A switching component of a surgical microscope video camera intended to facilitate either the application of a single light wavelength filter or the changing from one filter to another. The filters are incorporated within the main microscope assembly and ar...
121 GUDID devices
A mobile, mains electricity (AC-powered) device assembly designed to collect surgical fluid waste and plume smoke generated by surgical procedures involving electrosurgical diathermy, electrocautery, or a laser. It typically consists of a suction pump, tubi...
115 GUDID devices
An assembly of devices designed to evacuate fluid, tissue, gas, or other foreign materials from a body cavity or lumen by means of suction. It generally consists of a mains electricity (AC-powered) suction pump, tubing, plastic/glass collection container(s)...
38 GUDID devices
An assembly of devices designed to evacuate fluid, tissue, gas, or other foreign materials from a body cavity or lumen by means of suction. It generally consists of a suction pump powered by compressed air or oxygen from a hospital's central gas system, tub...
21 GUDID devices
An assembly of devices designed to evacuate large volumes of fluid and/or air accumulated between the lung and chest wall (pleural space) by means of suction. It generally consists of a mains electricity (AC-powered) suction pump, tubing, plastic/glass coll...
7 GUDID devices
An assembly of devices designed for use with an intracorporeal lithotripsy system to evacuate, by suction, the irrigation fluid-containing fragments of urinary calculi from the kidneys, ureters, and bladder during lithotripsy. It typically consists of a pne...
2 GUDID devices
A sterile implantable device intended to be used with a cerebrospinal fluid (CSF) shunt assembly (e.g., ventriculoperitoneal shunt, lumboperitoneal shunt) for in-line shunt placement to filter particles by size to prevent transmission of cells when draining...
1 GUDID devices
A device used with a diagnostic or therapeutic x-ray system consisting of single/compound metal composition sheets that are designed to be placed in the path of the x-ray beam before it reaches the patient (target). It is typically made of aluminium, copper...
18 GUDID devices
A device that is a module to an anaesthesia workstation and functions as a mounting system used to attach compressed gas cylinders to the anaesthesia system. The yoke assembly typically includes a filter, pressure regulator, pressure relief valve, and press...
6 GUDID devices
An assembly of devices intended to provide cerebrovascular embolic protection during carotid artery angioplasty and stenting procedures. It is available in various configurations and typically includes a sheath/catheter(s), intravascular balloon(s), guidewi...
310 GUDID devices
An assembly of devices that provides continuous and/or intermittent percutaneous infusion of a prescribed medicated solution to a patient through forces from elastic material. It typically consists of an elastomeric chamber (various sizes predetermine the f...
274 GUDID devices
A mains electricity (AC-powered) assembly of devices intended to capture smoke generated during open surgical procedures involving tissue ablation (e.g., laser surgery, electrocautery, electrosurgical diathermy device). It captures the plume (smoke composed...
242 GUDID devices
An assembly of devices designed to evacuate fluid, tissue, gas, or foreign materials from a body cavity or lumen by means of suction. It is connected via dedicated vacuum tubing to the vacuum terminal unit (wall outlet) of a vacuum pipeline system and power...
241 GUDID devices
An assembly of devices that provides mechanical circulatory support during open-heart surgery, bypassing the heart to facilitate surgery on the organ. The basic function of the machine is to oxygenate the body's venous supply of blood and then pump it back ...
214 GUDID devices
A portable assembly of devices, which includes a non-surgical invasive component, intended to manually aspirate unwanted materials (e.g., fluids, secretions) from the airway typically during patient transport or an emergency situation (e.g., placed on a cra...
207 GUDID devices
An assembly of devices designed specifically to aspirate subcutaneous fat from the body by means of suction during a liposuction/lipectomy procedure. The system consists of an electrically-powered suction pump, typically with collection containers, tubing, ...
134 GUDID devices
An assembly of devices designed to evacuate large volumes of gas, liquid, tissue and/or other debris from a surgical site by means of suction during surgical procedures. It generally consists of a mains electricity (AC-powered) suction pump, a regulator and...
132 GUDID devices
An assembly of vacuum-powered devices, which includes a surgically invasive component, designed to aspirate unwanted materials (e.g., debris, tissues, fluids) from body cavities/wounds during a surgical procedure (e.g., general surgery, laparoscopy); it may...
98 GUDID devices
An assembly of mains electricity (AC-powered) devices intended to be used to perform patient haemodialysis, a treatment whereby extracorporeal blood is passed through a filter to allow for the removal of toxins and/or the replacement of electrolytes, by tra...
96 GUDID devices
A portable assembly of devices, which includes a non-surgical invasive component, intended to aspirate unwanted materials (e.g., fluids, secretions) from the airway typically during patient transport or an emergency situation (e.g., placed on a crash cart),...
80 GUDID devices
A portable assembly of devices, which includes a non-surgical invasive component, intended to aspirate unwanted materials (e.g., fluids, secretions) from the airway typically during patient transport or an emergency situation (e.g., placed on a crash cart)....
53 GUDID devices
An assembly of devices designed to collect and dispose of both surgical fluid waste and plume smoke generated by surgical procedures involving electrosurgical diathermy, electrocautery, or a laser. It typically consists of a mains electricity (AC-powered) m...
40 GUDID devices
An assembly of devices used to collect, filter, and reinfuse intraoperative and/or postoperative autologous blood shed during and/or after elective and non-elective surgery. It is a complete, closed-circuit system that typically includes a suction set or a ...
36 GUDID devices
An assembly of devices designed to collect the dust produced by a cast cutter (e.g., pneumatic or electric cast saw) from the workspace environment by suction during the cast removal procedure. It typically consists of a motorized vacuum pump, a filter, and...
36 GUDID devices
An assembly of devices designed to generate a low vacuum [typically
34 GUDID devices
An assembly of devices used to collect, filter, and reinfuse intraoperative and/or postoperative autologous blood shed during and/or after elective and non-elective surgery. It is a complete, closed-circuit system that typically includes a suction set or a ...
29 GUDID devices
An assembly of mains electricity (AC-powered) devices designed to perform haemodialysis, a treatment whereby extracorporeal blood is passed through a filter to allow for the removal of toxins and/or the replacement of electrolytes. The system functions with...
23 GUDID devices
A non-sterile, mains electricity (AC-powered) device assembly designed for viewing intraoperative blood flow in the cerebral vascular area, in bypass grafts during coronary artery bypass graft (CABG) surgery, and during plastic and reconstructive surgery. I...
20 GUDID devices
An assembly of sterile devices intended to be used to collect whole blood from a donor. It includes a container (a single flexible bag) with anticoagulation solution, tubing, and an attached needle for venipuncture. It may include integrated features such a...
16 GUDID devices
An assembly of devices which is a component of an x-ray/CT (computed tomography) system used in diagnostic x-ray applications for the delivery (by inhalation or injection) of xenon gas during real-time imaging studies of blood flow or other physical or phys...