Muscle and Joint pain relief GR Isolate 750 mg
PAIN RELIEF
42 matching records for ISOLA.
PAIN RELIEF
PAIN RELIEF
PAIN RELIEF
Avobenzone,homosalate,Octisalate,Oxybenzone
20251124
20251124
20230711
20230710
2021-11-30
2021-11-30
2021-11-30
2020-10-13
A collection of reagents and other associated materials intended to be used for the extraction and/or isolation of nucleic acid from clinical specimens and/or biological cultures in preparation for subsequent analysis using a nucleic acid-based method. Some...
A mains electricity (AC-powered) laboratory instrument intended to amplify target deoxyribonucleic acid (DNA) or ribonucleic acid (RNA) in a clinical specimen using heat-stable polymerase enzymes and cycles of repeated heating and cooling (i.e., thermal cyc...
A hand-held manual instrument intended to be used to scoop a clinical specimen or microbial isolate for transfer from a primary vessel to a secondary container (e.g., from a specimen collection receptacle to a reagent tube, or from a culture medium to a gen...
An electrically-powered automated or semi-automated laboratory instrument intended to amplify target deoxyribonucleic acid (DNA) or ribonucleic acid (RNA) in a clinical specimen using heat-stable polymerase enzymes and cycles of repeated heating and cooling...
An electrically-powered laboratory instrument intended to amplify target deoxyribonucleic acid (DNA) or ribonucleic acid (RNA) in a clinical specimen using heat-stable polymerase enzymes and cycles of repeated heating and cooling (i.e., thermal cycling) to ...
An electrically-powered automated or semi-automated laboratory instrument intended to amplify target deoxyribonucleic acid (DNA) or ribonucleic acid (RNA) in a clinical specimen using heat-stable polymerase enzymes and cycles of repeated heating and cooling...
A portable, electrically-powered instrument intended to be used by health professionals at the point-of-care to amplify target deoxyribonucleic acid (DNA) or ribonucleic acid (RNA) in a clinical specimen using heat-stable polymerase enzymes and cycles of re...
A mobile device designed to be erected to provide environmental isolation of a contagious patient to protect hospital personnel and other patients from exposure to non-airborne infections (e.g., diphtheria, meningococcus) whilst the patient is being treated...
A collection of reagents and other associated materials (e.g., filters, containers) intended to be used for the isolation and concentration of intestinal parasites [e.g., helminth eggs and larvae, protozoan trophozoites and cysts] from a faecal specimen, us...
A device designed to be used in a mains electricity alternating current (AC) circuit to increase (step-up) or decrease (step-down) voltage, to provide the specified voltage to a parent device; it is not a built-in component of the parent device. It provides...
A substance or reactant intended to be used for the isolation of red blood cells (RBCs) from a whole blood clinical specimen by promoting aggregation of RBCs. It is primarily used in a blood bank or transfusion centre for blood component separation (e.g., i...
A portable, electrically-powered instrument intended to be used by healthcare professionals at the point-of-care to amplify target deoxyribonucleic acid (DNA) or ribonucleic acid (RNA) in a clinical specimen using heat-stable polymerase enzymes and cycles o...
A disc impregnated with a defined amount of the antimicrobials vancomycin and colistin, intended to be used for the selective isolation of microorganisms that are not susceptible to the antimicrobials (e.g., Neisseria meningitidis) from a clinical specimen ...
A prefabricated device intended to provide a permanent intermediate fixture level between a dental implant and the final prosthesis/restoration (e.g., bridge, single tooth, overdenture). It includes one or more structural component(s) [e.g., abutment, ball,...
A noninvasive sheet designed to cover a portion of a patient’s anatomy during a surgical procedure to function as a barrier to cross contamination (e.g., isolate a site of surgical incision, protect non-operative anatomy). It is not designed with specific h...
A garment made of natural and/or synthetic materials intended to be worn by healthcare providers or visitors to isolate themselves from patients. The isolation gown helps to protect the patient (e.g., burn patients) from the transfer of infectious agents ca...
A component of a rigid or flexible endoscope assembly designed as a tube through which an endoscope (e.g., hysteroscope) and endoscopic elements are introduced and assembled to create a complete operative endoscopic unit; it is also designed to function as ...
A non-sterile, noninvasive flat sheet designed to cover a portion of a patient’s anatomy during a surgical procedure to isolate a specific anatomical site (e.g., site of surgical incision) from potential contamination (e.g., microbial, substance). The devic...
A collection of reagents and other associated materials intended to be used to verify the performance of one or multiple biochemical tests used for the differentiation and/or identification of multiple bacteria species that have been isolated by culture fro...
A sterile, noninvasive flat sheet designed to cover a portion of a patient’s anatomy during a surgical procedure to isolate a specific anatomical site (e.g., site of surgical incision) from potential contamination (e.g., microbial, substance). The device ma...
A noninvasive sheet designed to cover a portion of a patient’s anatomy during a surgical procedure to function as a barrier to cross contamination (e.g., isolate a site of surgical incision, protect non-operative anatomy). It is not designed with specific h...
A non-patient-contact, insulated, electrical cord with a connector (plug) at both ends designed to transmit electrical power and/or signal (data) between medical devices (e.g., to connect a lead, electrical catheter, handpiece, or monitor to a parent device...
A metallic device intended to be permanently implanted around the neck of an aneurysm (a balloon-like sac formed on a blood vessel) for occlusion, to prevent it from bleeding or bursting and to isolate it from the rest of the vessel. The device is typically...
A sterile, metallic device intended to be permanently implanted around the neck of an aneurysm (a balloon-like sac formed on a blood vessel) for occlusion, to prevent it from bleeding or bursting and to isolate it from the rest of the vessel. The device is ...
A custom-made device intended to provide a permanent intermediate fixture level between a dental implant and the final prosthesis/restoration (e.g., bridge, single tooth, overdenture). It includes one or more structural component(s) [e.g., abutment, ball, b...
An underwear designed to retain urine leakage in incontinent adults and older children. It typically consists of a single-use man?s brief or woman?s panty with external softness and shape resembling regular underwear, and an internal pad and/or isolated she...
A mains electricity (AC-powered) mobile (on wheels) assembly of devices that uses multiple therapeutic modalities [e.g., intense pulsed light (IPL), laser, and radio-frequency (RF) energy] in combination and/or in isolation for ablative and non-ablative tre...
A non-sterile substance intended to be used as a medium for the efficient transmission of electrical signals between an electrode and the body, and for the reduction of the isolation properties of the skin. It is typically in the form of a gel, paste, spray...
One or multiple immunoglobulins capable of binding to specific antigenic determinants and intended to be used for the qualitative and/or quantitative detection of antigens from Escherichia coli (E. coli) bacteria in a clinical specimen and/or culture isolate.
A sheet of elastomeric material made of Hevea natural rubber latex (NRL) that is punched with holes and placed over the teeth during dental procedures. It can have a variety of functions such as: 1) to isolate the field of operation from the rest of the ora...