1 GUDID devices
A component of a peritoneal dialysis connection kit intended to function as a casing for elements used in a routine connection/disconnection between a peritoneal catheter and a dialysate line. It is a portable, closable, rigid housing with user interface le...
565 GUDID devices
A metallic (e.g., steel, aluminium alloy) case that houses an x-ray tube to provide appropriate limits for x-ray leakage and adequate insulation to avoid electric risks during a diagnostic x-ray procedure. It includes sheet lead surrounds at appropriate loc...
364 GUDID devices
A sterile device designed to allow access to either the Y-site of an intravenous (IV) line or an injection adaptor on the infusion catheter. Typically, a needle located inside a plastic housing can be inserted into a standard septum and a Luer fitting locat...
48 GUDID devices
A housing for x-ray film specifically designed to be used in, and work as part of, an automated x-ray film changing system. The housing is intended to be loaded with x-ray film under appropriate darkroom conditions, and is then inserted into the loading mag...
20 GUDID devices
A sampling device intended to be used for extracting a blood specimen from a blood donor bag tubing segment for analysis and/or other investigation (e.g., blood grouping, cross matching). It typically consists of a needle surrounded by plastic housing desig...
5 GUDID devices
A collection of devices intended to conveniently provide some of the components necessary for the ambulatory administration of insulin to a patient with diabetes mellitus. It consists of a sterile needle/cannula within a housing, a skin-adhesive patch/holde...
1 GUDID devices
A standard, non-motorized, diagnostic x-ray beam-limiting device that has a fixed size opening. It attaches by means of a slot or base plate to a diagnostic x-ray system tube housing and is used to limit the effects of scattered radiation on image quality a...
2,917 GUDID devices
A sterile, invasive, distal component of an electrosurgical assembly intended to deliver electrosurgical current in a monopolar configuration (i.e., used with a patient contact return electrode) to tissues for cutting/coagulation/ablation during endoscopic ...
1,986 GUDID devices
An invasive, distal component of an electrosurgical assembly intended to deliver electrosurgical current in a monopolar configuration (i.e., used with a patient contact return electrode) to tissues for cutting/coagulation/ablation during endoscopic (e.g., l...
1,344 GUDID devices
An electrically-powered device designed to supply an electrical charge, via a direct/wired or wireless connection, to the battery of a noninvasive device to recharge it for operation; it is not intended to receive data from and transmit data to other device...
1,007 GUDID devices
An invasive, distal component of an electrosurgical assembly intended to deliver electrosurgical current in a bipolar configuration (i.e., without a return electrode) to tissues for cutting/coagulation/ablation during endoscopic (e.g., laparoscopic, arthros...
750 GUDID devices
A non-sterile, portable, screening device intended to be used during pulmonary function testing to remove and retain microdroplets from patient breath to reduce contamination of the parent device; it is also intended to function as a mouthpiece to facilitat...
705 GUDID devices
A screening device intended to remove microbes from medical gases to prevent patient exposure during respiration, anaesthesia and/or endoscopy; it has no additional non-filtering functions. It is a small plastic housing containing a filter which will typica...
596 GUDID devices
A device intended to be placed within a breathing circuit proximal to the patient, to remove and retain microbes whilst capturing the patient's exhaled heat and moisture so that they can be used to heat and humidify the therapeutic gases inspired by the pat...
349 GUDID devices
An invasive, distal component of an electrosurgical assembly intended to deliver electrosurgical current in a bipolar configuration (i.e., without a return electrode) to tissues for cutting/coagulation/ablation during endoscopic (including laparoscopic, art...
302 GUDID devices
A sterile metallic and/or non-metallic device intended to be implanted subcutaneously in a patient for the short- or long-term delivery of fluids or medications to the vascular system or other anatomical region. The device consists of a housing with a self-...
292 GUDID devices
A device intended to be fitted to a vial or bottle to enable the removal of its contents, (e.g., medication, nutritional solution for enteral feeding) into a syringe, for subsequent administration to a patient. It is typically a housing with a barbed connec...
262 GUDID devices
A non-sterile device intended to be placed within a breathing circuit proximal to the patient, to remove and retain microbes whilst capturing the patient's exhaled heat and moisture so that they can be used to heat and humidify the therapeutic gases inspire...
197 GUDID devices
A device intended to be fitted into an endodontic instrument holder housing and used chairside during a dental endodontic procedure to hold and temporarily store sharp endodontic instruments (e.g., files/rasps). It is in the form of a spongy foam insert int...
193 GUDID devices
A mechanical device designed to provide a visual indication of a patient's airway pressure during ventilation. It is typically contained in a clear housing marked with a pressure scale [e.g., 5 to 60 cm H20 (hPa)], and has a spring-loaded indicator that, in...
183 GUDID devices
A sterile artificial substitute for a natural aortic heart valve intended to be implanted during open heart surgery typically to treat acquired or congenital valvular disease. It consists of two flat, semicircular, pyrolytic carbon-coated or polymer leaflet...
182 GUDID devices
A cap/cover intended to be extended over a used needle (attached to a syringe/autoinjector or not) to prevent accidental needle sticks, typically during removal of the needle. It is typically a plastic housing with appropriate shielding to prevent injury up...
176 GUDID devices
A non-sterile screening device intended to remove microbes from medical gases to prevent patient exposure during respiration, anaesthesia and/or endoscopy; it has no additional non-filtering functions. It is a small plastic housing containing a filter which...
148 GUDID devices
A hand-held, mechanical, breathing-muscle exerciser intended to be used in respiratory therapy to encourage and motivate deep-breathing manoeuvres, typically for the postsurgical treatment and prevention of atelectasis (lung collapse) and to help facilitate...
140 GUDID devices
A sterile device designed to remove bacteria and other suspended particles from flowing water by creating a mechanical barrier to elements larger than 0.2 micrometres. It typically consists of a plastic housing with a connector to the water source [e.g., a ...
136 GUDID devices
"A component of an x-ray system used in diagnostic x-ray imaging applications, e.g., planar x-ray imaging or mammography. It typically consists of a housing containing lead foil strips separated by x-ray transparent spacers. These spacers or ""interspaces""...
133 GUDID devices
A component of an x-ray system used in diagnostic x-ray imaging applications, e.g., planar x-ray imaging or mammography. It typically consists of a housing containing lead foil strips separated by x-ray transparent spacers. These spacers or "interspaces" ar...
123 GUDID devices
A patient-worn, flexible device designed to hold a portable medical device (e.g., long-term recorder, portable oxygen equipment, urine collection bag) during ambulation or sleep; it is neither designed to hold an invasive tube/catheter to the skin surface (...
121 GUDID devices
An ultrasound imaging transducer assembly enclosed in a fluid-resistant, acoustically- and electrically-insulated housing, designed to be inserted and positioned in the oesophagus to obtain ultrasound images of the heart and/or to navigate devices requiring...
108 GUDID devices
A device used in medical imaging applications to shield x-ray film from exposure to room light during transport and insertion into a diagnostic imaging system, film formatter, or film processor. It is typically designed for use with a particular imaging sys...