A small, non-powered, noninvasive, tubular, two-way/linear connector with a Luer connection (either lock or slip) at both ends intended to connect two luminal devices (e.g., catheter, tubing, container) with each other. It may have a straight or elbow shape...
A device intended to be attached to equipment during a medical/surgical procedure and/or to a needle during drug preparation (i.e., vial venting) to prevent the transfer of microbes, particulates and aerosols while allowing passage of air/gas; its use is no...
A non-sterile device intended to be attached to equipment during a medical/surgical procedure and/or to a needle during drug preparation (i.e., vial venting) to prevent the transfer of microbes, particulates and aerosols while allowing passage of air/gas; i...
A sterile device intended to be attached to equipment during a medical/surgical procedure and/or to a needle during drug preparation (i.e., vial venting) to prevent the transfer of microbes, particulates and aerosols while allowing passage of air/gas; its u...
A non-sterile device consisting of a calibrated barrel (cylinder) with plunger intended to be used to administer (infuse) anaesthetic drugs. At the distal end of the barrel is a male Luer connector (typically a Luer-lock type) for the attachment of the fema...
A small, non-powered, noninvasive tubular device with a Luer connection (either lock or slip) at one end and an epidural catheter adapting mechanism at the other end, intended to connect an external device with a Luer connection (e.g., syringe) with an epid...
A sterile device consisting of a calibrated barrel (cylinder) with plunger intended to be used to administer (infuse) anaesthetic drugs. At the distal end of the barrel is a male Luer connector (typically a Luer-lock type) for the attachment of the female c...
A device consisting of a calibrated barrel (cylinder) with plunger intended to be used to administer (infuse) anaesthetic drugs. At the distal end of the barrel is a male Luer connector (typically a Luer-lock type) for the attachment of the female connector...
A small, non-powered, noninvasive tubular, two-way/linear connector with a Luer connection (either lock or slip) at both ends intended to connect two luminal devices (e.g., catheter, tubing, container) with each other. It may have a straight or elbow shape;...
A small, non-powered, noninvasive tubular device with a Luer connection (either lock or slip) at one end and a connection which is not designed according to ISO 80369 (standard for small-bore connectors for liquids and gases) at the other end (typically bar...
A small, non-powered, noninvasive, tubular, two-way/linear connector with a Luer connection (either lock or slip) at one end and a connection which is not designed according to ISO 80369 (standard for small-bore connectors for liquids and gases) at the othe...
A small, non-powered, noninvasive, tubular, two-way/linear connector with a Luer connection (either lock or slip) at one end and a connection which is not designed according to ISO 80369 (standard for small-bore connectors for liquids and gases) at the othe...
A small, non-powered, noninvasive, tubular, two-way/linear connector with a Luer connection (either lock or slip) at one end and a connection which is not designed according to ISO 80369 (standard for small-bore connectors for liquids and gases) at the othe...
A small, non-powered, noninvasive, tubular, two-way/linear connector with an ENFit connection (designed according to ISO 80369-3 for enteral applications) at one end and a Luer connection (either lock or slip) at the other end, intended to connect an entera...
A small, non-powered, noninvasive, tubular two-way/linear connector with an ENFit connection (designed according to ISO 80369-3 for enteral applications) at one end and a connection which is not designed according to ISO 80369 at the other end (typically ba...
A small, non-powered, noninvasive, small-bore, tubular, two-way/linear connector with connections at each end (typically barbed, bayonet, conical, threaded and/or non-Luer-slip) which are not designed according to ISO 80369 (standard for small-bore connecto...
A device intended to be placed on the Luer end of a catheter or intravenous (IV) tubing as a site of injection of substances into the in situ catheter/tubing. Some types may be designed as a Y-connector with an additional inlet (e.g., with a female Luer con...
A small, non-powered, noninvasive, small-bore, tubular, two-way/linear connector with a connection at each end (typically barbed, bayonet, conical, threaded and/or non-Luer-slip) which is not designed according to ISO 80369 (standard for small-bore connecto...
A small, noninvasive, tubular connector with a Luer connection (either lock or slip) at one end, and a hollow spike (either blunt or sharp) at the other end, intended to connect an intravenous (IV) fluid or blood bag to a fluid line or syringe for administr...
A sterile, noninvasive cap intended to be connected to the Luer connector of non-vascular tubing (e.g., pressure monitoring) to close the lumen to prevent fluid path contamination. It is a small plastic device typically of Luer-lock design; it has no additi...
A small, non-powered, noninvasive, tubular two-way/linear connector with an ENFit connection (designed according to ISO 80369-3 for enteral applications) at one end and a connection which is not designed according to ISO 80369 at the other end (typically ba...
A sterile, noninvasive cap intended to be connected to the Luer connector of a vascular catheter (e.g., haemodialysis catheter) to close the lumen, e.g., during catheter insertion. It is a small plastic device typically of Luer-lock design; it has no additi...
A small, noninvasive, tubular connector with a Luer connection (either lock or slip) at one end, and a hollow spike (either blunt or sharp) at the other end, intended to connect an intravenous (IV) fluid bag, blood bag or syringe to a fluid line for adminis...
A non-sterile device consisting of a calibrated barrel (cylinder) with plunger intended to be used for injection/withdrawal of fluids/gas (e.g., medication) to/from a medical device or the body (i.e., capable of both); it is intended for various medical app...
A sterile tubing set that is a component of a magnetic cell separation system intended to be used for the magnetic separation of target cell types or subpopulations from heterogeneous human cell preparations. It typically consists of flexible plastic tubes,...
A sterile device consisting of a calibrated barrel (cylinder) with plunger intended to be used for injection/withdrawal of fluids/gas (e.g., medication) to/from a medical device or the body (i.e., capable of both); a needle is not included. It is intended f...
A flexible, cylindrical device that typically connects a contrast imaging syringe to a patient cannula for the conduction of contrast media and flushing fluids to a patient during diagnostic radiographic procedures [e.g., angiography or computed tomography ...
A noninvasive device designed as a conduit through which a small-diameter diagnostic/interventional device(s) can be introduced into or withdrawn from a patient's vasculature while preventing backflow of blood; it might in addition be intended for urinary a...
A collection of devices intended to be used by a healthcare professional, in combination with evacuated blood collection tubes, for the routine collection of multiple blood specimens from a patient, via one venipuncture, for clinical analyses. It consists o...
A collection of sterile, noninvasive devices intended to be used by a healthcare professional, in combination with evacuated blood collection tubes and a separate blood access device (e.g., intravenous catheter), for the routine collection of multiple blood...