An optical device, generally referred to as an intraocular lens (IOL), intended to be implanted permanently in the posterior chamber of the eye (ring-like space filled with aqueous humor between the iris, the crystalline lens, and the ciliary body) to provi...
An optical device, generally referred to as an intraocular lens (IOL), intended to be implanted permanently in the posterior chamber of the eye (ring-like space filled with aqueous humor between the iris, the crystalline lens, and the ciliary body) to repla...
An optical device, generally referred to as an intraocular lens (IOL), intended to be implanted permanently in the posterior chamber of the eye (ring-like space filled with aqueous humor between the iris, the crystalline lens, and the ciliary body) to provi...
An optical device, generally referred to as an intraocular lens (IOL), intended to be implanted permanently in the posterior chamber of the eye (ring-like space filled with aqueous humor between the iris, the crystalline lens, and the ciliary body) to repla...
An optical device, generally referred to as an intraocular lens (IOL), intended to be implanted permanently in the region of the eye posterior of the cornea and anterior of the iris (anterior chamber) to replace the natural lens (crystalline lens), typicall...
An optical device, generally referred to as an intraocular lens (IOL), intended to be implanted permanently in the region of the eye posterior of the cornea and anterior of the iris (anterior chamber) to provide refractive correction of vision without remov...
A sterile optical device intended to be implanted into the posterior chamber of the eye to replace the natural lens (crystalline lens), typically because it has been clouded by a cataract. It consists of an intraocular lens (IOL) containing a small aperture...
An optical device, generally referred to as an intraocular lens (IOL), intended to be implanted permanently in the region of the eye posterior of the cornea and anterior of the iris (anterior chamber) to replace the natural lens (crystalline lens), typicall...
A hand-held, blunt, manual ophthalmic surgical instrument intended for manipulation/retraction of intraocular structures, lens nucleus splitting/manipulation, removal of foreign bodies in the eye, corneal manipulation (e.g., LASIK flap lifting), and/or in s...
A sterile device designed to contain an intraocular lens (IOL), that may have been pre-folded, to facilitate the insertion (launching) of the folded IOL into the anterior or posterior chamber of the eye through a small incision during ophthalmic surgery. Co...
A hand-held, blunt, manual ophthalmic surgical instrument intended for manipulation/retraction of intraocular structures, lens nucleus splitting/manipulation, removal of foreign bodies in the eye, corneal manipulation (e.g., LASIK flap lifting), and/or in s...
A hand-held manual ophthalmic surgical instrument designed to expel (launch) a prepared (folded) intraocular lens (IOL) from an attached IOL insertion cartridge into the anterior or posterior chamber of the eye during ophthalmic implantation surgery. It has...
A hand-held, manual, ophthalmic surgical instrument designed to expel (launch) a prepared folded intraocular lens (IOL) from an attached IOL insertion cartridge into the anterior or posterior chamber of the eye during ophthalmic surgery. Commonly known as t...
A hand-held manual ophthalmic surgical instrument designed to expel (launch) a prepared (folded) intraocular lens (IOL) from an attached IOL insertion cartridge into the anterior or posterior chamber of the eye during ophthalmic implantation surgery. It has...
A sterile, hand-held, manual ophthalmic surgical instrument designed to expel (launch) a prepared folded intraocular lens (IOL) from an attached IOL insertion cartridge into the anterior or posterior chamber of the eye during ophthalmic surgery. Commonly kn...
A hand-held, sterile, device designed to uniformly fold a foldable intraocular lens (IOL) in order to reduce its natural physical size so that the IOL can be removed from the IOL folder with an implantation forceps and be implanted into the anterior or post...
A hand-held, manual, ophthalmic surgical instrument intended to be used to cut an intraocular lens (IOL) during IOL removal. It comprises two pivoted blades which cut with a shearing action directly adjacent to the handles (i.e., not a probe-like device). I...
A hand-held, manual, ophthalmic surgical instrument intended to be used to cut an intraocular lens (IOL) during IOL removal. It comprises two pivoted blades which cut with a shearing action directly adjacent to the handles (i.e., not a probe-like device). I...
A hand-held, manual, ophthalmic surgical instrument intended to be used to cut an in situ intraocular lens (IOL) as part of IOL removal. It comprises a shearing blade(s) at the end of a probe-like shaft with a proximal slimline handle, typically operated by...
An application software designed to provide algorithms to assist a surgeon in performing calculations to help predict the amount of postoperative corneal astigmatism that needs to be corrected in order to optimize intraocular lens (IOL) model selection and ...
A sterile device intended to be attached to, and enable temporary extension of, the haptic loops of an intraocular lens (IOL) to facilitate implantation of the IOL in the posterior chamber of the eye. It typically includes two lengths of cord with connector...
A hand-held, manual, ophthalmic surgical instrument intended to be used to cut the haptics of an intraocular lens (IOL) during IOL removal. It comprises a shearing blade(s) at the end of a probe-like shaft with a proximal slimline handle, typically operated...
A hand-held, direct current (DC) powered ophthalmic surgical instrument designed to expel (launch) a prepared folded intraocular lens (IOL) from an attached IOL insertion cartridge into the anterior chamber of the eye in association with cataract removal. I...
A sterile, open-ended, non-optical circular band intended to be used to enhance the mechanical stability of a subluxated crystalline lens capsule in the presence of weak or absent supporting zonules. The device, commonly known as a capsular tension ring (CT...
An implantable optical device designed to improve visual acuity in patients with bilateral moderate to profound central vision impairment due to age related macular degeneration. It is a non-active micro-Galilean telescope consisting of a doublet lens confi...
A hand-held, manual, ophthalmic surgical instrument intended to be used to rotate/manipulate the natural lens nucleus, typically during ultrasonic emulsification prior to aspiration in preparation for intraocular lens implantation. It has a probe-like form,...
A bench-top, mains electricity (AC-powered) ophthalmic instrument designed to measure the curvature of the anterior surface of the cornea, particularly for determining the presence, extent, and axis of astigmatism (an error of refraction in the eye due to t...
A non-sterile hand-operated surgical instrument intended for the implantation of a capsular tension ring (CTR) into the crystalline lens capsular bag during intraocular lens (IOL) surgery (e.g., cataract extraction). It typically consists of a tubular dista...
A mains electricity (AC-powered) ophthalmic instrument designed to measure the curvature of the anterior surface of the cornea, particularly for determining the presence, extent, and axis of astigmatism (an error of refraction in the eye due to the cornea b...
A non-sterile optical device intended for attachment to a multi-purpose digital medical camera to provide high-resolution focusing of digital imaging data from the fundus of the eye in fluoroscopic studies. It is intended for capturing images as a fluoresce...