AVENASTER FUNGAL NAIL CARE DUO SET (NIGHT)
UNDECYLENIC ACID 25% FUNGAL NAIL CARE DUO SET (NIGHT)
50 matching records for Infusion Set.
UNDECYLENIC ACID 25% FUNGAL NAIL CARE DUO SET (NIGHT)
UREA 20% FUNGAL NAIL CARE DUO SET (DAY)
BEAUTYTURESS COLLAGEN MOISTURIZING FIRMING 14-PIECE SET
HYALURONATE SODIUM
OXYGEN
OXYGEN
OXYGEN
NITROGLYCERIN
AVOBENZONE, HOMOSALATE, OCTISALATE, OCTOCRYLENE
ETHYL ALCOHOL
ETHYL ALCOHOL
ETHYL ALCOHOL
ETHYL ALCOHOL
ETHYL ALCOHOL
ETHYL ALCOHOL
ADEPS SUILLUS, BRYONIA (ALBA), CALCAREA PHOSPHORICA, CHOLINUM, DNA, DOPAMINE (HYDROCHLORIDE), FERRUM PHOSPHORICUM, FOLIC ACID, INSULINUM (HUMAN), LEPTIN, MAGNESIA MURIATICA, L-METHIONINE, METHYLCOBALAMIN, PROTEUS (VULGARIS), RHUS TOX, RIBOFLAVINUM, RUTA GRA...
ALCOHOL
AVABENZONE 3% HOMOSALATE 10% OCTISALATE 5%
HOMOSALATE, OCTOCRYLENE,OCTISALATE,AVOBENZONE
ALCOHOL
A collection of sterile devices designed to perform an intraosseous (IO) infusion (i.e., an infusion directly into the bone's medullary cavity for the purpose of administering emergency medications and other fluids). It typically consists of a needle (possi...
A mains electricity (AC-powered) device designed to facilitate the accurate and consistent administration of drugs and solutions which can be delivered via intravenous, subcutaneous, arterial, epidural, and intracavital routes using a dedicated infusion set...
An electrically-powered, non-ambulatory (bedside) device designed to facilitate the accurate and consistent administration of a single drug/solution which can be delivered via intravenous, subcutaneous, arterial, epidural, and intracavital routes using a de...
An electrically-powered, non-ambulatory (bedside) device designed to facilitate the accurate and consistent administration of drugs and solutions which can be delivered via intravenous, subcutaneous, arterial, epidural, and intracavital routes using a dedic...
A sterile device designed to be used in conjunction with an infusion pump or a device containing an infusion pump (e.g., a physiology-monitoring sedation system, physiology-monitoring anaesthesia system), for the delivery of an intravenous (IV) medication (...
An electrically-powered, non-ambulatory (bedside) device designed to facilitate the simultaneous, accurate, and consistent administration of multiple drugs/solutions (multichannel) from a standard infusion bag or bottle, via intravenous, subcutaneous, arter...
An electronic device intended to monitor and display the volume and flow rate of intravenous (IV) fluids administration during gravity infusion, providing an alarm (visible/audible) when pre-set limits are exceeded. It is attached directly to the drip chamb...
A battery-powered ambulatory device intended to provide continuous or intermittent administration of medication, commonly for antibiotic therapy, chemotherapy, or patient-controlled analgesia (PCA); it is not dedicated to insulin infusion. It consists of a ...
A battery-powered ambulatory device intended to provide continuous or intermittent administration of medication, commonly for antibiotic therapy, chemotherapy, or patient-controlled analgesia (PCA); it is not dedicated to insulin infusion. It consists of a ...
A battery-powered ambulatory device intended to provide continuous or intermittent administration of medication, commonly for antibiotic therapy, chemotherapy, or patient-controlled analgesia (PCA); it is not dedicated to insulin infusion. It consists of a ...
A sterile device(s) used in conjunction with a conduction blood/fluid warmer to heat banked blood, blood products, and intravenous (IV) fluids to a temperature appropriate for infusion into a patient. It typically consists of a pouch(es) or a flexible casse...
