A hand-held, pistol-like surgical instrument that is used to deploy and secure an infusion port/tack assembly onto the patient's abdominal muscle (rectus fascia). The instrument, loaded with the port/tack assembly, is inserted through an incision made in th...
A rigid, hand-held manual surgical instrument designed to be introduced through the working channel of an endoscope and/or an endoscopic port (e.g., laparoscopic port) primarily for grasping and manipulating tissues during endoscopic surgery. It has proxima...
A single-lumen surgical device intended to be percutaneously inserted into a joint to create an access port for an arthroscope/arthroscopic instrument during arthroscopy. The cannula is designed to facilitate the passage of surgical instruments while preven...
A sterile sleeve assembly made of plastic materials intended to retract a small abdominal incision to allow multiple laparoscopic instruments to pass into the abdomen at the same time during a laparoscopic procedure. It will typically have an introducer tha...
A single-lumen, surgical device intended to be percutaneously inserted into a joint to create an access port for an arthroscope/arthroscopic instrument during arthroscopy. The cannula is designed to facilitate the passage of surgical instruments while preve...
A rigid, hand-held manual surgical instrument designed to be introduced through the working channel of an endoscope and/or an endoscopic port (e.g., laparoscopic port) primarily for grasping and manipulating tissues during endoscopic surgery. It has proxima...
A rigid, hand-held manual surgical instrument designed to be introduced through the working channel of an endoscope and/or an endoscopic port (e.g., laparoscopic port) primarily for grasping and manipulating tissues during endoscopic surgery. It has proxima...
A non-sterile device intended to protect a sterile, battery-powered surgical instrument during insertion of a non-sterile battery such that the sterility of the surgical instrument is maintained; it may be intended for use preoperatively and/or during surge...
A multi-lumen sleeve assembly intended to retract a small abdominal incision to allow multiple laparoscopic instruments to access the abdominal cavity simultaneously through a single abdominal incision, during minimally-invasive laparoscopic surgery. It wil...
A sterile, nonimplantable, intraoperative surgical instrument designed to be inserted into the abdominal or thoracic cavity through a compatible endoscopic instrument (e.g., an access port) to provide hands-free retraction of a selected organ by anchoring i...
A hand-held manual surgical instrument designed for the mechanical crushing of renal stones (calculi) in the urinary tract and/or bladder. It is typically designed with a sturdy pair of jaws at the distal end that are placed over and crush the stone when th...
A sterile, rigid, laparoscopic device, covered with a sheath of electrical insulation, designed to perform through a compatible laparoscopic instrument (e.g., an access port) and to be connected to an electrosurgical diathermy generator when required to pro...
A non-sterile, hand-held, manually-operated surgical instrument designed to perform through a compatible endoscopic instrument (e.g., an access port) to insert, manipulate, and activate (apply) an internally-anchored endoscopic retractor to provide hands-fr...
A single-lumen surgical device intended to be percutaneously inserted through the abdominal wall to create an access port for a laparoscope/laparoscopic instrument during laparoscopy. The cannula is provided with a shut-off valve for gas/fluid supply, and o...
A single-lumen surgical device intended to be percutaneously inserted through the abdominal wall to create an access port for a laparoscope/laparoscopic instrument during laparoscopy. The cannula is often provided with a shut-off valve for gas/fluid supply,...
A sterile, single-lumen surgical device intended to be percutaneously inserted through the abdominal wall to create an access port for a laparoscope/laparoscopic instrument during laparoscopy. The cannula is often provided with a shut-off valve for gas/flui...
A rigid, hand-held manual surgical instrument designed to be introduced through a laparoscope/laparoscopic port for: 1) atraumatic grasping/clamping of soft tissues (e.g., gallbladder); and 2) access adjacent to the site of clamping (e.g., during laparoscop...
A rigid, surgical instrument with a sharp pyramidal or conical point intended to puncture the abdominal wall to facilitate the introduction of a separate laparoscopic access cannula (not included) during laparoscopy. It is intended to fill the lumen of the ...
An impervious, flexible, sterile container intended to be used during minimally-invasive, typically keyhole, surgical techniques (e.g., laparoscopic) to extract dissected patient body tissue. The device is inserted into the body through a large bore cannula...
A sterile, sharp bevel-edged, hollow tubular metal instrument intended to be attached to a syringe and designed for the therapeutic injection or infusion of medicinal substances directly beneath the skin layer. This is a single-use device.
A sterile surgical instrument intended to be placed intraoperatively in a surgically-prepared mammary pocket to provide a volume measurement for the appropriate selection of a breast implant (mammary prosthesis). The device consists of a balloon-like elasto...
A battery-powered, hand-held, electronic instrument designed to measure the maximum rate of expiratory gas flow [peak expiratory flow (PEF) or peak expiratory flow rate (PEFR)] and forced expiratory volume (FEV) from the lungs. It typically includes a mouth...
A sterile, rigid, surgical instrument with a sharp pyramidal or conical point intended to puncture the abdominal wall to facilitate the introduction of a laparoscopic access cannula (not included) during laparoscopy. It is intended to fill the lumen of the ...
A sterile, sharp bevel-edged, hollow tubular metal instrument attached to a syringe and designed for the therapeutic injection or infusion of medicinal substances directly beneath the skin layer. This is a single-use device.
A battery-powered, hand-held instrument designed to measure the maximum rate of expiratory gas flow [peak expiratory flow (PEF) or peak expiratory flow rate (PEFR)] and forced expiratory volume (FEV) from the lungs. It typically includes a mouthpiece for pa...
A frame-like assembly of surgical instruments/devices intended to be used to create a self-locking, self-retaining mechanism dedicated to the temporary parting of dorsal tissue to enable access for spinal surgery. It includes a mounting frame, with retracti...
A nonimplantable, rigid tube intended to be surgically inserted through the skull to access the brain (e.g., cerebral ventricles) for cerebrospinal fluid (CSF) drainage, infusion of materials, and/or for use as a port through which instruments, leads and/or...
A magnification instrument designed with a standard microscope configuration [the object viewed through an ocular(s) from above] used to magnify and study specimens and small objects by transmitted visible light. It is widely used in laboratories and for re...
A sterile, nonimplantable, rigid tube intended to be surgically inserted through the skull to access the brain (e.g., cerebral ventricles) for cerebrospinal fluid (CSF) drainage, infusion of materials, and/or for use as a port through which instruments, lea...
A sterile, rigid surgical instrument designed to be introduced through an endoscope (e.g., laparoscope, hysteroscope) or laparoscopic port, to mechanically cut tissues during an endoscopic/laparoscopic surgical procedure. It is a hand-held device typically ...