A sterile shield, typically made of plastic in the form of a bag, placed over a foot-switch to protect the foot-switch from contamination, and to prevent potential cross-contamination between users. When used in the operating room (OR) it will provide the a...
An electrically-powered device intended to be used as an interface between an electrical foot-switch and an electrosurgical system generator, to convert analogue electrical signals from the foot-switch into a digital form that the generator can interpret as...
A multi-purpose assembly of devices designed to power and control the mechanical mechanism of an atherectomy catheter and, alternatively, a thrombectomy catheter during an intravascular recanalization procedure. It typically consists of a mains electricity ...
A multi-purpose assembly of devices designed to power and control the mechanical mechanism of an atherectomy and/or thrombectomy catheter (not included) during an intravascular recanalization procedure. It typically consists of an electrically-powered contr...
A sterile electrical conductor comprised of an electrode handpiece with cables and an active electrode, typically non-detachable, intended to provide an electrical connection between the output terminals of an electrosurgical diathermy generator and a patie...
An assembly of mains electricity (AC-powered) devices intended to apply ultrasonic oscillations to: 1) mechanically fragment and dislodge gross debris in the dental pulp canal during an endodontic procedure; and/or 2) remove accretions from tooth surfaces d...
An electrically-powered pedal used by an operator of a medical device to regulate the activation and/or intensity of a parent device (e.g., electrosurgical system generator, laser, ophthalmic examination unit, dental drill/saw system control unit) to which ...
A mains electricity (AC-powered) device assembly in which input energy (e.g., flashlamp, diode laser) is used to excite a glass/crystal rod, or a fibre doped with a glass/crystal element (known as fibre laser), to emit a high-power laser beam intended to in...
A mains electricity (AC-powered) device assembly in which input energy (e.g., flashlamp, diode laser) is used to excite a glass/crystal rod to emit a high-power laser beam intended for general surgery and/or multiple specialized surgical applications (non-d...
A device designed to be attached to a suction system to control the degree of negative pressure (suction) applied in the evacuation of fluids, solids, or gases from the body during a neurosurgical procedure where the precise level of suction can be critical...
A mains electricity (AC-powered) device assembly in which input energy is used to excite a diode to emit a high-power therapeutic laser beam intended to cut, excise, vaporize, and coagulate oral tissues in various dental applications such as oral soft-tissu...
A mains electricity (AC-powered) device assembly in which input energy (e.g., flashlamp, diode laser) is used to excite a glass/crystal rod to emit a high-power laser beam intended for application in dental procedures; it does not include frequency-doubling...
A mains electricity (AC-powered) device assembly in which input energy (e.g., flashlamp, diode laser) is used to excite a glass/crystal rod to emit a high-power laser beam, in which the frequency is doubled, intended to precisely cut, excise/vaporize, and c...
A mains electricity (AC-powered) device assembly designed to produce two distinct high-power laser beams, one solid-state [e.g., neodymium-doped yttrium-aluminium-garnet (Nd:YAG)] mediated and the other carbon dixoide (CO2) mediated, intended for bloodless ...
A hand-held, line-powered device (which may in addition include a rechargeable battery) that consists of a motorized saw handpiece intended to provide sagittal, oscillating, or reciprocating movement for attachable serrated blades designed to cut through ha...
A hand-held, pneumatically-powered component of a surgical power tool assembly designed to convert the energy from a compressed gas source [e.g., surgical-grade air or nitrogen (N2)] into a non-dedicated mechanical energy for drilling or sawing during denta...
An assembly of devices that comprises a dental abrasive air jet system used to direct a concentrated jet of air combined with an abrasive powder, together with water for cooling, to the surface of the patient's tooth/teeth. It typically consists of a contro...
A mains electricity (AC-powered) device assembly in which input energy (e.g., flashlamp, diode laser) is used to excite a glass/crystal rod to emit a high-power laser beam intended to cut, excise, ablate, and vaporize soft tissues in dermatological applicat...
A mains electricity (AC-powered) device assembly in which input energy is used to excite a diode to emit a high-power therapeutic laser beam intended to cut, excise, vaporize, and coagulate tissues for general surgery and/or multiple specialized surgical ap...
An assembly of devices that converts high frequency current into ultrasonic oscillation to mechanically fragment soft-tissue cells upon contact with a vibrating tip for cutting and/or coagulating tissue during surgery, possibly in combination with irrigatio...
An assembly of devices that converts high frequency current into ultrasonic oscillation to mechanically fragment and cut bone upon contact with a vibrating tip during dental surgery, typically in combination with irrigation. It typically includes an energy-...
A hand-held, electrically-powered component of a dental power tool assembly designed to convert electrical energy into a non-dedicated mechanical energy for drilling or sawing during dental surgery. It is designed to accept handpiece components/attachments ...
A mains electricity (AC-powered) device assembly in which input energy is used to excite carbon dioxide (CO2) to emit a high-power laser beam, intended to incise, excise, ablate, and vaporize soft tissues for dermatological applications such as skin resurfa...
An assembly of devices used to mechanically cut (slice), core (cut a hole into), peel (remove surface), and extract selected tissue from the body (a process known as morcellation), typically during laparoscopic surgery (e.g., for tumour or fibroid removal)....
An electrically-powered device assembly in which input energy is used to excite a diode to emit a high-power therapeutic laser beam intended to cut, excise, vaporize, and coagulate tissues for general surgery and/or multiple specialized surgical application...
An electrically-powered component of an ultrasonic surgical system intended to generate a high frequency electrical current that is converted, typically within a handpiece, into an ultrasonic oscillation to fragment hard and/or soft tissue cells upon contac...
A mains electricity (AC-powered) device assembly in which input energy is used to excite a diode to emit a high-power therapeutic laser beam intended to remove unwanted body hair (e.g., armpit, leg/arm, back, chest, bikini line, and face). It is intended to...
A compact line-powered engine (that may include a rechargeable battery) intended to convert electrical energy into a non-dedicated mechanical energy to perform a variety of surgical procedures that include drilling, sawing, and inserting involving bones and...