A collection of devices used in conjunction with a conduction blood/fluid warmer to heat banked blood, blood products, and intravenous (IV) fluids to a temperature appropriate for infusion into a patient. It consists of a pouch(es) or a flexible cassette th...
A collection of devices used in conjunction with a convection blood/fluid warmer to heat banked blood, blood products, and intravenous (IV) fluids to a temperature appropriate for infusion into a patient. It may consist of coiled tubing, or other design, th...
A sterile device(s) used in conjunction with a convection blood/fluid warmer to heat banked blood, blood products, and intravenous (IV) fluids to a temperature appropriate for infusion into a patient. It may consist of coiled tubing, or other design, throug...
A collection of devices used in conjunction with a radiation blood/fluid warmer to heat banked blood, blood products, and intravenous (IV) fluids to a temperature appropriate for infusion into a patient. It typically consists of a pouch(es) or a flexible ca...
An intravascular administration set intended to be used to administer blood from a container to a patient's vascular system through a needle or catheter inserted into a vein. The device typically includes a needle or catheter, tubing, a flow regulator, a dr...
A sterile, intravascular administration set used to administer blood from a container to a patient's vascular system through a needle or catheter inserted into a vein. The device typically includes a needle or catheter, tubing, a flow regulator, a drip cham...
A sterile, intravascular administration set used to remove a diseased infant's blood and replace it with fresh donor blood or plasma. The device typically includes a needle or catheter, tubing, a flow regulator, a drip chamber, an infusion line filter, a st...
A sterile device designed to allow access to either the Y-site of an intravenous (IV) line or an injection adaptor on the infusion catheter. Typically, a needle located inside a plastic housing can be inserted into a standard septum and a Luer fitting locat...
A collection of sterile devices intended to be used with a mechanical infusion pump (non-electric) to enable the intermittent or continuous infusion of medication, typically for antibiotic therapy, chemotherapy, or pain management [including patient-control...
A collection of devices intended to be used with a mechanical infusion pump (non-electric) to enable the intermittent or continuous infusion of medication (not included), typically for antibiotic therapy, chemotherapy, or pain management [including patient-...
A mains electricity (AC-powered) device, which may include rechargeable batteries, designed for in-line heating of banked blood, blood products, intravenous (IV) solutions, and irrigation fluids, typically from about 4ºC to near body temperature (i.e., 35 t...
An electrically-powered device designed for in-line heating of banked blood, blood products, intravenous (IV) solutions, and irrigation fluids, typically from about 4ºC to near body temperature (i.e., 35 to 37ºC) before infusion, through the conduction of h...
A battery-powered ambulatory device intended to provide continuous or intermittent administration of non-specific drugs and/or solutions. It consists of a small unit with a pumping mechanism and an infusion-rate controller, and is used with a dedicated sing...
An electrically-powered device designed for in-line heating of banked blood, blood products, intravenous (IV) solutions, and irrigation fluids, typically from about 4ºC to near body temperature (i.e., 35 to 37ºC) before infusion, through the convection of h...
A mains electricity (AC-powered) device used to control and monitor the gravity infusion of intravenous (IV) fluids, providing an alarm (visible/audible) when pre-set limits are exceeded. It is available in two main configurations: 1) a device with an elect...
A mains electricity (AC-powered) device designed for in-line heating of banked blood, blood products, intravenous (IV) solutions, and irrigation fluids, typically from about 4?C to near body temperature (i.e., 35 to 37?C) before infusion, through the convec...
An electrically-powered device intended to be used to control and monitor the gravity infusion of intravenous (IV) fluids, providing an alarm (visible/audible) when pre-set limits are exceeded. It is available in two main configurations: 1) a device with an...
A mains electricity (AC-powered) device, which may include internal rechargeable batteries, intended to facilitate the accurate and consistent administration of non-specific fluid medications from a standard infusion bag, syringe, or bottle, into a patient ...
A device assembly designed to assess the performance of infusion pumps by accurately measuring, evaluating, displaying, and/or recording a set of pump variables (typically output flow, volume delivery, and occlusion pressure needed to activate the pump alar...