A handle-like device that is attached (clips or is slid onto the cylindrical barrel) to an electrically- or pneumatically-powered surgical power tool handpiece or motor of the micro types (a drill or a saw) so that the two devices interact to function as a ...
"A handle-like device that is attached (clips or is slid onto the cylindrical barrel) to an electrically- or pneumatically-powered surgical power tool handpiece or motor of the micro types (a drill or a saw) so that the two devices interact to function as a...
A non-patient-contact, electrical cord with a connector at both ends and a hand-switch designed to transmit electrical energy from a power supply (e.g., generator) to an electrical catheter (e.g., ultrasonic atherectomy system catheter), and activate/deacti...
A multi-purpose assembly of devices designed to power and control the mechanical mechanism of an atherectomy catheter and, alternatively, a thrombectomy catheter during an intravascular recanalization procedure. It typically consists of a mains electricity ...
A multi-purpose assembly of devices designed to power and control the mechanical mechanism of an atherectomy and/or thrombectomy catheter (not included) during an intravascular recanalization procedure. It typically consists of an electrically-powered contr...
An artificial substitute for a missing hand that may be attached to a natural arm or used as part of an upper-limb external prosthetic system, and is designed to replace the appearance and some of the function of the hand. The device moves as the result of ...
A hand-held, line-powered device (which may in addition include a rechargeable battery) that consists of a motorized saw handpiece intended to provide sagittal, oscillating, or reciprocating movement for attachable serrated blades designed to cut through ha...
A hand-held, pneumatically-powered component of a surgical power tool assembly designed to convert the energy from a compressed gas source [e.g., surgical-grade air or nitrogen (N2)] into a non-dedicated mechanical energy for drilling or sawing during denta...
A hand-held, electrically-powered component of a dental power tool assembly designed to convert electrical energy into a non-dedicated mechanical energy for drilling or sawing during dental surgery. It is designed to accept handpiece components/attachments ...
A hand-held, electrically-powered component of a surgical power tool assembly designed to convert electrical energy into a non-dedicated mechanical energy to perform a variety of non-dental surgical procedures such as drilling or sawing of bones and tough t...
A hand-held, electrically-powered component of a surgical power tool assembly designed to convert electrical energy into a non-dedicated mechanical energy to perform a variety of surgical procedures such as drilling or sawing of bones and tough tissues; it ...
A hand-held instrument used with a plasma surgical system control unit to coagulate, cut, and/or vaporize/ablate tissue during open and/or laparoscopic surgery. Inert argon (Ar) gas is excited (ionized) in the instrument by a series of internal bipolar elec...
A hand-held, pneumatically-powered component of a surgical power tool assembly designed to convert the energy from a compressed gas source [e.g., surgical-grade air or nitrogen (N2)] into a non-dedicated mechanical energy to perform a variety of non-dental ...
A hand-held, electrically-powered component of a surgical power tool assembly designed to convert electrical energy into a non-dedicated mechanical energy to perform a variety of non-dental surgical procedures such as drilling or sawing of bones and tough t...
An electronic hand-held device designed to help a patient with a disability control the operation of a proximal human interface device (HID) [e.g., computer, tablet, smartphone, assistive speech generator] through a wired or wireless connection (e.g., Bluet...
A hand-held, line-powered device (which may in addition include a rechargeable battery) that consists of a motorized saw handpiece intended to provide sagittal, oscillating, or reciprocating movement for attachable serrated blades designed to cut through ha...
A sterile hand-held instrument used with a neutral plasma surgical system control unit to coagulate, cut, and/or vaporize/ablate tissue during open and/or laparoscopic surgery. Inert argon (Ar) gas is excited (ionized) in the instrument by a series of inter...
A hand-held, pneumatically-powered component of a surgical power tool assembly designed to convert the energy from a compressed gas source [e.g., surgical-grade air or nitrogen (N2)] into a non-dedicated mechanical energy to perform a variety of non-dental ...
A noninvasive, non-powered, hand-held device intended to be connected to, and facilitate manipulation of, an appropriate cannula (not included) for suction/removal (aspiration) of debris from the ear canal during an ear/nose/throat (ENT) procedure; it is no...
A compact line-powered engine (that may include a rechargeable battery) intended to convert electrical energy into a non-dedicated mechanical energy to perform a variety of surgical procedures that include drilling, sawing, and inserting involving bones and...
A sterile, hand-held, pneumatically-powered device designed to hold and operate a compatible ophthalmic surgical instrument tip (e.g., scissors, forceps). It is typically in the form of a conventional handle with a connector that secures the inserted tip, a...
A compact engine that draws power from a rechargeable battery pack intended to convert electrical energy into a non-dedicated mechanical energy to perform a variety of surgical procedures that include drilling, sawing, and inserting involving bones and toug...
A hand-held component of a dental ultrasonic surgical system that typically converts high frequency electrical current from a generator into an ultrasonic oscillation, for a tip placed at its end to mechanically fragment and cut bone upon contact during den...
A mobile assembly of devices intended to treat a variety of skin conditions (e.g., acne scars, actinic keratosis, wrinkles, superficial skin lesions, warts) through controlled heating of the skin surface via application of nitrogen plasma. It consists of a ...
An assembly of mains electricity (AC-powered) devices designed to apply cold from a gaseous or liquid refrigerant (cryogen) [e.g., liquid nitrogen (LN2), nitrous oxide (N2O), carbon dioxide (CO2)] to a target tissue for its destruction and removal during an...
A mains electricity-powered (AC-powered) device designed to provide high frequency electrical current to power connected electrosurgical diathermy instruments (create heat within tissues) and ultrasonic surgical instruments (rapidly vibrate tissues), enabli...
A handpiece, which is part of an endodontic obturation system, intended to control through its hand-switch an electrical current from the generator to the tip of an attached dental instrument where it is converted to resistive heat used to test tooth respon...
A hand-operated, non-sterile, magnetic device designed to be used by a patient to switch an implanted stimulator (e.g., a neurostimulator that can be controlled by a strong external magnetic force) on and off. It typically consists of a small portable magne...
An electronic device intended to be used with an ultrasound (US) imaging system to enable the simultaneous connection of multiple hand-held US transducers so the user can conveniently switch between transducers as required. It is a unit with multiple transd...
An invasive, rigid, hand-held component of an inert gas-enhanced electrosurgical system intended to deliver electrosurgical current within a stream of inert gas [e.g., argon (Ar), helium (He)] directly to tissues for cutting/coagulation during open surgery....