2 GUDID devices
A mains electricity (AC-powered) unit that is connected to a power tool or a power tool system and used to regulate the torque effect of that power tool. This is to give the tool greater or lesser torque effect assisting in the power requirement of the inte...
30 GUDID devices
A dedicated battery-powered assembly of devices intended to be used to remove circular sections of the skull vault (calvarium) to provide access to the interior for diagnosis (e.g., the insertion of a neuroscope), or treatments [e.g., to alleviate intracran...
27 GUDID devices
A noninvasive hand-held manual device designed to facilitate insertion, reinsertion, and/or removal of a dental power tool endpiece (e.g., oscillatory file/rasp, saw, or scalpel) into/from a power tool handpiece; it may in addition be used as a holder withi...
178 GUDID devices
A device intended to connect to a surgical power tool system motor [it is locked and held in a collet or quick coupling and not simply gripped in a drill chuck (Jacobs chuck)] to convert the non-dedicated mechanical energy provided by the motor to a dedicat...
109 GUDID devices
A device intended to connect to a surgical power tool system motor [it is locked and held in a collet or quick coupling and not simply gripped in a drill chuck (Jacobs chuck)] to convert the non-dedicated mechanical energy provided by the motor to a dedicat...
33 GUDID devices
A device intended to connect to a surgical power tool system motor [it is locked and held in a collet or quick coupling and not simply gripped in a drill chuck (Jacobs chuck)] to convert the non-dedicated mechanical energy provided by the motor to a dedicat...
1 GUDID devices
An invasive device designed for the implantation of a gastro-oesophageal antireflux fundal implant (e.g., space-occupying extraluminal implant, intraluminal clip/fastener) used to help prevent hiatal hernia and gastro-oesophageal reflux. It is introduced in...
6,838 GUDID devices
A shaft of metal with an obtuse, V-shaped cutting edge designed to be rotated to bore into bone to create a hole of the same dimension as the diameter of the shaft. This device, commonly called a "twist drill", has a cylindrical design with a double-edged c...
1,817 GUDID devices
"A shaft of metal with an obtuse, V-shaped cutting edge designed to be rotated to bore into bone to create a hole of the same dimension as the diameter of the shaft. This device, commonly called a ""twist drill"", has a cylindrical design with a double-edge...
1,652 GUDID devices
A shaft of metal with an obtuse, V-shaped cutting edge designed to be rotated to bore into bone to create a hole of the same dimension as the diameter of the shaft. This device, commonly called a "twist drill", has a cylindrical design with a double-edged c...
1,602 GUDID devices
A shaft of metal intended to be mounted into an appropriate surgical power tool (e.g., a pneumatic reamer or drilling system handpiece with appropriate torque capacity) and rotated to bore into hard/tough tissues (e.g., bone, cartilage) to clear a channel o...
1,396 GUDID devices
A sterile shaft of metal with an obtuse, V-shaped cutting edge designed to be rotated to bore into bone to create a hole of the same dimension as the diameter of the shaft. This device, commonly called a "twist drill", has a cylindrical design with a double...
1,249 GUDID devices
A non-sterile shaft of metal with an obtuse, V-shaped cutting edge designed to be rotated to bore into bone to create a hole of the same dimension as the diameter of the shaft. This device, commonly called a "twist drill", has a cylindrical design with a do...
827 GUDID devices
A metal shaft intended to be mounted into an appropriate surgical power tool (e.g., a pneumatic reamer or drilling system handpiece with appropriate torque capacity) and rotated to bore into hard/tough tissues (e.g., bone, cartilage) in order to clear a cha...
557 GUDID devices
A sterile metal shaft intended to be mounted into an appropriate surgical power tool (e.g., a pneumatic reamer or drilling system handpiece with appropriate torque capacity) and rotated to bore into hard/tough tissues (e.g., bone, cartilage) in order to cle...
358 GUDID devices
"A shaft of metal with an obtuse, V-shaped cutting edge designed to be rotated to bore into bone to create a hole of the same dimension as the diameter of the shaft. This device, commonly called a ""twist drill"", has a cylindrical design with a double-edge...
299 GUDID devices
A rod-like orthopaedic surgical instrument designed to be inserted (screwed) through the insertion handle of an orthopaedic implant aiming arm to impart a force upon a proximally inserted bone nail locking screw thus creating compression on the proximal sec...
204 GUDID devices
A non-sterile metal shaft intended to be mounted into an appropriate surgical power tool (e.g., a pneumatic reamer or drilling system handpiece with appropriate torque capacity) and rotated to bore into hard/tough tissues (e.g., bone, cartilage) in order to...
70 GUDID devices
"A non-sterile shaft of metal with an obtuse, V-shaped cutting edge designed to be rotated to bore into bone to create a hole of the same dimension as the diameter of the shaft. This device, commonly called a ""twist drill"", has a cylindrical design with a...
61 GUDID devices
A small device in the form of a ring or cylinder intended to be placed on a surgically-invasive dental instrument or power tool endpiece (e.g., file/rasp, drill bit, reamer) to limit the depth of insertion typically into the tooth or bone; it is typically m...
37 GUDID devices
A sterile, implantable artificial substitute for the proximal interphalangeal (PIP) joint(s) of the hand (finger) which typically has been damaged by rheumatoid, degenerative, or traumatic arthritis. The device typically consists of proximal and distal meta...
11 GUDID devices
A flexible cylindrical device intended to accept an orthopaedic reamer head on its distal end and used during a procedure to open and enlarge a medullary canal (e.g., in the femur), for the insertion of devices during prosthesis implantation or for fracture...
11 GUDID devices
A thin shaft of metal with a sharp distal end intended to drill a small diameter hole into a small bone for insertion of an orthopaedic bone staple, typically for fixation following osteotomy. It may include markings to help gauge the size of the staple to ...
6 GUDID devices
A hand-held manual surgical instrument intended to be used to realign or reposition a heart valve prosthesis after initial insertion and positioning with a heart valve prosthesis holder. The device may be a one-piece instrument or attached to a separate han...
6 GUDID devices
An assembly of devices used together with certain types of ocular rim prostheses for patients who wish to gain improved prosthetic eye motility by coupling the ocular implant to the prosthetic eye. This device will typically consist of screws made of, e.g.,...
3 GUDID devices
A hand-held, electrically-powered device intended to assist placement of a block (tamp) which limits the passage of earmould impression material when taking an ear canal impression. It consists of a disposable transparent probe illuminated with a reusable l...
3 GUDID devices
A sterile, invasive, magnetic device intended to be percutaneously inserted into the body to be used as a manoeuvrable object to permit transcutaneous grasping/manipulation/retraction of soft tissues/organs (e.g., gallbladder) during endoscopic/laparoscopic...
1 GUDID devices
A sterile device intended to be used as a dedicated tool for the insertion and/or removal of a hypopharyngeal fistula occluder. It is in the form of a thin tube with a mechanism for attaching the occluder at the distal end so that it can be pulled into, or ...
1 GUDID devices
A collection of manual surgical instruments intended to be used during implantation of a penile prosthesis [for the treatment of erectile dysfunction (ED)]. The kit typically contains tools associated with insertion, measurement, and/or assembly of the impl...