A sterile non-bioabsorbable tubular device typically implanted at the junction of the abdominal aorta and the common iliac arteries to reduce pressure on an abdominal aortic aneurysm (AAA). It is percutaneously inserted via the femoral artery to the site of...
A non-bioabsorbable tubular device typically implanted at the junction of the abdominal aorta and the common iliac arteries to reduce pressure on an abdominal aortic aneurysm (AAA). It is percutaneously inserted via the femoral artery to the site of implant...
A non-bioabsorbable tubular device typically implanted at the junction of the abdominal aorta and the common iliac arteries to reduce pressure on an abdominal aortic aneurysm (AAA) [includes aortoiliac aneurysm]; it does not contain anticoagulants or pharma...
A non-bioabsorbable tubular device typically implanted at the junction of the abdominal aorta and the common iliac arteries to reduce pressure on an abdominal aortic aneurysm (AAA); it does not contain anticoagulants or pharmaceuticals that prevent narrowin...
A non-bioabsorbable tubular device typically implanted at the junction of the abdominal aorta and the common iliac arteries to reduce pressure on an abdominal aortic aneurysm (AAA). It is percutaneously inserted via the femoral artery to the site of implant...
A sterile artificial substitute for a blood vessel intended to replace or bypass the diseased or injured vessel. It is typically made of woven or knitted polyethylene terephthalate (Dacron) or polytetrafluoroethylene (PTFE) fabrics and is best suited for la...
An implantable artificial substitute for a blood vessel intended to replace or bypass the diseased or injured vessel. It is typically made of woven or knitted polyethylene terephthalate (Dacron) or polytetrafluoroethylene (PTFE) fabrics and is best suited f...
A non-bioabsorbable tubular device intended to be implanted in the common and/or external iliac artery(ies) to maintain arterial patency and luminal diameter in patients with symptomatic atherosclerotic disease. It is made of metal [e.g., stainless steel, n...
A sterile non-bioabsorbable tubular device intended to be implanted in the common and/or external iliac artery(ies) to maintain arterial patency and luminal diameter in patients with symptomatic atherosclerotic disease. It is made of metal [e.g., stainless ...
A sterile non-bioabsorbable tubular device intended to be alternatively implanted in more than one peripheral artery (e.g., iliac, carotid, renal) to indefinitely maintain patency and improve luminal diameter in patients with atherosclerotic disease or foll...
A sterile, sharp bevel-edged, hollow tubular metal instrument designed to obtain a specimen of bone marrow percutaneously. The device is typically available in a variety of large bores, and is sufficiently robust to penetrate bone (usually the hip bone or p...
A sterile, flexible tube (catheter) intended to be percutaneously introduced for the intraluminal mechanical disruption of atheroma plaque from the walls of peripheral arteries. It has a power-driven cutting or abrasive head for slicing/grinding the atherom...
A sterile non-bioabsorbable tubular device intended to be implanted in the iliac and, alternatively, superficial femoral arteries to reline tortuous arteries in patients with symptomatic peripheral vascular disease (PVD). It is percutaneously inserted via t...
A sterile non-bioabsorbable tubular device intended to be implanted in an iliac and/or femoral vein to maintain patency in patients with constrained venous outflow. It is inserted and advanced to the site of implantation with a dedicated catheter where it s...
A non-bioabsorbable tubular device intended to be alternatively implanted in more than one peripheral artery (e.g., iliac, carotid, renal) to indefinitely maintain patency and improve luminal diameter in patients with atherosclerotic disease or following th...
A sterile, sharp bevel-edged, hollow tubular metal instrument designed to percutaneously explant bone marrow (explant is the collection and transfer of living bone marrow from its natural site to a new site, or to a culture medium). The device is typically ...
A non-bioabsorbable tubular device intended to be implanted in a peripheral artery (excludes coronary and intracranial arteries) to maintain patency and improve luminal diameter, and that includes a heparin coating intended to prevent thrombotic vessel re-n...
A non-bioabsorbable tubular device intended to be implanted in an iliac and/or femoral vein to maintain patency in patients with constrained venous outflow. It is inserted and advanced to the site of implantation with a dedicated catheter where it self-expa...
A non-bioabsorbable tubular device intended to be implanted in a peripheral artery (excludes aorta, coronary, pulmonary, and intracranial arteries) to maintain patency and improve luminal diameter, typically in patients with symptomatic peripheral vascular ...
A non-bioabsorbable tubular implantable device intended to maintain patency and improve luminal diameter of a peripheral artery (excludes aorta, coronary, pulmonary, and intracranial arteries), and that includes a heparin coating intended to prevent thrombo...
A sterile, sharp bevel-edged, hollow tubular metal instrument designed to obtain a specimen of bone marrow percutaneously. The device is typically available in a variety of large bores, and is sufficiently robust to penetrate bone (usually the hip bone or p...
An externally-worn orthopaedic device designed to apply traction to the lumbar spine to relieve symptoms of back pain and sciatica. It consists of adjustable components worn superiorly under the rib cage, and inferiorly over the iliac crests, with rods hold...
An externally-worn orthopaedic device designed to apply traction to the lumbar spine to relieve symptoms of back pain and sciatica. It consists of adjustable components worn superiorly under the rib cage, and inferiorly over the iliac crests, with rods hold...