A sterile, noninvasive, hand-held, battery-powered unit intended to deliver a low-level electric current to break the connection between a vascular (neurovascular or peripheral) implantable device, and its deployment device (i.e., implant inserter or delive...
A noninvasive, hand-held, electrically-powered unit intended to deliver a low-level electric current to break the connection between a vascular implantable device (typically a neurovascular or peripheral embolization coil or stent) and its deployment device...
A hand-held device intended to direct the insertion and placement of a tympanostomy tube (otherwise known as a myringotomy tube, grommet or an aural vent tube) through the external ear canal during ear/nose/throat (ENT) surgery. A tympanostomy tube is a dev...
A device intended to direct the insertion and placement of a tympanostomy tube (otherwise known as myringotomy tube) through the external ear canal during ear/nose/throat (ENT) surgery. A tympanostomy tube is a device used to provide drainage from the middl...
A noninvasive, hand-held, battery-powered unit intended to deliver a low-level electric current to break the connection between a vascular (neurovascular or peripheral) implantable device, and its deployment device (i.e., implant inserter or delivery wire) ...
A sterile, long, thin surgical device used to advance an embolization implant, e.g. an embolic coil, through the length of an appropriate catheter so that the implant is ready for discharge (implantation) when the catheter has been surgically positioned at ...
A hand-held device intended to direct the insertion and placement of a tympanostomy tube (otherwise known as a myringotomy tube, grommet or an aural vent tube) through the external ear canal during ear/nose/throat (ENT) surgery. A tympanostomy tube is a dev...
A hand-held device intended to direct the insertion and placement of a tympanostomy tube (otherwise known as myringotomy tube or grommet) through the external ear canal during ear/nose/throat (ENT) surgery. A tympanostomy tube is a device used to provide dr...
A long, thin, manual surgical device intended to advance an embolization implant (e.g. an embolic coil) through the length of an appropriate catheter so that the implant is ready for discharge (implantation) when the catheter has been surgically positioned ...
A noninvasive, hand-held, electrically-powered unit intended to deliver a low-level electric current to break the connection between a vascular implantable device (typically a neurovascular or peripheral embolization coil or stent) and its deployment device...
A hand-held manual surgical instrument designed to insert or extract an implantable orthopaedic device (e.g., a bone nail, spiral blade, or bone fixation plate) through application of a striking or screwing force. It is an instrument in a one-piece or modul...
A hand-held manual surgical instrument designed for the surgical insertion and/or extraction of a non-tissue based (inorganic) orthopaedic implant (e.g., a bone nail, spiral blade, or bone fixation plate). It is an instrument in a one-piece or modular confi...
A device designed to deliver bone graft filling material (autologous, allogeneic, xenogeneic, or synthetic) during an orthopaedic procedure to enable the filling of bone gaps intended to be fused. It is a funnel-shaped device; the funnel being bowl-shaped w...
A collection of sterile devices and supplies used in combination for the implantation of an embolization implant that will purposely create permanent or temporary obstruction, i.e., stop the flow of blood, in arteries/blood vessels. The kit will typically c...
A hand-held manual surgical instrument designed to insert or extract an implantable orthopaedic device (e.g., a bone nail, spiral blade, or bone fixation plate) through application of a striking or screwing force. It is an instrument in a one-piece or modul...
A hand-held manual surgical instrument designed to push a cartilage or bone graft into a position from which the graft can be delivered into a chondral defect [e.g., during anterior cruciate ligament (ACL) reconstruction surgery]. This device is available i...
A hand-held manual surgical instrument designed for the surgical insertion and/or extraction of a non-tissue based (inorganic) orthopaedic implant (e.g., a bone nail, spiral blade, or bone fixation plate). It is an instrument in a one-piece or modular confi...
A non-sterile, hand-held manual orthopaedic surgical instrument designed to be used to measure the diameter of the medullary canal of a bone (e.g., femur, humerus) in order to select the appropriate size orthopaedic cement restrictor implant. It may be in t...
A hand-held manual surgical instrument designed to push a cartilage or bone graft into a position from which the graft can be delivered into a chondral defect [e.g., during anterior cruciate ligament (ACL) reconstruction surgery]. This device is available i...
A collection of devices used to facilitate the implantation of a ureteral stent, via the natural orifice or percutaneously through a tortuous ureter, in order to maintain ureteral patency. The devices are typically made of high-grade stainless steel and/or ...
A hand-held manual surgical instrument designed to drive (insert) a tack into bone, typically to fixate an orthopaedic plate or sheet. It is typically formed with a shaft made of high-grade stainless steel and a handle at the proximal end made of metal or s...
A small, sterile, bioabsorbable, cylindrical shaft, typically with a flat, rounded head at one end and tapered to a point at the other, intended to be implanted into craniofacial bone (includes maxilla and/or mandible) to provide stabilization for fracture ...
A sterile, open-ended, non-optical circular band intended to be used to enhance the mechanical stability of a subluxated crystalline lens capsule in the presence of weak or absent supporting zonules. The device, commonly known as a capsular tension ring (CT...
A noninvasive hand-held manual device designed to facilitate insertion, reinsertion, and/or removal of a dental power tool endpiece (e.g., oscillatory file/rasp, saw, or scalpel) into/from a power tool handpiece; it may in addition be used as a holder withi...
A nonimplantable thin rod intended to be temporarily introduced, with a dedicated inserter (not included), into vertebral bone to assist with the positioning of an implantable device and/or surgical instrument (e.g., fixation plate, distractor/retractor) du...
A nonimplantable thin rod intended to be temporarily introduced, with a dedicated inserter (not included), into vertebral bone to assist with the positioning of an implantable device and/or surgical instrument (e.g., fixation plate, distractor/retractor) du...
A device designed to insert and remove hard and semi-rigid contact lenses from the eye. It typically consists of a small, hand-held device that has a handle and a concave cup-like distal end; some devices include a vented handle that provides manually-adjus...
A hand-held manual surgical instrument designed to push a cartilage or bone graft into a position from which the graft can be delivered into a chondral defect [e.g., during anterior cruciate ligament (ACL) reconstruction surgery]. This device is available i...
A small, bioabsorbable, cylindrical shaft, typically with a flat, rounded head at one end and tapered to a point at the other, intended to be implanted into craniofacial bone (includes maxilla and/or mandible) to provide stabilization for fracture repair an...
A non-sterile hand-operated surgical instrument intended for the implantation of a capsular tension ring (CTR) into the crystalline lens capsular bag during intraocular lens (IOL) surgery (e.g., cataract extraction). It typically consists of a tubular dista...