) intended to be inserted into the vasculature (artery/vein) to manually grasp and remove unintentionally-introduced foreign bodies (e.g., sheared cannula tips). Its use is typically in...
A flexible tube with an inflatable balloon at its distal tip designed to deliver an indicator solution (e.g., saline or dextrose), at a temperature lower than the blood in the heart, to measure and monitor cardiac output and other haemodynamic parameters us...
A flexible tube or shaft with an inflatable balloon(s) at its distal end intended for percutaneous introduction to dilate and stabilize within the aorta a previously deployed aortic endovascular implant (e.g., stent-graft) [not included]; it is not intended...
A sterile, thin, flexible, hollow tube intended to be percutaneously implanted by endoscopic methods into the stomach of a morbidly obese (bariatric) patient (= 18 years) for the removal of a portion of stomach contents after meals by aspiration when used w...
A long flexible or rigid tube with an atraumatic tip intended to be used during an endoscopic/laparoscopic procedure to provide access for the administration of a haematological concentrate and/or haemostatic agent (e.g., thrombin, platelet concentrate, pol...
A long flexible or rigid tube with an atraumatic tip intended to be used during an endoscopic/laparoscopic procedure to provide access for the administration of a haematological concentrate and/or haemostatic agent (e.g., thrombin, platelet concentrate, pol...
A long flexible or rigid tube with an atraumatic tip intended to be used during an endoscopic/laparoscopic procedure to provide access for the administration of a haematological concentrate and/or haemostatic agent (e.g., thrombin, platelet concentrate, pol...
A flexible, invasive, hand-held endoscopic device assembly intended to deliver microwave energy to tissues for coagulation, whilst allowing injection of a solution (e.g., vasoconstrictive agents) primarily to help control/stop serious bleeds (haemostasis) d...
A device used to connect a respiratory circuit (e.g., an anaesthesia breathing circuit or ventilator breathing circuit) or a resuscitator to an endotracheal (ET) tube, to enable increased mobility at the patient end of the circuit or connections. It most co...
A long, thin, flexible tube with one or more inflatable balloons at its distal tip designed to be introduced through the working channel of a gastroscope to access the small intestines (duodenum or jejunum) to administer fluids used for enteroclysis procedu...