A dedicated, partially-threaded rod intended to be implanted through the sleeve of a femoral neck fixation plate/sleeve (not included) and into the neck and head of the femur to treat a trochanteric fracture. It is commonly referred to as a dynamic hip scre...
An implantable, non-bioabsorbable, non-customized sheet of firm material that incorporates a sleeve (commonly known as a barrel) at its proximal end designed to be attached with screws to the proximal femur to treat a femoral neck (trochanteric) fracture. T...
A sterile implantable device typically designed to be attached to a revision femoral stem, knee femur prosthesis, femur/tibia shaft prosthesis, or body femoral/tibial extension stem to extend length to make up for bone loss during revision arthroplasty or b...
A sterile implantable device designed to replace the proximal femoral neck during replacement of a total hip prosthesis typically due to wear. The device is composed of two or more separate segments designed to be joined (modular), is made of metal [e.g., c...
An implantable partial substitute for a disease-damaged hip joint intended to replace the articulating surfaces of the hip while preserving the natural femoral head and neck. It consists of a metallic femoral cap component, that is placed over (resurfaces) ...
A sterile implantable device typically designed to be attached to a revision femoral stem prosthesis, knee femur prosthesis, femur/tibia shaft prosthesis, or body femoral/tibial extension stem to extend length to compensate for bone loss during revision art...
An implantable, metallic, partial substitute for a disease-damaged hip joint intended to replace the articulating surface of the femoral head while preserving the natural femoral head and neck. Fixation devices for implantation (e.g., screws/bolts) may be i...
A surgical instrument designed to help remove the natural femoral head from within the acetabulum during a total hip replacement procedure. It is typically a one-piece instrument with a long slender shaft of various distal-end designs (e.g., screw, fork) in...
A component of a multi-device tool designed for compression of a femoral neck fracture during the implantation of a fixation femoral neck, head nail, and/or screw. It consists of one of a variety of devices: a double threaded wire, a tubular housing instrum...
A sterile implantable principal component of a total hip prosthesis (femoral component) designed to replace the femoral head and neck; the device is composed of two or more separate pieces (e.g., head, neck, and stem) designed to be joined and is coated wit...
A sterile implantable device designed to replace the proximal femoral neck as part of a total hip arthroplasty (THA). The device is composed of two or more separate segments designed to be joined, typically made of metal [e.g., cobalt-chrome (Co-Cr), titani...
A sterile artificial substitute for the bearing surface of only one femoral condyle and corresponding tibial condyle of the knee (medial or lateral condyle) implanted during primary or revision knee replacement. It typically consists of femoral and tibial c...
A sterile implantable principal component of a total hip prosthesis (femoral component) designed to replace the femoral head and neck. The device is composed of two or more separate pieces (e.g., head, neck, and stem) designed to be joined, and is contoured...
A sterile implantable principal component of a total hip prosthesis (femoral component) designed to replace the femoral head and neck. The device is one-piece and is contoured to enable fixation by pressing the distal end into the cortex of the remaining na...
A sterile device designed to replace the entire femoral component of a total hip prosthesis implanted during replacement of the total hip prosthesis typically due to wear. The revision device is composed of two or more separate segments (e.g., femoral head,...
A sterile implantable principal component of a total hip prosthesis (femoral component) typically designed to replace the femoral head and neck; the device is composed of two or more separate pieces (e.g., head, neck, and stem) designed to be joined and is ...
A sterile implantable device designed to replace the proximal femoral neck as part of a total hip arthroplasty (THA). The device is one-piece, is made of metal [e.g., cobalt-chrome (Co-Cr), titanium (Ti), stainless steel], and is not coated with materials i...
A sterile device designed to replace the entire femoral component of a total hip prosthesis implanted during replacement of the total hip prosthesis typically due to wear. The revision device is composed of two or more separate segments (e.g., femoral head,...
A sterile implantable principal component of a total hip prosthesis (femoral component) designed to replace the femoral head and neck; the device is one-piece and is not coated with materials intended to improve fixation and stability. The device may be mad...
A sterile implantable device intended to provide an extension of, or coupling with, other components of a modular femoral/tibial prosthesis in the medullary canal to compensate for bone loss during revision arthroplasty or bone resection. The device is a so...
A sterile implantable device designed to replace the proximal femoral neck as part of a total hip arthroplasty (THA). The device is one-piece, is made of metal [e.g., cobalt-chrome (Co-Cr), titanium (Ti), stainless steel], and is coated with a material (e.g...
A sterile implantable device designed to replace the proximal femoral neck as part of a total hip arthroplasty (THA). The device is composed of two or more separate segments designed to be joined, is made of metal [e.g., cobalt-chrome (Co-Cr), titanium (Ti)...
A collection of non-sterile devices intended for use with a knee arthroplasty force sensor to measure forces acting across the joint to facilitate assessment of bone resection lines and size of prosthesis components to be implanted. It is intended to help a...
A sterile implantable device intended to provide an extension of, or coupling with, other components of a modular femoral/tibial prosthesis in the medullary canal to compensate for bone loss during revision arthroplasty or bone resection. The device is a so...
An implantable, non-customized sheet of firm material that incorporates a blade at one end designed to be attached with screws to the proximal and/or distal femur to treat a fracture; the blade is intended to be introduced into the bone to assist with fixat...
A small implantable surgical device designed to join (connect) two components of an implanted orthopaedic fixation device (e.g. osteotomy wedge to plate, femoral neck screw and plate); it is not intended to be screwed into the bone. It is typically made of ...
A small implantable surgical device designed to join (connect) two components of an implanted orthopaedic and/or craniofacial device (e.g. osteotomy wedge to plate, femoral neck screw and plate); it is not intended to be screwed into the bone. It is typical...
A small implantable surgical device designed to join (connect) two components of an implanted orthopaedic fixation device (e.g. osteotomy wedge to plate, femoral neck screw and plate). It is typically made of metal and in the form of a short rod with machin...
A small, threaded, non-bioabsorbable, implantable rod intended for internal orthopaedic fixation by being screwed into a limb bone, rib, the sternum and/or pelvis to hold a plate, nail, rod or prosthesis to the bone, or to provide direct interfragmentary st...
A small, threaded, non-bioabsorbable, implantable rod intended to be used for internal orthopaedic fixation by being screwed into a limb bone, rib, the sternum and/or pelvis to hold a plate, nail, rod or prosthesis to the bone, or to provide direct interfra...