A frame-like assembly of surgical instruments/devices intended to be used to create a self-locking, self-retaining mechanism to temporarily part tissue (e.g., hold the edges of an incision open) to expose internal tissues or organs for access during open su...
A device intended to be affixed to a patient's skull to enable precise localization of an area within the brain targeted for radiosurgical procedures (e.g., radiation treatment of a brain tumour). It is typically an assembly that includes a head ring or a h...
A frame-like assembly of surgical instruments/devices intended to be used to create a self-locking, self-retaining mechanism dedicated to the temporary parting of brain tissue during neurosurgery. It includes a mounting frame, mountable retracting blades, a...
A frame-like assembly of surgical instruments/devices intended to be used to create a self-locking, self-retaining mechanism dedicated to the temporary parting of dorsal tissue to enable access for spinal surgery. It includes a mounting frame, with retracti...
A sterile, frame-like assembly of surgical instruments/devices intended to be used to create a self-locking, self-retaining mechanism to temporarily part tissue (e.g., hold the edges of an incision open) to expose internal tissues or organs for access durin...
An electrically-powered, body-weight unloading, gait rehabilitation device designed to assist a patient with a walking/balance disability (neurogenic, muscular, or osseous in origin) regain lost motor function, by enabling them to hang in a dedicated harnes...
A manually-operated, body-weight unloading, gait rehabilitation device designed to assist a patient with a walking/balance disability (neurogenic, muscular, or osseous in origin) regain lost motor function, by enabling them to hang in a dedicated harness in...
An electrically-powered, stationary (non-mobile) assembly of devices designed to enable one person to lift and move an incapacitated patient or a person with a disability safely and with minimal physical effort within an area limited by the lifting radius o...
A mains electricity (AC-powered), stationary assembly of devices designed to enable one person to lift and move an incapacitated patient or a person with a disability, of any size and weight, safely and with minimal physical effort within an area limited by...
An electrically-powered component of a diagnostic x-ray system intended to be placed on the floor to position and support a patient, an x-ray tube assembly, and an image receptor assembly (bucky) during a diagnostic x-ray procedure. It typically consists of...
A mobile assembly of battery-powered devices designed to assist a patient with a walking/balance disability (neurological, muscular, cardiovascular, or orthopaedic in origin) to regain lost motor function, by enabling the patient to walk over ground (i.e., ...
An assembly of non-sterile devices designed to stabilize fractured bones to promote treatment and healing. It typically consists of an external plastic and/or metallic fixator (a framework) and other external and/or implantable components such as clamps, ro...
An assembly of devices designed to stabilize fractured bones to promote treatment and healing. It typically consists of an external plastic and/or metallic fixator (a framework) and other external and/or implantable components such as clamps, rods, rings, p...
An assembly of devices that typically consists of a rigid frame, positioning and alignment components, workstation, and a calibrated guide mechanism for precisely positioning probes, other instruments, or implantable devices during neurosurgery. The system ...
An assembly of devices designed to stabilize fractured bones, other than those in the vertebral column, to promote treatment and healing. It typically consists of an external plastic and/or metallic fixator (a framework) and other external and/or implantabl...
An assembly of devices that typically consists of a rigid frame, positioning and alignment components, workstation, and a calibrated guide mechanism for precisely positioning probes, other instruments, or implantable devices during a surgical procedure of m...
An assembly of sterile devices designed to stabilize fractured bones of the lower limbs to promote treatment and healing. It typically consists of an external plastic and/or metallic fixator (a framework) and other external and/or implantable components suc...
An assembly of devices that typically consists of a rigid frame, positioning and alignment components, workstation, and a calibrated guide mechanism for precisely positioning probes, other instruments, or implantable devices during orthopaedic surgery. The ...
A electrically-powered assembly of devices designed to enable an incapacitated patient or a person with a disability to be lifted/moved (transferred) safely and with minimal physical effort within the confines of one floor of a building, typically an instit...
An electrically-powered, mobile assembly of devices designed to enable one person to lift and move an incapacitated patient or a person with a disability safely and with minimal physical effort. Also known as a patient hoist, it typically consists of a supp...
An electrically-powered assembly of devices that typically consists of a rigid frame, positioning and alignment components, workstation, and a calibrated guide mechanism for precisely positioning probes, other instruments, or implantable devices during a su...
A battery-powered, mobile assembly of devices designed to enable one person to lift and move an incapacitated patient or a person with a disability, of any size and weight, safely and with minimal physical effort. Also known as a patient hoist, it typically...
An assembly of custom-made and preformed devices such as metal bands, archwires, springs, screws, power arms and/or a base plate (framework), designed to be applied to the teeth to influence the shape and/or function of the stomatognathic system to correct ...
A mobile assembly of mains electricity (AC-powered) electronic and optical devices designed to receive and analyse patient magnetic resonance imaging (MRI) images and position landmarks manually or automatically on these images, then register the images by ...
An assembly of devices that typically consists of a rigid frame, positioning and alignment components, workstation, and a calibrated guide mechanism for precisely positioning probes, other instruments, or implantable devices during ear/nose/throat (ENT) sur...
An assembly of devices that typically consists of a rigid frame, positioning and alignment components, workstation, and a calibrated guide mechanism for precisely positioning probes, other instruments, or implantable devices during dental surgery. The syste...
An electrically-powered component of a modular electromechanical operating table assembly designed as a height-adjustable support intended for the introduction and engagement of interchangeable operating table tops. It may be mobile or stationary and in the...
A non-powered, mobile assembly of devices designed to enable one person to lift and move an incapacitated patient or a person with a disability safely and with minimal physical effort. Also known as a patient hoist, it typically consists of a support base o...
A mobile assembly of devices designed to enable one person to lift and move an incapacitated patient or a person with a disability, of any size and weight, safely and with minimal physical effort. Also known as a patient hoist, it typically consists of a su...
An assembly of devices intended to be used during aortic valve replacement via aortotomy to facilitate temporary stabilization of the aortic root for improved aortic valve site exposure, visualization and tissue tension. It consists of a circular frame that...